Fluke RSE600 : An Astonishing Mounted Infrared Camera
Short Description:
Fluke RSE600-Mounted Infrared Camera
- MATLAB® and LabVIEW® software program compatibility permits customers to combine infrared data, pictures and motion pictures to aid R&D analysis
- 640 x 480 resolution
- See the information you want with non-obligatory clever lenses: 2x and 4x telephoto, huge attitude and macro lenses
- Optimize pictures, generate customizable reviews and export pictures to the layout of your preference
- with SmartView® laptop software program
- Wirelessly join your digital digicam to the Fluke Connect® device to without difficulty proportion and edit pictures
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
14
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke RSE600 Mounted Infrared Camera
Fluke RSE600 Thermal Imager (the Product or Imager) is a stationary, infrared imaging camera to be used in lots of programs. These programs consist of system troubleshooting, preventive and predictive maintenance, constructing diagnostics, and research and development.
Introducing Fluke RSE600: An Infrared Camera With Brilliant Functions
Introducing the primary ever fully-radiometric, established Fluke infrared cameras – the RSE series. Equipped with superior functions and software program plug-ins to MATLAB® and LabVIEW®, those equipment are perfect for constantly streaming and reading infrared data
How To Set Up Your Fluke RSE300 or RSE600Â
Fluke RSE600Â Features
- MATLAB® and LabVIEW® software program compatibility permits customers to combine infrared data, pictures, and motion pictures to aid R&D analysis
- 640 x 480 resolution
- See the information you want with non-obligatory clever lenses: 2x and 4x telephoto, huge attitude, and macro lenses
- Optimize pictures, generate customizable reviews, and export pictures to the layout of your preference with the SmartView® laptop software program
- Wirelessly join your digital digicam to the Fluke Connect® device without difficulty proportion and edit pictures
Application Fluke RSE600
- Designed for your research, technology, and engineering needs, beautify you’re trying out and exceptional guarantee processes through mounting the RSE600 in your workstation.
- Continuously move as many as 60 frames of facts in keeping with 2nd without delay in your laptop to screen minute temperature differences, and examine motion pictures body-through-body remotely from the SmartView® computing device software program.
- Enhance your viewing revel with non-compulsory add-on lenses to goal-exclusive applications (reading from a distance, or getting the close-up details).
How to work with Fluke RSE600?
The Imager and SmartView R&D want a strong community connection to work properly. Set up your community without interference from different systems.
Do now no longer join the Imager to a VirtualPrivate Network (VPN). SmartView R&D is a data-in-depth application. The use of different data-intensive applications (streaming audio or video) on the PC or the equal community device can motivate a lack of data.
Note
All thermal imagers want enough heat-up time for correct temperature measurements and pleasant picture quality. Fluke recommends a heat-up length of 60 mins for the highest quality performance. To install the Fluke RSE600 you must:
1. Attach the antenna.
2. Stabilize the Product both on a flat floor or a tripod.
3. Connect the M12 quit of the ethernet cable to the M12 ethernet jack at the Product. See Figure 1.
a. Fully insert the ethernet cable into the ethernet jack.
b. Rotate the hoop one hundred eighty º clockwise. Connect the M12 connector quit of the ethernet cable
to the Product
4. Connect the RJ45 connector quit of the ethernet cable to the ethernet jack at the PC. See Figure 2.
5. Connect the AC plug of the M16 DC energy cable (15 V dc) to an energy outlet and the M16
connector to the Product.
6. Wait for the Product to heat up and the LED indicator to expose stable green.
7. Remove the lens cover.
8. Use SmartView R&D to awareness of the picture.
 Warning you need to know before using Fluke RSE600
To save you a feasible electric shock, fire, or non-public injury and for secure operation of the Product:
• Read all protection facts earlier than you operate the Product.
• Carefully examine all instructions.
• Do now no longer regulate the Product and use simplest as targeted, or the
safety furnished via way of means of the Product may be compromised.
• Do now no longer use the Product if it operates incorrectly.
• Do now no longer use the Product if it’s miles altered or damaged.
• Disable the Product if it’s miles damaged.
• Do now no longer place steel gadgets into connectors.
• Use the simplest targeted alternative parts
What is a warmness sink and why is it essential Fluke RSE600?
A warmness sink is a not unusual place element in lots of digital devices. It transfers the warmth created with the aid of using a device, performing to lessen the device’s temperature to save you from overheating.
Heat sinks are an essential part of LED lighting, extra particularly LED chips.
The warmness sink aids in the warmness dissipation of the chip, making sure that the temperature of those chips remains inside the precise range. Testing warmness sinks withinside the manufacturing technique of LED chips is crucial to make sure quality.
Infrared cameras may be used withinside the R&D technique to test LED warmness sinks. The readings from a digital digicam can assist producers in discoverability issues with substances and designs, to higher examine and enhance warmness sink quality.
Specifications Fluke RSE600 Camera :
- Detector resolution: 640 x 480 (307,200 pixels)
- Field of view: 34 °H x 25.5 °V
- Wireless connectivity: Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN
- Thermal sensitivity : ≤ 0.040 °C at 30 °C target temp
- Frame rate: 60 Hz or 9 Hz versions
- Digital zoom: Variable up to 16x in SmartView® desktop software
- Temperature measurement range : -10 °C to +1200 °C (14 °F to +2192 °F)
- Accuracy : ± 2 °C or ± 2 %
- Operating temperature : -10 °C to +50 °C (14 °F to 122 °F)
- Infrared spectral band: 8 μm to 14 μm (long wave)
- Size (H x W x L) : 8.3 x 8.3 x 16.5 cm (3.3 x 3.3 x 6.5 in)
- Weight (battery not included): 1 kg (2.2 lb)
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Fluke RSE600 : An Astonishing Mounted Infrared Camera
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Related Products
Testo 871 Building Diagnosis Kit-Bluetooth Probe 605i
Rated 5.00 out of 5
In stock
AED 10,163 (excl.VAT)
DENNY –
Best Resolution