Fluke 1630-2 FC Earth Ground Clamp
Short Description:
- Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes.
- AC Leakage Current Measurement: Identify AC leakage without disconnecting your earth ground stake from the grounding system
- Rugged: Heavy-duty clamp jaw stays in alignment and calibration on tough sites
- Logging measurement: Saves up to 32,760 measurements in memory
Product purchase
AED 7,500 Original price was: AED 7,500.AED 7,400Current price is: AED 7,400. (excl.VAT)
2 in stock
19
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 1630-2 FC Earth Ground Clamp
The Fluke 1630-2 FC Earth Ground Clamp is an electrical testing tool that is used to evaluate ground resistance in electrical systems. Fluke Corporation, a well-known maker of electronic test and measurement equipment, created it.
Using the dual-clamp jaw, the Fluke 1630-2 FC clamp monitors earth ground loop resistances for multi-grounded systems. This test method eliminates the risky and time-consuming task of disconnecting parallel grounds, as well as the process of locating acceptable places for supplementary test stakes. You can also conduct ground tests in previously challenging locations, such as inside buildings, on electrical pylons, or anywhere you don’t have access to soil to install supplemental test stakes.
The Fluke 1630 2 fc Earth Ground Clamp features:
- Earth Ground Resistance Measurement: The clamp is used to check whether the grounding system fulfills safety standards and provides adequate protection against electrical problems.
- True RMS Measurement: To offer precise measurements of both sinusoidal and non-sinusoidal waveforms, the gadget employs True RMS (Root Mean Square) technology.
- Wireless connection: The “FC” in the product name stands for “Fluke Connect,” indicating that the clamp has wireless connection capabilities. It may send measurement data to a smartphone or other Bluetooth-enabled device, allowing for remote monitoring and data logging.
- big Jaw Opening: Because the clamp has a big jaw opening, it may clamp around larger ground conductors or many smaller conductors at the same time.
- Display and Data Storage: The Fluke 1630-2 FC has an easy-to-read digital display that displays measurement values. It may also be capable of storing measurement data internally or via connected devices.
- Detect alternating current leakage currents without removing the earth ground stake from the grounding system–ideal for system troubleshooting.
- Even in harsh industrial conditions, the rugged heavy-duty clamp jaw maintains alignment and calibration.
More information about the earth resistance tester price can be found on MME’s website.
Specifications Fluke 1630-2 FC Earth Ground Clamp :
- Maximum voltage to earth ground: 1000 V
- Battery type: AA alkaline IEC/EN LR6 (x4)
- Frequency range: 40 Hz to 1 kHz
- Ingress protection: IEC/EN 60529: IP30 with jaw closed
- Operating temperature : -10 °C to + 50 °C
- Reference temperature : 23 °C ±5 °C (73 °F ±9 °F)
- Data logging capacity: Minimum of 32,760 measurements
- Conductor size: 40 mm (1.57 in) approximately
- Dimensions (L x W x H) : 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)
- Weight: 880g (31 oz)
- Range Earth Ground Loop Resistance: 0.025 – 1500 Ω
- Range Earth ground leakage current mA: 0.200 mA – 39.99 A
Specifications
Feature | Description |
---|---|
Maximum voltage to earth ground | 1000 V |
Battery type | AA alkaline IEC/EN LR6 (x4) |
Battery life | More than 15 hours* * In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off |
Frequency range | 40 Hz to 1 kHz |
Ingress protection | IEC/EN 60529: IP30 with jaw closed |
LCD Digital reading | 9999 counts |
Refresh rate | 4 per second |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -20 °C to +60 °C |
Operating humidity | Non condensing (<10 °C) (< 50 °F) ≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F]) ≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F]) ≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F]) (Non condensing) |
Operating altitude | 2000 m (6561 feet) |
Storage altitude | 12 000 m (39,370 feet) |
Reference temperature | 23 °C ±5 °C (73 °F ±9 °F) |
Temperature coefficient | 0.15% x (specified accuracy)/°C (<18 °C or >28 °C [<64.4 °F or >82.4 °F]) |
Overload indication | OL |
Data logging capacity | Minimum of 32,760 measurements |
Data logging interval | 1 second to 59 minutes and 59 seconds |
Display Reading Specification with Standard Loop Resistance
Input (Ω) | Minimum | Maximum |
---|---|---|
0.474 | 0.417 | 0.531 |
0.5 | 0.443 | 0.558 |
10 | 9.55 | 10.45 |
100 | 96 | 104 |
Safety
Feature | Description |
---|---|
General | IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1 |
Measurement | IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V |
Current clamp for leakage current measurements | IEC/EN 61557-13: Class 2, ≤30 A/m |
Resistance to earth | IEC/EN 61557-5 |
Effectiveness of the protective measures | IEC/EN 61557-16 |
Electromagnetic compatibility (EMC) | International IEC/EN 61326-1: Portable Electromagnetic Environment CISPR 11: Group 1, Class B, IEC/EN 61326-2-2 |
Korea (KCC) | Class A equipment (Industrial Broadcast & Communications Equipment) |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
Wireless Radio
Feature | Description |
---|---|
Frequency range | 2412 MHz to 2462 MHz |
Output power | <10 mW |
Radio frequency certification | FCC ID:T68-FBLE IC:6627A-FBLE |
General Specifications
Feature | Description |
---|---|
Conductor size | 40 mm (1.57 in) approximately |
Dimensions (L x W x H) | 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in) |
Weight | 880g (31 oz) |
Warranty | One year |
Earth Ground Loop Resistance
Range | Accuracy ± (% of reading + Ω) |
---|---|
0.025 Ω to 0.249 Ω | 1.5% + 0.02 Ω |
0.250 Ω to 0.999 Ω | 1.5% + 0.05 Ω |
1.000 Ω to 9.999 Ω | 1.5% + 0.10 Ω |
10.00 Ω to 49.99 Ω | 1.5% + 0.30 Ω |
50.00 Ω to 99.99 Ω | 1.5% + 0.50 Ω |
100.0 Ω to 199.9 Ω | 3.0% + 1.0 Ω |
200.0 Ω to 399.9 Ω | 5.0% + 5.0 Ω |
400 Ω to 599 Ω | 10.0% + 10 Ω |
600 Ω to 1500 Ω | 20.00% |
Loop resistance with no inductance, conductor centered and perpendicular to jaw
Earth Ground Leakage Current (mA)
Autorange 50/60 Hz, True rms, crest factor CF ≤3
Range | Resolution | Accuracy ± (% of reading + mA) |
---|---|---|
0.200 mA to 3.999 mA | 1 μA | 2.0% + 0.05 mA |
4.00 mA to 39.99 mA | 10 μA | 2.0% + 0.03 mA |
40.0 mA to 399.9 mA | 100 μA | 2.0% + 0.3 mA |
0.400 A to 3.999 A | 1 mA | 2.0% + 3 mA |
4.00 A to 39.99 A | 10 mA | 2.0% + 30 mA |
Applies to signal frequency 40 Hz to 1 kHz with filter set to OFF 40 Hz to 70 Hz with filter set to ON
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Fluke 1630-2 FC Earth Ground Clamp
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
MAYA –
The variety of products is fantastic.