Kyoritsu KEW 1061 Digital True RMS Multimeter
Short Description:
key features
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements AC and AC+DC
• Fast Peak Hold response time of 250µs
AED 2,100 Original price was: AED 2,100.AED 1,950Current price is: AED 1,950. (excl.VAT)
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Kyoritsu Digital Multimeters KEW 1061
Kyoritsu 1061 digital multimeter made in Japan (kyoritsu 1061 multimeter) has the features of a professional multimeter with high accuracy, and excellent efficiency. Additionally, kew 1061 features internal memory and a USB connector for transferring data to a computer.
Kyoritsu KEW 1061 Digital True RMS Multimeter
The kew 1061 multimeter from Kyoritsu can measure direct current, resistance, capacitor, frequency, diode test, and continuity in addition to effective amounts of RMS voltage and direct current. Additionally, kew 1061 multimeter can measure temperatures between -200 and 1372 °C. This measuring instrument also has a backlight for use in dimly lit locations. Technical features alone do not distinguish this device from others; the noise filter does.
Features:
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for a double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements of AC and AC+DC
• Fast Peak Hold response time of 250µs
Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V, CAT III 1000V
• Terminal shutter to prevent incorrect test leads’ insertion in current terminals
• Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
• Large data internal memory
KEW 1061: 1,000 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
* MAX 32,767 data can be transferred.
Kyoritsu 1061 Accuracy:
The Kyoritsu 1061 digital multimeter is known for its high accuracy, with a basic accuracy of 0.02% for DC voltage measurements. This level of accuracy is essential for precise measurements, particularly in critical applications such as electronics.
AC voltage range/resolution/accuracy | , , , , |
---|---|
DC voltage range/resolution/Accuracy | , , , , , , |
AC current range/resolution/Accuracy | , , , |
DC current range/resolution/Accuracy |
10.000A/±(0.6%rdg±5dgt) ,5.0000A/±(0.6%rdg±10dgt) ,50.000mA/±(0.2%rdg±5dgt) ,500.00mA/±(0.2%rdg±5dgt) ,500.00μA/±(0.2%rdg±5dgt) ,5000.0μA/±(0.2%rdg±5dgt) |
AC Voltage Input impedance |
10MΩ<50pF [50/500/1000V] ,11MΩ<50pF [50/500mV/5V] |
AC Voltage Overload protection |
1000V rms/AC1000V DC |
DC VOLTAGE Input impedance |
100MΩ [50/500/2400mV] ,10MΩ [5/50/500/1000V] |
dc voltage overload protection |
1000V DC/1000V rms AC |
AC Current protection load |
10A Protected by A10A/1000V fuse ,440mA Protected by a 440mA/1000V fuse |
DC Current Overload protection |
10A Protected by A 10A/1000V fuse ,440mA Protected by a 440mA/1000V fuse |
Resistance Range/resolution/Accuracy |
5.0000kΩ/±(0.1%rdg+2dgt) ,5.0000MΩ/±(0.5%rdg+2dgt) ,50.000kΩ/±(0.1%rdg+2dgt) ,50.000MΩ/±(1%rdg+2dgt) ,500.00kΩ/±(0.1%rdg+2dgt) ,500.00Ω/±(0.1%rdg+2dgt) |
Capacitance Range/resolution/Accuracy |
5.000mF±(3%rdg+5dgt) ,5.000nF/±(1%rdg+5dgt) ,5.000μF/±(1%rdg+5dgt) ,50.00mF±(3%rdg+5dgt) ,50.00nF/±(1%rdg+5dgt) ,50.00μF/±(1%rdg+5dgt) ,500.0nF/±(1%rdg+5dgt) ,500.0μF/±(2%rdg+5dgt) |
Frequency range/resolution/Accuracy |
0.900 – 9.999kHz/±(0.02%rdg±1dgt) ,2.000 – 9.999Hz/±(0.02%rdg±1dgt) ,9.00 – 99.99Hz/±(0.02%rdg±1dgt) ,9.00 – 99.99kHz/±(0.02%rdg±1dgt) ,90.0 – 999.9Hz/±(0.02%rdg±1dgt) |
Temperature range/resolution/ Accuracy |
-200 – 1372ºC ±(1%rdg±1.5ºC) ,-328 – 2501.6ºF ±(1%rdg±2.0ºF) |
Power |
R6 (1.5V)×4 (Auto power off: approx. 20 minutes) |
Continuity test |
√ |
Diode test |
√ |
Duty cycle |
√ |
MIN - MAX |
√ |
Peak Hold |
√ |
True RMS |
√ |
Relative mode |
√ |
Auto Hold |
√ |
Display Hold |
√ |
specifications
Specification | Details |
---|---|
DC Voltage (DC V) | 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V |
AC Voltage (AC V) | 500.00mV/5.0000/50.000/500.00/1000.0V |
DC/AC Current (A) | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A |
Resistance (Ω) | 500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ |
Continuity Buzzer | 500.0Ω (Buzzer turns on for resistances lower than 100±50Ω) |
Diode Test | 2.4000V ±1%rdg±2dgt |
Capacitance | 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF |
Frequency | 2.000 – 9.999/9.00 – 99.99/90.0 – 999.9Hz/0.900 – 9.999/9.00 – 99.99kHz |
Duty Cycle | 10 – 90% ±1%rdg |
Temperature Measurement | -200 – 1372ºC ±1%rdg±1.5ºC |
Applicable Standards | IEC 61010-1 CAT IV 600V, CAT III 1000V, Pollution Degree 2 |
Power Source | R6 (1.5V) × 4 (Auto power off: approx. 20 minutes) |
Dimensions | 192(L) × 90(W) × 49(D) mm |
Weight | Approx. 560g (including batteries) |
2 reviews for Kyoritsu KEW 1061 Digital True RMS Multimeter
Clear filtersYou must be logged in to post a review.
You may Also like...
Kyoritsu KEW 1062 Digital Multimeter
In stock
Fluke 289 TRMS Logging Multimeter with TrendCapture
In stock
Call for Price
Maria –
An application device
Amira Ali –
Engineer electrical solutions provided by this shop are innovative and efficient.