Fluke 283 FC Digital Multimeter

Short Description:

The Fluke 283 FC is a robust and reliable tool for technicians working with high-voltage DC systems. Its safety ratings, accurate measurement capabilities, and wireless connectivity make it an excellent solar PV system maintenance and troubleshooting choice.

  • 1000 V AC volts
  • 1500 V DC volts
  • 600.0 mV AC
Product purchase
SKU: 103307

Call for Best Price 00971(04) 447 6031 00971(04) 344 9868

20 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
Description

Buy Fluke 283 FC

The Fluke 283 FC True-RMS Wireless Multimeter is engineered for troubleshooting in high-voltage DC environments, particularly solar installations up to 1500 V DC. This multimeter helps technicians test voltage, resistance, continuity, and more accurately and safely. Its CAT III 1500 V / CAT IV 1000 V safety ratings ensure user protection in demanding electrical environments.

The Fluke 283 FC offers several functionalities designed to enhance testing and troubleshooting. Here are some of its key features:

  • High Voltage Measurement: Designed for environments up to 1500V DC.
  • True-RMS Measurements: Provides accurate AC voltage and current measurements, even with non-linear signals.
  • Wireless Connectivity: Allows convenient data transmission and remote monitoring, eliminating tangled wires. Measurements can be saved and logged to internal memory and viewed on a mobile device via Fluke Connect™.
  • User-Defined Limit Gauge: Helps make quick go/no-go decisions.
  • Visual and Audio Indicators: Polarity indicators help prevent accidental module wiring issues.
  • Simultaneous Voltage and Current Measurement: When used with the A283 FC wireless current clamp, this device can measure voltage and current simultaneously and automatically calculate VA power.
  • Unique Multimeter Self-Check: Ensures the meter is ready for testing.

Beyond its core functionalities, the Fluke 283 FC includes features that enhance usability and efficiency. These include:

  • Real-time clock: Each measurement can be time- and date-stamped for accurate recordkeeping.
  • Logging and saving: The multimeter has internal memory to save and log measurements, which can then be easily transferred to
    Fluke Connect for further analysis. Additionally, you have the flexibility to customize logging durations and intervals.
  • Included Accessories: Comes with the Fluke 283 FC TRMS Wireless Digital Multimeter, a283 FC 60A TRMS Wireless AC/DC Current Clamp,
    This package includes a solar MC4 test Lead set, TL175-HV TwistGuard™ Silicone test leads, a premium carrying case, and a magnetic hanging strap.

Fluke 283 FC Specifications

The Fluke 283 FC Digital Multimeter measures AC voltage up to 1,000 V and DC voltage up to 1,500 V.

