Fluke CNX 3000 HVAC System
The Fluke CNX 3000 HVAC System provides a comprehensive solution for measuring all common electrical and temperature parameters. This advanced system, part of the Fluke team of wireless troubleshooting tools, enhances efficiency and safety for HVAC professionals by enabling remote monitoring and data collection.
Fluke CNX3000 Key Features
The Fluke CNX 3000 HVAC System consists of the CNX 3000 Wireless Multimeter, the CNX t3000 K-Type Wireless Temperature Module, and the CNX a3000 AC Wireless Current Clamp Module, all designed to meet the demanding needs of modern HVAC measurement tasks.
CNX 3000 Wireless Multimeter
The CNX 3000 Wireless Multimeter offers robust functionality, including:
- True RMS Measurements: Accurate AC and DC voltage measurements up to 1000V and current measurements with 0.01 mA resolution.
- Comprehensive Testing Capabilities: Includes continuity, resistance, diode test, capacitance, and frequency measurements.
- MIN/MAX Recording: Captures and records minimum, maximum, and average values for detailed analysis.
- Safety and Durability: Rated CAT III 1000 V; CAT IV 600 V; IP54, ensuring reliable performance in challenging environments.
CNX t3000 K-Type Wireless Temperature Module
The CNX t3000 K-Type Wireless Temperature Module is designed for precise temperature measurements, featuring:
- Wide Temperature Range: Measures temperatures from -200 °C to 1372 °C with ± 0.5% accuracy.
- Extensive Memory: Capable of recording up to 65,000 readings, providing a thorough record of temperature data.
- Clear Display: Backlit LCD display for easy viewing in various lighting conditions.
- Durability: IP42 rating with the thermocouple attached, ensuring reliable use in diverse environments.
CNX a3000 AC Wireless Current Clamp Module
The CNX a3000 AC Wireless Current Clamp Module is designed for precise current measurements, featuring:
- True RMS AC Current Measurements: Measures up to 400 A with 2% accuracy up to 100Hz and 2-1/2% accuracy up to 500Hz.
- Extensive Memory: Capable of recording up to 65,000 readings, providing a thorough record of current data.
- Clear Display: Backlit LCD display for easy viewing in various lighting conditions.
- Safety and Durability: Rated CAT III 600 V; IP30, ensuring reliable use in diverse environments.
Advanced Wireless System
The CNX wireless system enhances productivity and safety by allowing simultaneous tracking of up to 10 measurement modules. Results can be sent to a PC for detailed analysis, reducing the need for manual data collection.
- Remote Monitoring: Connect the CNX a3000 AC Wireless Current Clamp Module to your test point and view the results up to 20 meters away on the CNX Wireless Multimeter. This feature saves time by minimizing the need to move around to collect multiple measurements.
- Multi-Point Measurements: Use multiple modules to take measurements on three-phase systems simultaneously. This flexibility allows for more comprehensive monitoring and data collection.
- Standalone or System Use: The modules can be used individually as standalone measurement tools or combined with other CNX modules for a complete measurement system.
- Enhanced Safety: View readings from a safe distance, reducing the risk of exposure to hazardous conditions. This is particularly useful for taking readings on moving machinery, where only the measurement module is in harm’s way.
- Data Logging: The CNX remote modules can capture up to 65,000 sets of time-stamped min/max/avg readings, which can be transferred to a PC using the optional adapter. This eliminates the need for manual data recording.
similar product
if you are looking for a similar product visit best fluke multimeter.
