The FEV150 offers a comprehensive solution for safety and performance testing of AC EV charging stations equipped with Type 1 (J1772) or Tesla connectors. Ensuring reliable operation, the FEV150 represents Fluke’s latest advancement in EV charging test solutions, enabling technicians to conduct and document various tests safely, quickly, and efficiently, all without the need for multiple tools.
This all-in-one solution features TruTest™ EV Charging software, which seamlessly integrates with the FEV150 through a Bluetooth connection. TruTest provides predefined test plans, pass/fail indicators, and pre-test voltage safety information. By utilizing the FEV150 and TruTest automation, you can complete tasks more safely, efficiently, and with a reduced risk of errors.
Fluke FEV150 Key Features
- Test the safety and functionality of AC electrical vehicle charging stations with the all-in-one solution
- GFCI Trip Test
- Pass/fail test results
- Auto control pilot (CP) with waveform analysis
- Compatible with TruTest™️ Data Management Software
specifications
Test/function | Display Range | Measurement Range | Operational Error | Nominal values |
PE pre-test | ||||
Touch voltage, safe range | ≤50 V ac/dc | -50% | — | |
Touch voltage, dangerous range | >50 V ac/dc | 0% | — | |
Visual inspection checklist | · | — | — | |
GFCI Trip | ||||
Quick trip | 30 mA, trip time limit: 0.56 s | Test current: 0% to 10% | 100 V ac to 253 Vac, 45 Hz to 66 Hz | |
Trobouble shooting 6 mA GFCI | 3.5 mA, no trip | Test current: -10% to 0% | ||
10 mA, trip time limit: 2.69 s | Test current: 0% to 10% | |||
Trobouble shooting 20 mA GFCI | 6 mA, no trip | Test current: -10% to 0% | ||
30 mA, trip time limit: 0.56 s | Test current: 0% to 10% | |||
Nominal voltage | ||||
L1-L2/N | 0 V ac to 280 Vac | 0 Vac to 253 Vac | ±(3% + 3 digits) | 40 Hz to 70 Hz, crest factor 2 |
Frequency | 40.00 Hz to 70.00 Hz | ±0.20 Hz | — | |
CP signal analysis | ||||
Voltage | -15.000 V to | -15.000 V to | ±0.5 % | RIN: 1 MΩ |
15.000 V | -2.000 V, | 0.9000 kHz to | ||
2.000 V to | 1.1000 kHz; | |||
15.000 V | UCP+ >2.000 V, | |||
PWM duty cycle | 2.0 % to 98.0 % | 3.0 % to 97.0 % | ±5 digits | UCP- <-2.000 V |
Current indication | 0.0 A to 80.0 A | — | Based on duty cycle[2] | |
Frequency | 0.9000 kHz to 1.1000 kHz | 0.10% | ||
CP state indication | A, B, C, D | — | Based on voltage[1] | |
x1, x2 | — | Based on frequency[1] | ||
CP state simulation | A | — | — | >900 kΩ ±0.2 % |
B | — | Upper level: 4610 Ω | ||
±0.2 %[1] | ||||
Nominal level: 2740 Ω | ||||
±0.2 %[1] | ||||
Lower level: 1870 Ω | ||||
±0.2 %[1] | ||||
C | — | Upper level: 1254.2 Ω | ||
±0.2 %[1] | ||||
Nominal level: 881.7 Ω | ||||
±0.2 %[1] | ||||
Lower level: 611.7 Ω | ||||
±0.2 %[1] | ||||
D | — | Upper level: 408.3 Ω | ||
±0.2 %[1] | ||||
Nominal level: 245.8 Ω | ||||
±0.2 %[1] | ||||
Lower level: 130.2 Ω | ||||
±0.2 %[1] | ||||
Fault simulation | PE error (earth | Pass/Fail | — | — |
fault/PE open) | ||||
CP error E | Pass/Fail | 0 Ω +2 Ω | — | |
Diode short | Pass/Fail | — | — | |
Error D | Pass/Fail | — | — | |
PP resistor measurement | 50.0 Ω to 499.9 Ω, | ±1.0 % | — | |
Type 1 with cable (S3, R6, R7) | 500 Ω to 5000 Ω | |||
CP resistor measurement (R1) | 800 Ω to 1200 Ω | ±1.0 % | — | |
[1] According to IEC 61851-1. | ||||
[2] According to table A.8 of IEC 61851-1. | ||||
General specification | ||||
Input elctrical ratings | 250 V max | |||
50/60 Hz, max 1 A | ||||
EV connector | SAE J1772 socket (type 1, 5P single-phase) | |||
Internal power consumption | 3W max | |||
Size (H x W x D) | ∼(263 mm x 123 mm x 63 mm) | |||
∼(10.35 in x 4.84 in x 2.48 in) without the TY1 | ||||
Weight | ∼0.9 kg, without the TY1 connector | |||
∼1.4 kgn with the TY1 connector | ||||
Battery | 4 x AA/IEC LR6 alkaline or IEC HR6 NiMH | |||
Temperature | ||||
Operating | -10 °C to 40 °C (14 °F to 104 °F) | |||
Storage | -20 °C to 50 °C (-4 °F to 122 °F) | |||
Relative humidity | ||||
Operating | 10 % to 85 %, 0 °C to 40 °C | |||
(32 °F to 104 °F), non-condensing | ||||
Storage | up to 95 % | |||
Altitude | 3000 m | |||
Ingress protection | IP40 | |||
Wireless radio, Bluetooth 5.0 | ||||
Frequency range | 2400 MHz to 2483.5 MHz | |||
Output power | <100 mW |