Function Range Resolution Accuracy
AC volts[1] 6.000 V 0.001 V 1.0 % + 3
60.00 V 0.01 V (45 Hz to 500 Hz)
600.0 V 0.1 V 2.0 % + 3
1000 V 1 V (500 Hz to 1 kHz)
DC volts 6.000 V 0.001 V 0.09 % + 3
60.00 V 0.01 V
600.0 V 0.1 V
1500 V 1 V 0.15 % + 2
AC mV[1] 600.0 mV 0.1 mV 1.0% + 3 (45 Hz ~ 500 Hz)
2.0% + 3 (500 Hz ~ 1000 Hz)
DC mV 600.0 mV 0.1 mV 0.09 % + 2
Continuity 600 Ω 1 Ω
Resistance 600.0 Ω 0.1 Ω 0.5 % + 4
6.000 kΩ 0.001 kΩ
60.00 kΩ 0.01 kΩ
600.0 kΩ 0.1 kΩ
6.000 MΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 4
Capacitance 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF 1 μF 10 % typical
Frequency 99.99 Hz 0.01 Hz 0.1 % + 2
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
AC VA (45 Hz ~ 500 Hz)[1] 360.0 VA 0.1 VA 2 % + 1.0 VA
3.600 kVA 0.001 kVA 2 % + 0.01 kVA
36.00 kVA 0.01 kVA 2 % + 0.1 kVA
60.00 kVA 0.01 kVA 2 % + 0.15 kVA
DC VA[1] 360.0 VA 0.1 VA 2 % + 1.0 VA
3.600 kVA 0.001 kVA 2 % + 0.01 kVA
36.00 kVA 0.01 kVA 2 % + 0.1 kVA
90.00 kVA 0.01 kVA 2 % + 0.25 kVA
Min-max avg For DC functions, accuracy is the specified accuracy of the measurement function ± 12 counts for changes longer than 350 ms in duration.
For AC functions, accuracy is the specified accuracy of the measurement function ± 40 counts for changes longer than 900 ms in duration.
[1] <1% range, unspecified
Environmental specifications
Operating temperature -10 °C to 60 °C
Storage temperature -30 °C to +70 °C
Humidity (without condensation) 0 % to 90 %, 10 °C to 30 °C
0 % to 75 %, 30 °C to 40 °C
0 % to 45 %, 40 °C to 60 °C
Warranty and Protection
Electromagnetic compatibility IEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A
Overvoltage category CAT III 1500 V, CAT IV 1000 V
Agency approvals ETL (AMER and EMEA), CSA (APAC), CE, UK CA
Drop test 2 meter (6.5 ft) drop test
Ingress protection IP52
Warranty Limited lifetime
Mechanical and general specifications
Counts 6000
Size 22.5 cm x 10.5 cm x 5.7 cm (8.8 in x 4.1 in x 2.2 in)
Weight 0.7 kg (1.5 lb)
Battery life > 150 hours typical, without backlight (Alkaline, 3 AA)
> 100 hours typical when connected to wireless current clamp (Alkaline, 3 AA)

Buy the Fluke 283 FC Digital Multimeter, a robust and reliable tool for technicians with high-voltage DC systems. Its safety ratings, accurate measurement capabilities, and wireless connectivity make it an excellent solar PV system maintenance and troubleshooting choice.

Additional information
DC Voltage Range/Resolution/Accuracy

6.000 V

,

0.001 V

,

0.09 % + 3
60.00 V

,

0.01 V

,

0.09 % + 3
600.0 V

,

0.1 V

,

0.09 % + 3
1500 V

,

1 V

,

0.15 % + 2

AC Voltage Range/Resolution/Accuracy

6.000 V

,

0.001 V

,

1.0 % + 3 (45 Hz to 500 Hz)
60.00 V

,

0.01 V

,

1.0 % + 3 (45 Hz to 500 Hz)
600.0 V

,

0.1 V

,

2.0 % + 3 (500 Hz to 1 kHz)
1000 V

,

1 V

,

2.0 % + 3 (500 Hz to 1 kHz)

AC mV Voltage Range/Resolution/Accuracy

600.0 mV

,

0.1 mV

,

1.0% + 3 (45 Hz ~ 500 Hz), 2.0% + 3 (500 Hz ~ 1000 Hz)

