The Fluke FLK-IRR1-SOL Solar Irradiance Meter is a powerful tool that simplifies photovoltaic system installation, testing, and maintenance. Its comprehensive set of features, including solar irradiance measurement, temperature sensing, and orientation detection, make it an indispensable asset for solar installers and technicians.
- Measuring Range: 100 to 1400 W/m²
- Resolution: 1 W/m²
- Measuring Accuracy: ± (5 % + 5 Digit)
Call for Best Price 00971(04) 447 6031 00971(04) 344 9868
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Buy Fluke FLK-IRR1-SOL
The Fluke FLK-IRR1-SOL Solar Irradiance Meter is a versatile tool designed specifically for solar installers and technicians. It simplifies the process of installing, commissioning, and troubleshooting photovoltaic systems by providing critical measurements in a single, easy-to-use device. This meter is ideal for professionals working on rooftop systems or large field installations, offering a comprehensive set of features to enhance efficiency and accuracy.
Key Features and Benefits
The Fluke FLK-IRR1-SOL is equipped with several key features that make it an indispensable tool for solar professionals:
- Solar Irradiance Measurement: Measures solar irradiance up to 1400 W/m² with a resolution of 1 W/m² and an accuracy of ±(5% + 5 digits).
- Temperature Measurement: The Fluke FLK-IRR1-SOL offers two options for temperature measurement: a built-in sensor and an external suction-mount temperature probe, which allow for both ambient and panel temperature readings.
- Integrated Compass and Inclination Sensor: These features enable users to measure and document roof or site orientation and PV panel tilt, which are crucial for optimizing solar array performance.
- High-Contrast LCD Screen: This screen is easily readable in direct sunlight, ensuring that measurements can be taken efficiently even in challenging outdoor conditions.
- Portable Design: Includes a protective carrying case with a shoulder strap, making it easy to transport and store.
Design and Functionality
The Fluke FLK-IRR1-SOL is designed with a rugged, compact body and a user-friendly interface. It is powered by four AA alkaline batteries, offering a typical battery life of 50 hours or over 9,000 readings. The meter operates within a temperature range of -20°C to +50°C and can store data in environments from -30°C to +60°C. Its IP40 protection ensures durability against minor environmental factors.
Applications
The Fluke FLK-IRR1-SOL is essential for various applications in the solar industry, including:
- Photovoltaic System Design and Surveying: Helps determine the solar resource and expected production at a site by measuring irradiance and accounting for shading.
- Installation and Commissioning: Ensures that solar panels are installed correctly by measuring orientation, tilt, and temperature.
- Maintenance and Troubleshooting: Facilitates ongoing analysis and diagnosis of solar systems to ensure optimal performance.
Fluke FLK-IRR1-SOL Specifications
The Fluke FLK-IRR1-SOL has a measuring range of 100 to 1400 W/m² with a resolution of 1 W/m².
Irradiance | |
Measuring Range | 100 to 1400 W/m² |
Resolution | 1 W/m² |
Measuring Accuracy | ± (5 % + 5 Digit) |
Note: Irradiance measurement accuracy is specified for an angle of incidence ≤35 degrees from the sun at AM1.5 (ASTM G-173) spectrum. | |
Temperature Measurement | |
Measuring range (°C) | -30 °C to 100 °C (-22 °F to 212 °F) |
Resolution | 0.1 °C (0.2 °F) / 1 °F @>100 °F |
Measuring Accuracy | “±5 °C (±9 °F)@ -10 °C to 75 °C (14 °F to 167 °F), |
±8 °C (±14.5 °F)@ -30 °C to -10 °C (-22 °F to 14 °F), and | |
75 °C to 100 °C (167 °F to 212 °F)” | |
Note: Temperature measurement response time: ~30 sec. | |
Inclination Angle | |
Measuring Range | -90° to +90° |
Resolution | 0.1° |
Measuring Accuracy (typical) | ± 1.5°@ -50° to +50° |
±2.5° @ -85° to -50° and +50° to +85° | |
±3.5° @ -90° to -85° and +85° to +90° | |
