Fluke CNX i3000 iFlex AC Current Measurement Kit
Short Description:
The Fluke CNX i3000 iFlex AC Current Measurement Kit is part of the Fluke team of wireless troubleshooting tools.
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
15
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke CNX i3000 iFlex AC Current Measurement Kit
The Fluke CNX i3000 iFlex® AC Current Measurement Kit provides a comprehensive solution for measuring all common electrical parameters. This advanced kit, part of the Fluke team of wireless troubleshooting tools, enhances efficiency and safety for professionals by enabling remote monitoring and data collection.
Key Features
The Fluke CNX i3000 iFlex® AC Current Measurement Kit consists of the CNX 3000 Wireless Multimeter and the CNX i3000 iFlex® AC Wireless Current Module, both designed to meet the demanding needs of modern electrical measurement tasks.
CNX 3000 Wireless Multimeter
The CNX 3000 Wireless Multimeter offers robust functionality, including:
- True RMS Measurements: Accurate AC and DC voltage measurements up to 1000V and current measurements with 0.01 mA resolution.
- Comprehensive Testing Capabilities: Includes continuity, resistance, diode test, capacitance, and frequency measurements.
- MIN/MAX Recording: Captures and records minimum, maximum, and average values for detailed analysis.
- Safety and Durability: Rated CAT III 1000 V; CAT IV 600 V; IP54, ensuring reliable performance in challenging environments.
CNX i3000 iFlex® AC Wireless Current Module
The CNX i3000 iFlex® AC Wireless Current Module is designed for precise current measurements, featuring:
- True RMS AC Current Measurements: Measures up to 2500 A with 3% accuracy.
- Extensive Memory: Capable of recording up to 65,000 readings, providing a thorough record of current data.
- Flexible Probe: The iFlex® Current Probe allows you to get into tight, awkward spaces for more accurate measurements.
- Clear Display: Backlit LCD display for easy viewing in various lighting conditions.
- Safety and Durability: Rated CAT III 1000 V; CAT IV 600 V; IP42, ensuring reliable use in diverse environments.
Advanced Wireless System
The CNX wireless system enhances productivity and safety by allowing simultaneous tracking of up to 10 measurement modules. Results can be sent to a PC for detailed analysis, reducing the need for manual data collection.
- Remote Monitoring: Connect the CNX i3000 iFlex® AC Wireless Current Module to your test point and view the results up to 20 meters away on the CNX Wireless Multimeter. This feature saves time by minimizing the need to move around to collect multiple measurements.
- Multi-Point Measurements: Use multiple modules to take measurements on three-phase systems simultaneously. This flexibility allows for more comprehensive monitoring and data collection.
- Standalone or System Use: The modules can be used individually as standalone measurement tools or combined with other CNX modules for a complete measurement system.
- Enhanced Safety: View readings from a safe distance, reducing the risk of exposure to hazardous conditions. This is particularly useful for taking readings on moving machinery, where only the measurement module is in harm’s way.
- Data Logging: The CNX i3000 current module can capture up to 65,000 sets of time-stamped min/max/avg readings, which can be transferred to a PC using the optional adapter. This eliminates the need for manual data recording.