DC mV Voltage Range/Resolution/Accuracy

600.0 mV

,

0.1 mV

,

0.09 % + 2

Continuity

600 Ω

,

1 Ω

Resistance

600.0 Ω

,

0.1 Ω

,

0.5 % + 4
6.000 kΩ

,

0.001 kΩ

,

0.5 % + 4
60.00 kΩ

,

0.01 kΩ

,

0.5 % + 4
600.0 kΩ

,

0.1 kΩ

,

0.5 % + 4
6.000 MΩ

,

0.001 MΩ

,

0.5 % + 4
50.00 MΩ

,

0.01 MΩ

,

1.5 % + 4

Capacitance

1000 nF

,

1 nF

,

1.2 % + 2
10.00 μF

,

0.01 μF

,

1.2 % + 2
100.0 μF

,

0.1 μF

,

1.2 % + 2
9999 μF

,

1 μF

,

10 % typical

Frequency

99.99 Hz

,

0.01 Hz

,

0.1 % + 2
999.9 Hz

,

0.1 Hz

,

0.1 % + 2
9.999 kHz

,

0.001 kHz

,

0.1 % + 2
99.99 kHz

,

0.01 kHz

,

0.1 % + 2

Operating temperature

-10 °C to 60 °C

Storage temperature

-30 °C to +70 °C

Electromagnetic compatibility

IEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A

Overvoltage category

CAT III 1500 V, CAT IV 1000 V

Agency approvals

ETL (AMER and EMEA), CSA (APAC), CE, UK CA

Drop test

2 meter (6.5 ft) drop test

Ingress protection

IP52

Dimentions

22.5 cm x 10.5 cm x 5.7 cm (8.8 in x 4.1 in x 2.2 in)

Weight

0.7 kg (1.5 lb)

Counts

6000

Datasheet

Datasheet

Datasheet

Datasheet

Specifications

Specifications

Function Range Resolution Accuracy
AC volts[1] 6.000 V 0.001 V 1.0 % + 3
60.00 V 0.01 V (45 Hz to 500 Hz)
600.0 V 0.1 V 2.0 % + 3
1000 V 1 V (500 Hz to 1 kHz)
DC volts 6.000 V 0.001 V 0.09 % + 3
60.00 V 0.01 V
600.0 V 0.1 V
1500 V 1 V 0.15 % + 2
AC mV[1] 600.0 mV 0.1 mV 1.0% + 3 (45 Hz ~ 500 Hz)
2.0% + 3 (500 Hz ~ 1000 Hz)
DC mV 600.0 mV 0.1 mV 0.09 % + 2
Continuity 600 Ω 1 Ω
Resistance 600.0 Ω 0.1 Ω 0.5 % + 4
6.000 kΩ 0.001 kΩ
60.00 kΩ 0.01 kΩ
600.0 kΩ 0.1 kΩ
6.000 MΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 4
Capacitance 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF 1 μF 10 % typical
Frequency 99.99 Hz 0.01 Hz 0.1 % + 2
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
AC VA (45 Hz ~ 500 Hz)[1] 360.0 VA 0.1 VA 2 % + 1.0 VA
3.600 kVA 0.001 kVA 2 % + 0.01 kVA
36.00 kVA 0.01 kVA 2 % + 0.1 kVA
60.00 kVA 0.01 kVA 2 % + 0.15 kVA
DC VA[1] 360.0 VA 0.1 VA 2 % + 1.0 VA
3.600 kVA 0.001 kVA 2 % + 0.01 kVA
36.00 kVA 0.01 kVA 2 % + 0.1 kVA
90.00 kVA 0.01 kVA 2 % + 0.25 kVA
Min-max avg For DC functions, accuracy is the specified accuracy of the measurement function ± 12 counts for changes longer than 350 ms in duration.
For AC functions, accuracy is the specified accuracy of the measurement function ± 40 counts for changes longer than 900 ms in duration.
[1] <1% range, unspecified
Environmental specifications
Operating temperature -10 °C to 60 °C
Storage temperature -30 °C to +70 °C
Humidity (without condensation) 0 % to 90 %, 10 °C to 30 °C
0 % to 75 %, 30 °C to 40 °C
0 % to 45 %, 40 °C to 60 °C
Warranty and Protection
Electromagnetic compatibility IEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A
Overvoltage category CAT III 1500 V, CAT IV 1000 V
Agency approvals ETL (AMER and EMEA), CSA (APAC), CE, UK CA
Drop test 2 meter (6.5 ft) drop test
Ingress protection IP52
Warranty Limited lifetime
Mechanical and general specifications
Counts 6000
Size 22.5 cm x 10.5 cm x 5.7 cm (8.8 in x 4.1 in x 2.2 in)
Weight 0.7 kg (1.5 lb)
Battery life > 150 hours typical, without backlight (Alkaline, 3 AA)
> 100 hours typical when connected to wireless current clamp (Alkaline, 3 AA)