Compass | |
Measuring Range | 0° to 360° |
Resolution | 1° |
Measuring Accuracy | ±7° |
Note: | |
a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown “—“. | |
b) Result is referred to magnetic north. | |
Temperature | |
Operating Temperature IRR1-SOL | -20 °C to 50 °C (humidity <80%), noncondensing |
Operating Temperature 80PR-IRR | -30 °C to +100 °C |
Storage Temperature | -30 °C to 60 °C (humidity <80%) |
Altitude | 0 m to max. 2000 m |
Electromagnetic Compatibility (EMC) | |
International | IEC 61326-1: Portable Electromagnetic Environment |
CISPR 11: Group 1, Class A | |
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. | |
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. | |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) |
Class A Equipment (Industrial Broadcasting & Communication Equipment) | |
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Protection | |
IP Protection | IP40 |
Power Supply & Battery Life | |
Batteries | 4 AA Alkaline Batteries |
Battery Life (typical) | 50 hours (≤9000 readings) |
Auto Power Off | 30 minutes |
Dimensions | |
L x W x H | 150 x 80 x 35 mm (5.90 x 3.14 x 1.37 in) |
Weight | 231 g (0.5 lb) |
Buy the Fluke FLK-IRR1-SOL Solar Irradiance Meter, an essential tool that simplifies the installation, testing, and maintenance of photovoltaic systems. With a comprehensive set of features, including solar irradiance measurement, temperature sensing, and orientation detection, this meter is an invaluable asset for solar installers and technicians.
Irradiance |
Measuring Range: 100 to 1400 W/m² |
---|---|
Temperature Measurement |
Measuring range (°C): -30 °C to 100 °C (-22 °F to 212 °F) |
Inclination Angle |
Measuring Range: -90° to +90° |
Compass |
Measuring Range: 0° to 360° |
Protection |
IP40 |
Power Supply & Battery Life |
Batteries: 4 AA Alkaline Batteries |
Dimensions |
150 x 80 x 35 mm (5.90 x 3.14 x 1.37 in) |
Weight |
231 g (0.5 lb) |
Specifications
Irradiance | |
Measuring Range | 100 to 1400 W/m² |
Resolution | 1 W/m² |
Measuring Accuracy | ± (5 % + 5 Digit) |
Note: Irradiance measurement accuracy is specified for an angle of incidence ≤35 degrees from the sun at AM1.5 (ASTM G-173) spectrum. | |
Temperature Measurement | |
Measuring range (°C) | -30 °C to 100 °C (-22 °F to 212 °F) |
Resolution | 0.1 °C (0.2 °F) / 1 °F @>100 °F |
Measuring Accuracy | “±5 °C (±9 °F)@ -10 °C to 75 °C (14 °F to 167 °F), |
±8 °C (±14.5 °F)@ -30 °C to -10 °C (-22 °F to 14 °F), and | |
75 °C to 100 °C (167 °F to 212 °F)” | |
Note: Temperature measurement response time: ~30 sec. | |
Inclination Angle | |
Measuring Range | -90° to +90° |
Resolution | 0.1° |
Measuring Accuracy (typical) | ± 1.5°@ -50° to +50° |
±2.5° @ -85° to -50° and +50° to +85° | |
±3.5° @ -90° to -85° and +85° to +90° | |
Compass | |
Measuring Range | 0° to 360° |
Resolution | 1° |
Measuring Accuracy | ±7° |
Note: | |
a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown “—“. | |
b) Result is referred to magnetic north. | |
Temperature | |
Operating Temperature IRR1-SOL | -20 °C to 50 °C (humidity <80%), noncondensing |
Operating Temperature 80PR-IRR | -30 °C to +100 °C |
Storage Temperature | -30 °C to 60 °C (humidity <80%) |
Altitude | 0 m to max. 2000 m |
Electromagnetic Compatibility (EMC) | |
International | IEC 61326-1: Portable Electromagnetic Environment |
CISPR 11: Group 1, Class A | |
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. | |
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. | |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) |
Class A Equipment (Industrial Broadcasting & Communication Equipment) | |
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Protection | |
IP Protection | IP40 |
Power Supply & Battery Life | |
Batteries | 4 AA Alkaline Batteries |
Battery Life (typical) | 50 hours (≤9000 readings) |
Auto Power Off | 30 minutes |
Dimensions | |
L x W x H | 150 x 80 x 35 mm (5.90 x 3.14 x 1.37 in) |
Weight | 231 g (0.5 lb) |