Fluke CNX 3000 HVAC System

(3 customer reviews)

Short Description:

The Fluke CNX 3000 HVAC System lets you work on electrical panels faster, safer, easier with remote current and temperature modules.

Product purchase
SKU: 3183 Categories: ,
Brand:Fluke

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

14 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE

Fluke CNX 3000 HVAC System

The Fluke CNX 3000 HVAC System provides a comprehensive solution for measuring all common electrical and temperature parameters. This advanced system, part of the Fluke team of wireless troubleshooting tools, enhances efficiency and safety for HVAC professionals by enabling remote monitoring and data collection.

Fluke CNX3000 Key Features

The Fluke CNX 3000 HVAC System consists of the CNX 3000 Wireless Multimeter, the CNX t3000 K-Type Wireless Temperature Module, and the CNX a3000 AC Wireless Current Clamp Module, all designed to meet the demanding needs of modern HVAC measurement tasks.

CNX 3000 Wireless Multimeter

The CNX 3000 Wireless Multimeter offers robust functionality, including:

  • True RMS Measurements: Accurate AC and DC voltage measurements up to 1000V and current measurements with 0.01 mA resolution.
  • Comprehensive Testing Capabilities: Includes continuity, resistance, diode test, capacitance, and frequency measurements.
  • MIN/MAX Recording: Captures and records minimum, maximum, and average values for detailed analysis.
  • Safety and Durability: Rated CAT III 1000 V; CAT IV 600 V; IP54, ensuring reliable performance in challenging environments.

CNX t3000 K-Type Wireless Temperature Module

The CNX t3000 K-Type Wireless Temperature Module is designed for precise temperature measurements, featuring:

  • Wide Temperature Range: Measures temperatures from -200 °C to 1372 °C with ± 0.5% accuracy.
  • Extensive Memory: Capable of recording up to 65,000 readings, providing a thorough record of temperature data.
  • Clear Display: Backlit LCD display for easy viewing in various lighting conditions.
  • Durability: IP42 rating with the thermocouple attached, ensuring reliable use in diverse environments.

CNX a3000 AC Wireless Current Clamp Module

The CNX a3000 AC Wireless Current Clamp Module is designed for precise current measurements, featuring:

  • True RMS AC Current Measurements: Measures up to 400 A with 2% accuracy up to 100Hz and 2-1/2% accuracy up to 500Hz.
  • Extensive Memory: Capable of recording up to 65,000 readings, providing a thorough record of current data.
  • Clear Display: Backlit LCD display for easy viewing in various lighting conditions.
  • Safety and Durability: Rated CAT III 600 V; IP30, ensuring reliable use in diverse environments.

Advanced Wireless System

The CNX wireless system enhances productivity and safety by allowing simultaneous tracking of up to 10 measurement modules. Results can be sent to a PC for detailed analysis, reducing the need for manual data collection.

  • Remote Monitoring: Connect the CNX a3000 AC Wireless Current Clamp Module to your test point and view the results up to 20 meters away on the CNX Wireless Multimeter. This feature saves time by minimizing the need to move around to collect multiple measurements.
  • Multi-Point Measurements: Use multiple modules to take measurements on three-phase systems simultaneously. This flexibility allows for more comprehensive monitoring and data collection.
  • Standalone or System Use: The modules can be used individually as standalone measurement tools or combined with other CNX modules for a complete measurement system.
  • Enhanced Safety: View readings from a safe distance, reducing the risk of exposure to hazardous conditions. This is particularly useful for taking readings on moving machinery, where only the measurement module is in harm’s way.
  • Data Logging: The CNX remote modules can capture up to 65,000 sets of time-stamped min/max/avg readings, which can be transferred to a PC using the optional adapter. This eliminates the need for manual data recording.

similar product

if you are looking for a similar product visit best fluke multimeter.

