Fluke PVA-1500T2 PV Analyzer, I-V Curve Tracer
Short Description:
Buy the Fluke PVA-1500T2 at unbeatable prices in Dubai, UAE! Explore top-quality testing solutions for your needs today.
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
15
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Introduction of Fluke PVA-1500T2
The Fluke PVA-1500T2 PV Analyzer is an advanced I-V curve tracer designed for precise performance measurement and analysis of photovoltaic (PV) systems. This cutting-edge device enables detailed assessments of solar modules and arrays, making it an indispensable tool for professionals involved in the installation, maintenance, and optimization of solar energy systems.
For commissioning, operations, maintenance, and troubleshooting of PV arrays, I-V curve testing provides the most comprehensive assessment of solar module performance. Rapid analysis of curve datasets helps identify anomalies, and the stored data serves as a benchmark for future performance evaluations.
Fluke PVA-1500 Series Key Features
- Measures and displays I-V curves up to 1500V and 30A, including on high efficiency modules (PVA-1500HE2)
- Advanced built-in PV model provides immediate PV performance checking
- Sweep-to-sweep delay of 9 seconds to measure 3.5MW in <1hr
- Wireless interfaces for faster setup, safer work environment, and freedom of movement during PV troubleshooting
- Automates data management, analysis, and reporting
Specifications
Fluke PVA-1500 Specifications
PVA-1500 Specifications | ||
PVA-1500T2 | PVA-1500HE2 | |
Voltage Range (Voc) | 20 to 1500V DC | |
Maximum Current Range (Isc) | ||
Module Efficiency <19% | 0 to 30A DC | |
Module Efficiency ≥19% | 0 to 10A DC | 0 to 30A DC |
Voltage Accuracy (0 °C to 45 °C) | ±(0.5% ±0.25V) | |
Current Accuracy (0 °C to 45 °C) | ±(0.5% ±0.04A) | |
Power Accuracy (0 °C to 45 °C) | ±(1.7 % + 1.0 W) (current ≥3 A, module efficiency <19 %) | |
Voltage Resolution | 25 mV | |
Current Resolution | 2 mA | |
Measurement Throughput | ||
Sweep-to-sweep delay (@VOC ≤ 1350V) | <9 seconds | |
Max number of I-V sweeps per hour (@VOC ≤ 1350V) | 400 sweeps/hr | |
Max megawatts measured per hour | 3.5 MW/hr | |
Thermal Capacity | ||
# sweeps at 18 s sweep-to-sweep delay | unlimited (25 °C, 77 °F ambient) 550 (45 °C, 113 °F ambient) |
|
# sweeps at 9s sweep-to-sweep delay | unlimited (25 °C, 77 °F ambient) 330 (45 °C, 113 °F ambient) |
|
I-V Trace Points | 100 or 500 (selectable) | |
I-V Sweep Duration | 0.05 to 2 seconds (typically 0.2 seconds for PV strings) | |
Operating Temperature Range | 0 °C to 45 °C, 32 °F to 113 °F | |
Storage Temperature Range | -20 °C to 65 °C, -4 °F to 149 °F | |
Operating Humidity | <90 % RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used. | |
Altitude | 2000 m max | |
Battery Charging Time | 6 hr | |
Battery Run Time | Approx. 8 hr | Approx. 7 hr |
Safety and Regulatory | CAT III 1500V IEC 61010-1: Pollution Degree 2 |
|
Warning Features | Over-voltage, over-current, over-temperature, reverse polarity |
|
PV Connector | Staubli MC4-EVO2 | Banana Jacks |
Charging/Charged LED | Yes | |
In-the-field firmware update-ready | Yes | |
Interface to Tablet/Laptop | Wi-Fi interface between user tablet or laptop, I-V unit and SolSensorâ„¢ |
|
Weight | 6.6 kg, 14.55 lb | 7.3 kg, 16.09 lb |
Height | 43.2 cm, 1.41 ft (including test lead and strain reliefs) | 53.3 cm, 1.74 ft |
Width | 21.6 cm, 8.50 in | |
Depth | 15.2 cm, 5.98 in |
PVA-1500 Test Lead and Clip Specifications | |
Voltage Range | 0 to 1500V DC |
Current Range | 0 to 30A DC |
Temperature | 0 °C to 45 °C, 32 °F to 113 °F |
Humidity | Maximum relative humidity of 80% for temperatures up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F) |
Pollution Degree | 2 |
Altitude | 2000 m, 6561 ft maximum |
Lead Length | 152 cm, 59.84 in |
Lead Colors | Positive=red, negative=black |
Manufacturer (Test Leads and Alligator Clips) | Staubli |
Note: Use only test leads and clips provided by Fluke for the PVA-1500. | |
SolSensorâ„¢ Specifications | |
Irradiance | |
Sensor Type | Silicon photodiode with corrections for temperature, spectral, and angular effects |
Measurement Range | 100 W/m² to 1500 W/m² |
Accuracy | ±2 % when used to predict the performance of well characterized poly- and monocrystalline PV modules with direct irradiance >600W/m² |
Resolution | 1 W/m² |
Measurement Interval | Typically, 3.5 s |
Temperature | |
Sensor Type | Type K thermocouple, two inputs |
Measurement Range | 0 °C to 100 °C, 32 °F to 212 °F |
Accuracy | ±2 °C, 35.6 °F (not including limits of error of thermocouple) |
Resolution | 0.1 °C, 32.18 °F |
Measurement Interval | Typically, 3.5 s |
Tilt | |
Sensor Type | Electronic |
Measurement Range | 0 to 90° from horizontal |
Accuracy | ±2° typical (0 to 45°) |
General | |
Measurement Cynchronization with I-V Curve | Typically, <1 s |
Wireless Range (open line of sight) | 100 m, 328 ft |
Operating Temperature Range | 0 ºC to 45 ºC, 32 ºF to 113 ºF |
Storage Temperature Range | -20 ºC to 65 ºC, -4 ºF to 149 ºF |
Operating Humidity | <90% RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used. |
Battery Charging Time | 6 hr |
Battery Run Time | >16 hr typical use |