Fluke CNX 3000 HVAC System Specifications:
- Range: 400.0 A
- Resolution: 0.1 A
- Accuracy: 400.0 A:2 % ± 5 digits (10 Hz to 100 Hz)
2.5 % ± 5 digits (100 Hz to 500 Hz) - Inrush: Max displayed reading: 999.9A
- Crest factor (50 Hz/60 Hz): 3.0 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 %
- Display : 3-1/2 digits, LCD w/backlight
- Log rate/interval: 1-sec minimum/adjustable by PC
- Battery type: 2 AA, NEDA 15 A, IEC LR6
- Battery life: 400 hours
- Memory: Record up to 65,000 readings
- RF communications: 2.4 GHZ ISM Band
- RF communication range: 20 Meters
- Operating temperature: -10 °C to +50 °C
- Storage temperature: -40 °C to +60 °C
- Operating humidity : 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
- EMC : EN 61326-1:2006
- Safety compliance: EN/IEC 61010-1-30:2010 to 600 V Measurement Category (CAT) III
EN/IEC 61010-2-030:2010
EN/IEC 61010-2-032:2002
Specifications
AC Voltage
Range ¹ | Resolution | Accuracy ² ³ | |
---|---|---|---|
45 Hz to 500 Hz | 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V |
0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
1.0 % + 3 2.0 % + 3 |
500 Hz to 1 kHz | 600.0 mV 6.000 V |
0.1 mV 0.001 V |
2.0 % + 3 |
Notes:
- ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
- ² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
- ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function | Range | Resolution | Accuracy |
---|---|---|---|
mV | 600.0 mV | 0.1 mV | 0.09 % + 2 |
V | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.09 % + 2 0.15 % + 2 |
Ω | 600 Ω 600.0 Ω 6.000 kΩ 60.00 kΩ 600.0 kΩ 50.00 MΩ |
1 Ω 0.1 Ω 0.001 kΩ 0.01 kΩ 0.001 MΩ 0.01 MΩ |
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. 0.5 % + 2 0.5 % + 1 1.5 % + 3 |
Diode test | 2.000 V | 0.001 V | 1 % + 2 |
Capacitance | 1000 nF 10.00 μF 100.0 μF 9999 μF¹ |
1 nF 0.01 μF 0.1 μF 1 μF |
1.2 % + 2 10 % typical |
Notes:
- ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
Function | Range ¹ | Resolution | Accuracy |
---|---|---|---|
mA AC (45 Hz to 1 kHz) | 60.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 |
mA DC | 60.00 mA 400.0 mA |
0.01 mA 0.1 mA |
0.5 % + 3 |
Notes:
- ¹ All AC current ranges are specified from 5 % of range to 100 % of range.
Frequency
Range | Resolution | Accuracy ¹ |
---|---|---|
99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
0.1 % + 1 |
Notes:
- ¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function | Overload Protection | Input Impedance (nominal) | Common Mode Rejection Ratio (1 kΩ unbalance) | Normal Mode Rejection |
---|---|---|---|---|
AC Voltage | 1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz |
DC Voltage | 1100 V RMS | > 10 MΩ < 100 pF | > 60 dB, DC to 60 Hz | |
AC Current | Fused, 44/100 A, 1000 V FAST Fuse | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum |
MIN/MAX Recording
Function | Accuracy |
---|---|
DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. |
AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. |
General Specifications
- Maximum voltage between any terminal and earth ground: 1000 V DC or AC RMS
- Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
- Display (LCD) Update rate: 4/sec
- Volts, amps, ohms: 6000 counts
- Frequency: 10,000 counts
- Capacitance: 1,000 counts
- Battery type: Three AA Alkaline batteries, NEDA 15A IEC LR6
- Battery life: 300 hours minimum
- Temperature: Operating: -10 °C to 50 °C, Storage: -40 °C to 60 °C
- Relative humidity:
- “`html
- 0 % to 90 % (0 °C to 35 °C)
- 0 % to 75 % (35 °C to 40 °C)
- 0 % to 45 % (40 °C to 50 °C)
- Altitude:
- Operating: 2,000 m
- Storage: 12,000 m
- Temperature coefficient: 0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
- Wireless frequency: 2.4 GHz ISM Band 20 meter range
- Size (HxWxL): 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
- Weight: 340 g (12 oz)
- Safety standards:
- US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
- CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
- CE European: IEC/EN 61010-1:2010
- Electromagnetic compatibility:
- EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006
- ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
- FCCID: T68-FWCS IC:6627A-FWCS
- Ingress Protection (IP) rating: IP54
Fluke CNX t3000 K-Type Wireless Temperature Module
Fluke CNX a3000 AC Wireless Current Clamp Module
5
Rated 5 out of 5
3 reviews
Rated 5 out of 5
3
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
3 reviews for Fluke CNX 3000 HVAC System
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Related Products
Kyoritsu KEW 2500 DC Milliamp Clamp Meter
Rated 5.00 out of 5
(1)
In stock
Michael –
You have a complete site
David –
Thanks for good technical support
yaser –