Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit
Short Description:
The Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit features four powerful new diagnostic functions through the Fluke Connect Measurements app.
Call for Best Price 00971(04) 447 6031 00971(04) 344 9868
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 1587/MDT FC Kit
The Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit is an essential toolset for professionals tasked with diagnosing and maintaining motors and drives. This comprehensive kit includes the Fluke 1587 FC 2-in-1 Insulation Digital Multimeter (DMM), the Fluke i400 Current Clamp, and the Fluke 9040 Phase Rotation Indicator. Together, these tools provide a robust solution for a wide range of electrical testing and troubleshooting tasks.
Components of the Kit
The Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit is a comprehensive solution for professionals in the electrical maintenance and troubleshooting industry. With its combination of insulation testing, current measurement, and phase rotation indication, this kit provides all the tools necessary for efficient and safe diagnostics of motors and drives.
Fluke 1587 FC 2-in-1 Insulation DMM
The Fluke 1587 FC Insulation DMM combines a full-featured digital multimeter with a powerful insulation tester, providing a versatile tool for motor and drive maintenance.
- Insulation Testing: Perform tests at voltages of 50 V, 100 V, 250 V, 500 V, and 1000 V, measuring insulation resistance from 0.01 MΩ to 2.0 GΩ and 0.1 MΩ to 600 MΩ.
- Pl/DAR Measurements: Identify moisture and contamination issues with timed ratio tests and TrendItâ„¢ graphs.
- Memory Storage: Store results through the Fluke Connect Measurements app, eliminating manual recording and reducing errors.
- Temperature Compensation: Establish accurate baselines with temperature-compensated readings.
- VFD Low-Pass Filter: Ensure accurate motor drive measurements.
- Comprehensive Measurements: Includes frequency, capacitance, diode test, temperature, Min/Max, AC/DC voltage, DC millivolts, AC/DC milliamps, resistance (0.1 Ω to 50 MΩ), and continuity.
- Safety and Convenience: Features auto power off, auto-discharge of capacitive voltage, and comes with a three-year warranty, remote probe, test leads, alligator clips, K-type thermocouple, and a hard case.
Fluke i400 AC Current Clamp
The Fluke i400 AC Current Clamp allows you to measure AC current safely and accurately without breaking the circuit.
- Current Measurement: Measures from 1A AC to 400 A AC with a 1 mA/Amp output for easy reading.
- Safety Ratings: Rated CAT III 1000 V and CAT IV 600 V for user protection.
- Compact Design: Designed for maximum utility in a compact shape with a maximum conductor diameter of Ø 32 mm.
Fluke 9040 Phase Rotation Indicator
The Fluke 9040 Phase Rotation Indicator is essential for determining the phase rotation in three-phase systems, ensuring correct motor connection and operation.
- Field Rotation and Phase Sequence: Easily determine field rotation and phase sequence with a large display.
- Three-Phase Indication: Provides indication for all three phases.
- Safety Rating: Rated CAT III 600 V for overvoltage protection.
Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit specifications:
DC and AC Current Measurement:
- AC 45 Hz to 1000 Hz
- Range:400 mA
- Resolution:0.1 mA
- Accuracy ±(% of Rdg+Counts):±(1.5% + 2)
- Burden voltage (Typical):2 mV/mA
- Range:60 mA
- Resolution:0.01 mA
- Accuracy ±(% of Rdg+Counts):±(1.5% + 2)
- Burden voltage (Typical):2 mV/mA
DC:
- Range:400 mA
- Resolution:0.1 mA
- Accuracy ±(% of Rdg+Counts):±(0.2% + 2)
- Burden voltage (Typical):2 mV/mA
- Range:60 mA
- Accuracy ±(% of Rdg+Counts):±(0.2% + 2)
- Burden voltage (Typical):2 mV/mA
Ohms Measurement:
- Overload protection :1000 V rms or dc
- Open circuit test voltage :<8.0 V dc
- Short circuit current :Short circuit current
