Fluke CNX v3000 AC Voltage Kit

The Fluke CNX v3000 AC Voltage Kit provides a comprehensive solution for measuring all common electrical parameters. This advanced kit, part of the Fluke team of wireless test tools, enhances efficiency and safety for professionals by enabling remote monitoring and data collection.

Fluke CNX v3000 Kit Key Features

The Fluke CNX v3000 AC Voltage Kit consists of the CNX 3000 Wireless Multimeter and the CNX v3000 AC Wireless Voltage Module, both designed to meet the demanding needs of modern electrical measurement tasks.

CNX 3000 Wireless Multimeter

The CNX 3000 Wireless Multimeter offers robust functionality, including:

  • True RMS Measurements: Accurate AC and DC voltage measurements up to 1000V and current measurements with 0.01 mA resolution.
  • Comprehensive Testing Capabilities: Includes continuity, resistance, diode test, capacitance, and frequency measurements.
  • MIN/MAX Recording: Captures and records minimum, maximum, and average values for detailed analysis.
  • Safety and Durability: Rated CAT III 1000 V; CAT IV 600 V; IP54, ensuring reliable performance in challenging environments.
  • CNX v3000 AC Wireless Voltage Module

The CNX v3000 AC Wireless Voltage Module is designed for precise voltage measurements, featuring:

  • True RMS AC Voltage Measurements: Measures up to 1000V with ±1% accuracy up to 500 Hz and ±2% accuracy up to 1 kHz.
  • Extensive Memory: Capable of recording up to 65,000 readings, providing a thorough record of voltage data.
  • Clear Display: Backlit LCD display for easy viewing in various lighting conditions.
  • Safety and Durability: Rated CAT III 1000 V; CAT IV 600 V; IP42, ensuring reliable use in diverse environments.

Advanced Wireless System

The CNX wireless system enhances productivity and safety by allowing simultaneous tracking of up to 10 measurement modules. Results can be sent to a PC for detailed analysis, reducing the need for manual data collection.

  • Remote Monitoring: Connect the CNX v3000 AC Wireless Voltage Module to your test point and view the results up to 20 meters away on the CNX Wireless Multimeter. This feature saves time by minimizing the need to move around to collect multiple measurements.
  • Multi-Point Measurements: Use multiple modules to take measurements on three-phase systems simultaneously. This flexibility allows for more comprehensive monitoring and data collection.
  • Standalone or System Use: The modules can be used individually as standalone measurement tools or combined with other CNX modules for a complete measurement system.
  • Enhanced Safety: View readings from a safe distance, reducing the risk of exposure to hazardous conditions. This is particularly useful for taking readings on moving machinery, where only the measurement module is in harm’s way.
  • Data Logging: The CNX v3000 voltage module can capture up to 65,000 sets of time-stamped min/max/avg readings, which can be transferred to a PC using the optional adapter. This eliminates the need for manual data recording.

Fluke CNX v3000 AC Voltage Kit Specifications:

  • Display : 3-1/2 digits, LCD w/backlight
  • Battery type : 2 AA, NEDA 15 A, IEC LR6
  • Battery life : 400 hours
  • Memory : Record up to 65,000 readings
  • Unbound listen interval : 5 seconds
  • RF communications : 2.4 GHZ ISM Band
  • RF communication range : 20 Meters
  • Operating temperature : -10 °C to +50 °C
  • Storage temperature : -40 °C to +60 °C
  • Operating humidity : 90 % at 35 °C
    75 % at 40 °C
    45 % at 50 °C
  • EMC : EN 61326-1:2006
  • Safety compliance : EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
    600 V Measurement Category (CAT) IV
    EN/IEC 61010-2-030:2010
    EN/IEC 61010-031:2002+A1:2008
  • Pollution degree : v
  • Temperature coefficient : Add 0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
  • Certifications : CSA, FCC T68-FWCS IC:6627A-FWCSSafety rating : CAT IV 600 V, CAT III 1000 V
  • Ingress Protection (IP) rating : IP42
  • Size (HxWxD) : 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
  • Weight : .22 kg (8 oz)

Datasheet

Datasheet

Mme-Pdfs-Image

Specifications

Specifications

Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz
500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V

¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.

² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.

³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

DC Voltage, Continuity, Resistance, Diode Test and Capacitance

Function Range Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5 % + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
μF 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF¹ 1 μF 10 % typical

¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

AC and DC Current

Function Range ¹ Resolution Accuracy
mA AC (45 Hz to 1 kHz) 60.00 mA 0.01 mA 1.5 % + 3
400.0 mA ³ 0.1 mA
mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA 0.1 mA

¹ All AC current ranges are specified from 5 % of range to 100 % of range.

² Input burden voltage (typical): 400 mA input 2 mV/mA.

³ 400.0 mA accuracy specified up to 600 mA overload.

Frequency

Range Resolution Accuracy ¹
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz

¹ Frequency is specified up to 99.99 kHz in volts“`html
and up to 10 kHz in amps.

Input Characteristics

Function Overload Protection Input Impedance (nominal) Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale Typical short circuit current
1100 V RMS < 2.7 V DC To 6 MΩ: < 0.7 V DC, 50 MΩ: < 0.9 V DC < 350 mA
1100 V RMS < 2.7 V DC To 6 MΩ: 2.000 V DC < 1.1 mA

Function Overload Protection

Function Overload Protection Overload
mA Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum

MIN/MAX Recording

Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.

General Specifications

Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec, Volts, amps, ohms: 6000 counts, Frequency: 10,000 counts, Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
Temperature Operating: -10 °C to 50 °C, Storage: -40 °C to 60 °C
Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m, Storage: 12,000 m
Temperature coefficient 0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
Wireless frequency 2.4 GHz ISM Band 20 meter range
Size (HxWxL) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition, CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition, CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility EN 61326-1:2006, EN 61326-2-2:2006, ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP54

• Accuracy is specified as ± ([% of reading] + [number of least significant digits]).

• All ranges are autoranging.

• Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

Fluke CNX v3000 AC Wireless Voltage Module

Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

AC Voltage

Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz
500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V