Fluke CNX i3000 iFlex AC Current Measurement Kit Specifications:
- Range: 2500 A AC
- Resolution: 0.1 A to 999.9, 1A from 1000 to 2500
- Accuracy : 3 % ± 5 digits
- Crest factor (50 Hz/60 Hz): 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
- Display : 3-1/2 digits, LCD w/backlight
- Log rate/interval: 1-sec minimum/adjustable by PC or front panel
- Battery type: 2 AA, NEDA 15 A, IEC LR6
- Battery life: 400 hours
- Memory: Record up to 65,000 readings
- RF communications: 2.4 GHZ ISM Band
- RF communication range: 20 Meters
- Operating temperature: -10 °C to +50 °C
- Storage temperature: -40 °C to +60 °C
- Operating humidity: 90 % at 35 °C
75 % at 40 °C
45 % at 50 °C
Similar Products
If you’re looking for a fluke digital multimeter visit the link
Specifications
Range ¹ | Resolution | Accuracy ² ³ | |
---|---|---|---|
45 Hz to 500 Hz | |||
500 Hz to 1 kHz | |||
600.0 mV | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 |
6.000 V | 0.001 V | ||
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V |
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function | Range | Resolution | Accuracy |
---|---|---|---|
mV | 600.0 mV | 0.1 mV | 0.09 % + 2 |
V | 6.000 V | 0.001 V | 0.09 % + 2 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | 0.15 % + 2 | |
Ω | 600 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. |
600.0 Ω | 0.1 Ω | 0.5 % + 2 | |
6.000 kΩ | 0.001 kΩ | 0.5 % + 1 | |
60.00 kΩ | 0.01 kΩ | ||
60.00 kΩ | 0.1 kΩ | ||
600.0 kΩ | 0.001 MΩ | ||
50.00 MΩ | 0.01 MΩ | 1.5 % + 3 | |
Diode test | 2.000 V | 0.001 V | 1 % + 2 |
μF | 1000 nF | 1 nF | 1.2 % + 2 |
10.00 μF | 0.01 μF | ||
100.0 μF | 0.1 μF | ||
9999 μF¹ | 1 μF | 10 % typical |
¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
Function | Range ¹ | Resolution | Accuracy |
---|---|---|---|
mA AC (45 Hz to 1 kHz) | 60.00 mA | 0.01 mA | 1.5 % + 3 |
400.0 mA ³ | 0.1 mA | ||
mA DC ² | 60.00 mA | 0.01 mA | 0.5 % + 3 |
400.0 mA | 0.1 mA |
¹ All AC current ranges are specified from 5 % of range to 100 % of range.
² Input burden voltage (typical): 400 mA input 2 mV/mA.
³ 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range | Resolution | Accuracy ¹ |
---|---|---|
99.99 Hz | 0.01 Hz | 0.1 % + 1 |
999.9 Hz | 0.1 Hz | |
9.999 kHz | 0.001 kHz | |
99.99 kHz | 0.01 kHz |
Input Characteristics
Function | Overload Protection | Input Impedance (nominal) | Common Mode Rejection Ratio (1 kΩ unbalance) | Normal Mode Rejection |
---|---|---|---|---|
AC Voltage | 1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz |
DC Voltage | 1100 V RMS | > 10 MΩ < 100 pF | > 60 dB, DC to 60 Hz | |
AC Current | Fused, 44/100 A, 1000 V FAST Fuse | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum |
MIN/MAX Recording
Function | Accuracy |
---|---|
DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. |
AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. |
Fluke CNX i3000 iFlex® AC Wireless Current Module
Specifications | |
---|---|
Range | 2500 A AC |
Resolution | 0.1 A to 999.9, 1A from 1000 to 2500 |
Accuracy | 3 % ± 5 digits |
Crest factor (50 Hz/60 Hz) | 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 |
Display | 3-1/2 digits, LCD w/backlight |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel |
Battery type | 2 AA, NEDA 15 A, IEC LR6 |
Battery life | 400 hours |
Memory | Record up to 65,000 readings |
RF communications | 2.4 GHZ ISM Band |
RF communication range | 20 Meters |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -40 °C to +60 °C |
Operating humidity | 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C |
EMC | EN 61326-1:2006 |
Safety compliance | EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III, 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 610101-2-031:2002 EN/IEC 61010-2-032:2002 |
Pollution degree | 2 |
Temperature coefficient | Add 0.1 X (specified accuracy) / °C per °C (<18 °C or >28 °C) |
Safety rating | CAT IV 600 V, CAT III 1000 V |
Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS |
Ingress Protection (IP) rating | IP42 |
Size (HxWxD) | 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) |
Weight | 0.22 kg (8 oz) |
Jaw opening | 25.4 cm (10 in) coil |
5
Rated 5 out of 5
2 reviews
Rated 5 out of 5
2
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
2 reviews for Fluke CNX i3000 iFlex AC Current Measurement Kit
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Related Products
Fluke 28 ii Ex Intrinsically Safe Digital Multimeter
Rated 5.00 out of 5
(3)
In stock
Fluke 279 FC True-rms Thermal Multimeter
Rated 5.00 out of 5
(1)
In stock
Fluke 289 TRMS Logging Multimeter with TrendCapture
Rated 5.00 out of 5
(2)
In stock
Fluke 233 Remote Display Digital Multimeter
Rated 5.00 out of 5
(1)
In stock
FLUKE 3000 Series Wireless Digital Multimeters with Fluke Connect
Rated 5.00 out of 5
(1)
In stock
Call for Price
Barbara –
Great device
mark –