Fluke CNX 3000 HVAC System Specifications:

  • Range: 400.0 A
  • Resolution: 0.1 A
  • Accuracy: 400.0 A:2 % ± 5 digits (10 Hz to 100 Hz)
    2.5 % ± 5 digits (100 Hz to 500 Hz)
  • Inrush: Max displayed reading: 999.9A
  • Crest factor (50 Hz/60 Hz): 3.0 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 %
  • Display : 3-1/2 digits, LCD w/backlight
  • Log rate/interval: 1-sec minimum/adjustable by PC
  • Battery type: 2 AA, NEDA 15 A, IEC LR6
  • Battery life: 400 hours
  • Memory: Record up to 65,000 readings
  • RF communications: 2.4 GHZ ISM Band
  • RF communication range: 20 Meters
  • Operating temperature: -10 °C to +50 °C
  • Storage temperature: -40 °C to +60 °C
  • Operating humidity : 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
  • EMC : EN 61326-1:2006
  • Safety compliance: EN/IEC 61010-1-30:2010 to 600 V Measurement Category (CAT) III
    EN/IEC 61010-2-030:2010
    EN/IEC 61010-2-032:2002

datasheet

Data Sheet

Specifications

AC Voltage

Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz 600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3
2.0 % + 3
500 Hz to 1 kHz 600.0 mV
6.000 V
0.1 mV
0.001 V
2.0 % + 3

Notes:

  • ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
  • ² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
  • ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

DC Voltage, Continuity, Resistance, Diode Test and Capacitance

Function Range Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.09 % + 2
0.15 % + 2
Ω 600 Ω
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
50.00 MΩ
1 Ω
0.1 Ω
0.001 kΩ
0.01 kΩ
0.001 MΩ
0.01 MΩ
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
0.5 % + 2
0.5 % + 1
1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
Capacitance 1000 nF
10.00 μF
100.0 μF
9999 μF¹
1 nF
0.01 μF
0.1 μF
1 μF
1.2 % + 2
10 % typical

Notes:

  • ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

AC and DC Current

Function Range ¹ Resolution Accuracy
mA AC (45 Hz to 1 kHz) 60.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
mA DC 60.00 mA
400.0 mA
0.01 mA
0.1 mA
0.5 % + 3

Notes:

  • ¹ All AC current ranges are specified from 5 % of range to 100 % of range.

Frequency

Range Resolution Accuracy ¹
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 % + 1

Notes:

  • ¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

Input Characteristics

Function Overload Protection Input Impedance (nominal) Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
AC Voltage 1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
DC Voltage 1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz
AC Current Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum

MIN/MAX Recording

Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.

General Specifications

  • Maximum voltage between any terminal and earth ground: 1000 V DC or AC RMS
  • Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
  • Display (LCD) Update rate: 4/sec
  • Volts, amps, ohms: 6000 counts
  • Frequency: 10,000 counts
  • Capacitance: 1,000 counts
  • Battery type: Three AA Alkaline batteries, NEDA 15A IEC LR6
  • Battery life: 300 hours minimum
  • Temperature: Operating: -10 °C to 50 °C, Storage: -40 °C to 60 °C
  • Relative humidity:
      “`html

    • 0 % to 90 % (0 °C to 35 °C)
    • 0 % to 75 % (35 °C to 40 °C)
    • 0 % to 45 % (40 °C to 50 °C)
  • Altitude:
    • Operating: 2,000 m
    • Storage: 12,000 m
  • Temperature coefficient: 0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
  • Wireless frequency: 2.4 GHz ISM Band 20 meter range
  • Size (HxWxL): 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
  • Weight: 340 g (12 oz)
  • Safety standards:
    • US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    • CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    • CE European: IEC/EN 61010-1:2010
  • Electromagnetic compatibility:
    • EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006
    • ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    • FCCID: T68-FWCS IC:6627A-FWCS
  • Ingress Protection (IP) rating: IP54

Fluke CNX t3000 K-Type Wireless Temperature Module

Fluke CNX a3000 AC Wireless Current Clamp Module

5
3 reviews
3
0
0
0
0

3 reviews for Fluke CNX 3000 HVAC System

Clear filters
  1. Michael

    You have a complete site

  2. David

    Thanks for good technical support

  3. yaser

    Value for money
    Durability
    Delivery speed

    I’m completely satisfied with my purchase

Add a review