Fluke CNX t3000 Temperature Measurement Kit

The Fluke CNX t3000 Temperature Measurement Kit provides a comprehensive solution for measuring all common electrical and temperature parameters. This advanced kit, part of the Fluke wireless troubleshooting tools, enhances efficiency and safety for professionals by allowing remote monitoring and data collection.

Fluke CNX-t3000 Key Features

The Fluke CNX t3000 Temperature Measurement Kit consists of the CNX 3000 Wireless Multimeter and the CNX t3000 K-Type Wireless Temperature Module, both packed with advanced features to meet the demands of modern electrical and temperature measurement tasks.

CNX 3000 Wireless Multimeter

The CNX 3000 Wireless Multimeter offers robust functionality, including:

  • True RMS Measurements: Accurate AC and DC voltage measurements up to 1000V and current measurements with 0.01 mA resolution.
  • Comprehensive Testing Capabilities: Continuity, resistance, diode test, capacitance, and frequency measurements.
  • MIN/MAX Recording: Captures and records minimum, maximum, and average values for detailed analysis.
  • Safety and Durability: Rated CAT III 1000 V; CAT IV 600 V; IP54, ensuring reliable performance in challenging environments.

CNX t3000 K-Type Wireless Temperature Module

The CNX t3000 K-Type Wireless Temperature Module is designed for precise temperature measurements, featuring:

  • Wide Temperature Range: Measures temperatures from -200 °C to 1372 °C with ± 0.5% accuracy.
  • Extensive Memory: Capable of recording up to 65,000 readings, providing a thorough record of temperature data.
  • Clear Display: Backlit LCD display for easy viewing in various lighting conditions.
  • Durability: IP42 rating with the thermocouple attached, ensuring reliable use in diverse environments.

Advanced Wireless System

The CNX wireless system enhances productivity and safety by allowing simultaneous tracking of up to 10 measurement modules. Results can be sent to a PC for detailed analysis, reducing the need for manual data collection.

  • Remote Monitoring: Connect the CNX t3000 Wireless Temperature Module to your test point and view the results up to 20 meters away on the CNX Wireless Multimeter. This feature saves time by minimizing the need to move around to collect multiple measurements.
  • Multi-Point Measurements: Use multiple modules to take measurements at several test points simultaneously. This flexibility allows for more comprehensive monitoring and data collection.
  • Standalone or System Use: The modules can be used individually as standalone measurement tools or combined with other CNX modules for a complete measurement system.
  • Enhanced Safety: View readings from a safe distance, reducing the risk of exposure to hazardous conditions. This is particularly useful for taking readings on moving machinery, where only the measurement module is in harm’s way.
  • Data Logging: The CNX t3000 temperature module can capture up to 65,000 sets of time-stamped min/max/avg readings, which can be transferred to a PC using the optional adapter. This eliminates the need for manual data recording.

Fluke CNXt3000 Temperature Measurement Kit Specifications:

  • Range : -200 °C to 1372 °C
  • Resolution : 0.1 °C
  • Accuracy : ±[0.5 % + 0.3 °C] counts
  • Input terminals : K-Type mini
  • LCD w/backlight : 3 digits
  • Log rate/interval : 1 sec minimum/adjustable by PC
  • Battery type : 2 AA, NEDA 15 A, IEC LR6
  • Battery life : 400 hours
  • Memory : Record up to 65,000 readings
  • RF communications : 2.4 GHZ ISM Band
  • RF communication range : 20 Meters
  • Operating temperature : -10 °C to +50 °C
  • Storage temperature : -40 °C to +60 °C
  • Temperature scale : ITS-90
Data Sheet

Data Sheet

Data Sheet

Specifications

Specifications

AC Voltage
Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz 1.0 % + 3
500 Hz to 1 kHz 2.0 % + 3
600.0 mV 0.1 mV
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V

Notes:

  • ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
  • ² Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
  • ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function Range Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω 600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5 % + 1
60.00 kΩ 0.01 kΩ
600.0 kΩ 0.1 kΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
μF 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF¹ 1 μF 10 % typical

Notes:

  • ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
Function Range ¹ Resolution Accuracy
mA AC (45 Hz to 1 kHz) 60.00 mA 0.01 mA 1.5 % + 3
400.0 mA ³ 0.1 mA
mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA 0.1 mA

Notes:

  • ¹ All AC current ranges are specified from 5 % of range to 100 % of range.
  • ² Input burden voltage (typical): 400 mA input 2 mV/mA.
  • ³ 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range Resolution Accuracy ¹
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
“`html
9.999 kHz
0.001 kHz
99.99 kHz 0.01 kHz

Notes:

  • ¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function Overload Protection Input Impedance (nominal) Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Full Scale Typical Short Circuit Current
< 2.7 V DC To 6 MΩ: < 0.7 V DC, 50 MΩ: < 0.9 V DC < 350 mA
< 2.7 V DC To 6 MΩ: 2.000 V DC < 1.1 mA
Overload Protection
Function Overload Protection Overload
mA Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.

General Specifications

Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Relative humidity 0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Temperature coefficient 0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
Wireless frequency 2.4 GHz ISM Band 20 meter range
Size (HxWxL) 4.75 cm x 9.3 cm x 20.7 cm
(1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP54

Notes:

  • Accuracy is specified as ± ([% of reading] + [number of least significant digits]).
  • All ranges are autoranging.
  • Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

Fluke CNX t3000 Wireless K-Type Temperature Module

Specifications
Range Resolution Accuracy
-200 °C to 1372 °C 0.1 °C ±[0.5 % + 0.3 °C] counts

“`html

Additional Information
Input terminals LCD w/backlight Log rate/interval Battery type Battery life Memory RF communications RF communication range Operating temperature Storage temperature Temperature scale Operating humidity EMC Safety compliance Pollution degree Temperature coefficient Certifications Ingress Protection (IP) rating Size (HxWxD) Weight
K-Type mini 3 digits 1 sec minimum/adjustable by PC 2 AA, NEDA 15 A, IEC LR6 400 hours Record up to 65,000 readings 2.4 GHZ ISM Band 20 Meters -10 °C to +50 °C -40 °C to +60 °C ITS-90 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C EN 61326-1:2006 CAT I per IEC/EN 61010-1:2010, EN/IEC 61010-2-030:2010 2 0.01 % of reading +0.03 °C per °C CSA, FCC T68-FWCS IC:6627A-FWCS IP42 with thermocouple attached 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) 0.22 kg (8 oz)
Reviews (3)
5
3 reviews
3
0
0
0
0

3 reviews for Fluke CNX t3000 Temperature Measurement Kit

Clear filters
  1. Jarvis

    Professional Temperature

  2. Susan

    Has a good measurement range

  3. mark

    Value for money
    Durability
    Delivery speed

    It’s very easy and accurate to use.

Add a review