specifications
AC Voltage Measurement | |||||||
Range | Resolution | Accuracy | |||||
---|---|---|---|---|---|---|---|
600.0 mV | 0.1 mV | 50 Hz to 60 Hz ±(1% + 3) | 60 Hz to 5000 Hz ±(2% + 3) | ||||
6.000 V | 0.001 V | 50 Hz to 60 Hz ±(1% + 3) | 60 Hz to 5000 Hz ±(2% + 3) | ||||
60.00 V | 0.01 V | 50 Hz to 60 Hz ±(1% + 3) | 60 Hz to 5000 Hz ±(2% + 3) | ||||
600.0 V | 0.1 V | 50 Hz to 60 Hz ±(1% + 3) | 60 Hz to 5000 Hz ±(2% + 3)¹ | ||||
1000 V | 1 V | 50 Hz to 60 Hz ±(2% + 3) | 60 Hz to 5000 Hz ±(2% + 3)¹ | ||||
¹ 1 kHz bandwidth | |||||||
Low-Pass Filter Voltage | |||||||
Range | Resolution | Accuracy | |||||
600.0 mV | 0.1 mV | 50 Hz to 60 Hz ±(1% + 3) | 60 Hz to 400 Hz ±(2% + 3) | ||||
6.000 V | 0.001 V | 50 Hz to 60 Hz ±(1% + 3) | 60 Hz to 400 Hz ±(2% + 3) | ||||
60.00 V | 0.01 V | 50 Hz to 60 Hz ±(1% + 3) | 60 Hz to 400 Hz ±(2% + 3) | ||||
600.0 V | 0.1 V | 50 Hz to 60 Hz ±(1% + 3) | 60 Hz to 400 Hz ±(2% + 3) | ||||
1000 V | 1 V | 50 Hz to 60 Hz ±(2% + 3) | 60 Hz to 400 Hz ±(2% + 3) | ||||
DC Voltage Measurement | |||||||
Range | Resolution | Accuracy ±(% of Rdg + Counts) | |||||
6.000 V dc | 0.001 V | ±(0.09% + 2) | |||||
60.00 V dc | 0.01 V | ±(0.09% + 2) | |||||
600.0 V dc | 0.1 V | ±(0.09% + 2) | |||||
1000 V dc | 1 V | ±(0.09% + 2) | |||||
Input impedance: 10 MΩ (nominal), <100 pF Normal mode rejection ratio: >60 dB @ 50 Hz or 60 Hz Common mode rejection ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) Accuracies apply to ± 100% of range |
|||||||
DC Millivolts Measurement | |||||||
Range | Resolution | Accuracy ±(% of Rdg + Counts) | |||||
600.0 mVdc | 0.1 mV | ±(0.1% + 1) | |||||
DC and AC Current Measurement | |||||||
Range | Resolution | Accuracy ±(% of Rdg+Counts) | |||||
400 mA (AC 45 Hz to 1000 Hz) | 0.1 mA | ±(1.5% + 2)¹ | |||||
60 mA (AC 45 Hz to 1000 Hz) | 0.01 mA | ±(1.5% + 2)¹ | |||||
400 mA (DC) | 0.1 mA | ±(0.2% + 2) | |||||
60 mA (DC) | 0.01 mA | ±(0.2% + 2) | |||||
¹ 1 kHz bandwidth Burden voltage (Typical): 2 mV/mA Overload: 600 mA for 2 minutes maximum Fuse protection for mA input: 0.44 mA, 1000 V, IR 10 kA AC conversion: Inputs are ac-coupled and calibrated to the rms value of sine wave input. Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3. |
|||||||
Ohms Measurement | |||||||
Range | Resolution | Accuracy ±(% of Rdg + Counts)¹ | |||||
600.0 Ω | 0.1 Ω | ±(0.9% + 2) | |||||
6.000 kΩ | 0.001 kΩ | ±(0.9% + 2) | |||||
60.00 kΩ | 0.01 kΩ | ±(0.9% + 2) | |||||
600.0 kΩ | 0.1 KΩ | ±(0.9% + 2) | |||||
6.000 MΩ | 0.001 MΩ | ±(0.9% + 2) | |||||
50.0 MΩ ² | 0.01 MΩ | ±(1.5% + 3) | |||||
Overload protection: 1000 V rms or dc Open circuit test voltage: <8.0 V dc Short circuit current: <1.1 mA |
|||||||
Diode Test | |||||||
Diode Test Indication | Accuracy ±(% of Rdg + Counts) | ||||||
Display voltage drop: 0.6 V at 1.0 mA nominal test current | ±(2% + 3) | ||||||
Continuity Test | |||||||
Continuity Indication | Specifications | ||||||
Continuous audible tone for test resistance below 25 Ω and off above 100 Ω | Max Reading: 1000 Ω, Open circuit voltage: <8.0 V, Short circuit current: 1.0 mA typical, Overload protection: 1000 V rms, Response time: >1 m sec | ||||||
Frequency Measurement | |||||||
Range | Resolution | Accuracy ±(% of Rdg + Counts) | |||||
99.99 Hz | 0.01 Hz | ±(0.1% + 1) | |||||
999.9 Hz | 0.1 Hz | ±(0.1% + 1) | |||||
9.999 kHz | 0.001 kHz | ±(0.1% + 1) | |||||
99.99 kHz | 0.01 kHz | ±(0.1% + 1) | |||||
Frequency Counter Sensitivity: V ac Sensitivity (RMS Sine Wave) 600.0 mV: 5 Hz to 20 kHz – 100.0 mV, 20 kHz to 100 kHz – 150.0 mV 6.0 V: 5 Hz to 20 kHz – 1.0 V, 20 kHz to 100 kHz – 1.5 V 60.0 V: 5 Hz to 20 kHz – 10.0 V, 20 kHz to 100 kHz – 36.0 V 600.0 V: 5 Hz to 20 kHz – 100.0 V 1000.0 V: 5 Hz to 20 kHz – 300.0 V Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy. Usable to 100 kHz with full scale input |
|||||||
Capacitance | |||||||
Range | Resolution | Accuracy ±(% of Rdg + Counts) | |||||
1000 nF | 1 nF | ±(1.2% + 2) | |||||
10.00 μF | 0.01 μF | ±(1.2% + 2) | |||||
100.0 μF | 0.1 μF | ±(1.2% ±90 counts) | |||||
9999 μF | 1 μF | ±(1.2% ±90 counts) | |||||
Temperature Measurement | |||||||
Range | Resolution | Accuracy ±(% of Rdg + Counts) | |||||
-40 °C to 537 °C | 0.1 °C | ±(1% + 10 counts) | |||||
-40 °F to 998 °F | 0.1 °F | ±(1% + 18 counts) | |||||
Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument | |||||||
Insulation Specifications | |||||||
Measurement Range | 0.01 MΩ to 2 GΩ | ||||||
Test Voltages | 50, 100, 250, 500, 1000 V | ||||||
Test Voltage Accuracy | +20%, -0% | ||||||
Short-Circuit Test Current | 1 mA nominal | ||||||
Auto Discharge | Discharge time <0.5 second for C = 1 μF or less | ||||||
Live Circuit Detection | Inhibit test if terminal voltage > 30 V prior to initialization of test | ||||||
Maximum Capacitive Load | Operable with up to 1 μF load | ||||||
General Specifications | |||||||
Maximum Voltage Applied to Any Terminal and Common | 1000 V | ||||||
Storage Temperature | -40 °C to 60 °C (-40 °F to 140 °F) | ||||||
Operating Temperature | -20 °C to 55 °C (-4 °F to 131 °F) | ||||||
Temperature Coefficient | 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F) | ||||||
Relative Humidity | Noncondensing 0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F) 0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F) 0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F) |
||||||
Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | ||||||
Radio Frequency Communication | 2.4 GHz ISM Band | ||||||
Radio Frequency Certification | FCC: T68-FBLE, IC: 6627A-FBLE | ||||||
Electromagnetic Compatibility | |||||||
International | IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected. |
||||||
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
||||||
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | ||||||
Enclosure Protection | IEC 60529: IP40 (non-operating) | ||||||
Safety | |||||||
IEC 61010-1 | Pollution Degree 2 | ||||||
IEC 61010-2-033 | CAT IV 600 V / CAT III 1000 V | ||||||
Batteries | Four AA batteries (NEDA 15A or IEC LR6) | ||||||
Battery Life | Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. | ||||||
Size (H x W x L) | 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) | ||||||
Weight | 550 g (1.2 lb) | ||||||
Altitude | Operating: 2000 m Storage: 12,000 m |
||||||
Over-Range Capability | 110% of range except for capacitance which is 100% | ||||||
Frequency Overload Protection | <107 V Hz | ||||||
Fuse Protection for mA Input | 0.44A, 1000 V, IR 10 kA | ||||||
Fluke i400 AC Current Clamp | |||||||
Nominal Current Range | 400 A | ||||||
Continuous Current Range | 1 A – 400 A | ||||||
Maximum Non-Destructive Current | 1000 A | ||||||
Lowest Measurable Current | 1 A | ||||||
Basic Accuracy | 2% + 0.06 A (45-400 Hz) | ||||||
Usable Frequency | 5 Hz – 20 kHz | ||||||
Output Level(s) | 1 mA/A | ||||||
Safety Specifications | |||||||
Safety | CAT IV 600 V, CAT III, 1000 V | ||||||
Maximum Voltage | 1000 V AC rms from earth to ground, in compliance with EN61010 | ||||||
Mechanical and General Specifications | |||||||
Warranty | 1 year | ||||||
Maximum Conductor Diameter | 32 mm (1.25 in) | ||||||
Maximum Conductor Size (Busbar) | 750 MCM | ||||||
Output Cable Length | 1.5 m (59 in) | ||||||
Shrouded Banana Plugs | Yes | ||||||
Fluke 9040 Phase Rotation Indicator | |||||||
Voltage Range | 40-700 V | ||||||
Frequency Range | 15-400 Hz | ||||||
Operating Timer | Continuous | ||||||
Environmental Specifications | |||||||
Operating Temperature | 0 °C to 40 °C | ||||||
Dust/Water Resistance | IP 40 | ||||||
Safety Specifications | |||||||
Electrical Safety | EN 61010, EN 61557“`html -7 |
Overvoltage Category | CAT III 600 V, CAT IV 300 V | ||||
Mechanical and General Specifications | |||||||
Size | 124 x 61 x 27 mm | ||||||
Weight | 200 g | ||||||
Power Supply | From unit under test |