Megger MFT1700 Multifunction Tester
Looking to buy Megger MFT1700 in Dubai, UAE? Find competitive prices and exceptional quality here!
MME Shopping Event
Hurry and get discounts on Most of MME Products up to 20%
Call for Price
Megger MFT1700 Multifunction Tester
The Megger MFT1700 Multifunction Tester is a versatile and robust instrument designed for testing the electrical safety and performance of various electrical installations. This tester is widely used in domestic, commercial, and industrial environments for tasks such as insulation resistance testing, loop impedance measurement, RCD testing, and voltage detection.
The MFT1710 is a basic model designed for 17th Edition testing, featuring CAT IV safety, and offers both 3 and 2-wire non-trip loop testing that displays resistance and fault current. It also measures frequency and boasts the market’s largest, brightest, and most easily readable display.
Megger MFT1700 Key Features
- Two and three wire non trip loop testing for fast repeatable results
- Large bright LCD display showing dual parameters – loop resistance and fault current, insulation resistance and test voltage
- Phase rotation indication for verification of rotating machinery
- 3-phase RCD testing for industrial applications with no earth
- 3-terminal earth test for electrode resistance measurement
- On-board data storage and Bluetooth® download
Megger MFT1700 Specifications
Test Type | Specification Detail | Range and Accuracy |
---|---|---|
Insulation Test | Voltage Levels: 100V, 250V, 500V, 1000V | 10 kΩ – 999 MΩ (1000V range) ±3% ±2 digits |
10 kΩ – 500 MΩ (500V) ±3% ±2 digits, >500 MΩ ±10% ±4 digits | ||
10 kΩ – 250 MΩ (250V) ±3% ±2 digits, >250 MΩ ±10% ±4 digits | ||
10 kΩ – 100 MΩ (100V) ±3% ±2 digits, >100 MΩ ±10% ±4 digits | ||
Voltage Display: | ±3% ±3 digits ±0.5% of rated voltage | |
Max Service Error: | ±15% ±2 digits | |
Short Circuit Current: | 1.5 mA nominal | |
Test Current on Load: | ≥1 mA at min pass values | |
Output Voltage Tolerance: | -0% +20% at rated load or less | |
Continuity / Resistance | 0.01 Ω to 99.9 kΩ | |
Intrinsic Accuracy: | ±2% ±2 digits (0.01 Ω to 99.9 Ω) | |
±5% ±2 digits (100 Ω to 99.9 kΩ) | ||
Open Circuit Voltage: | 5 V ±1 V | |
Test Current (200 mA Range): | >200 mA @ ≤2 Ω | |
Test Current (15 mA Range): | >15 mA @ ≤2 Ω | |
Max Service Error: | ±12% ±2 digits | |
Loop Test 2Hi (L-PE, L-N, L-L) | 0.01 Ω to 1000 Ω | |
Intrinsic Accuracy: | ±5% ±3 digits | |
Supply: | 48 V to 480 V* (45 Hz to 65 Hz) *MFT1711 280 V | |
Test Current High: | 4.0 A (at 230 V) | |
PSCC Range: | 20 kA | |
Loop Test 3Lo, 2Lo (L-E) | 0.01 Ω to 1000 Ω | |
Intrinsic Accuracy: | 0.01 Ω to 39.9 Ω ±5% ±5 digits, 40.0 Ω to 999 Ω ±10% ±5 digits | |
Supply: | 48 V to 280 V (45 Hz to 65 Hz) | |
Test Current: | Pulsed | |
PFC Range: | 20 kA |
You must be logged in to post a review.
Brand
Megger
Megger
Megger since 1889 is a leading global premium manufacturer of measurement and testing technology. Megger top priority has always been to make your everyday work easier and safer. As such, insulation testers, micro-ohmmeters, and multimeters are among the long line of Megger inventions, making this brand one of the pioneers in the electrical industry. Megger products combine many years of experience and the valued feedback from our global users with the inventiveness and conscientiousness of our product developers. In Germany, we manufacture at three sites, Aachen, and Baunach near Bamberg and Radeburg near Dresden. Other manufacturing locations are based in Sweden, England, and America.
Specifications
Test Type | Specification Detail | Range and Accuracy |
---|---|---|
Insulation Test | Voltage Levels: 100V, 250V, 500V, 1000V | 10 kΩ – 999 MΩ (1000V range) ±3% ±2 digits |
10 kΩ – 500 MΩ (500V) ±3% ±2 digits, >500 MΩ ±10% ±4 digits | ||
10 kΩ – 250 MΩ (250V) ±3% ±2 digits, >250 MΩ ±10% ±4 digits | ||
10 kΩ – 100 MΩ (100V) ±3% ±2 digits, >100 MΩ ±10% ±4 digits | ||
Voltage Display: | ±3% ±3 digits ±0.5% of rated voltage | |
Max Service Error: | ±15% ±2 digits | |
Short Circuit Current: | 1.5 mA nominal | |
Test Current on Load: | ≥1 mA at min pass values | |
Output Voltage Tolerance: | -0% +20% at rated load or less | |
Continuity / Resistance | 0.01 Ω to 99.9 kΩ | |
Intrinsic Accuracy: | ±2% ±2 digits (0.01 Ω to 99.9 Ω) | |
±5% ±2 digits (100 Ω to 99.9 kΩ) | ||
Open Circuit Voltage: | 5 V ±1 V | |
Test Current (200 mA Range): | >200 mA @ ≤2 Ω | |
Test Current (15 mA Range): | >15 mA @ ≤2 Ω | |
Max Service Error: | ±12% ±2 digits | |
Loop Test 2Hi (L-PE, L-N, L-L) | 0.01 Ω to 1000 Ω | |
Intrinsic Accuracy: | ±5% ±3 digits | |
Supply: | 48 V to 480 V* (45 Hz to 65 Hz) *MFT1711 280 V | |
Test Current High: | 4.0 A (at 230 V) | |
PSCC Range: | 20 kA | |
Loop Test 3Lo, 2Lo (L-E) | 0.01 Ω to 1000 Ω | |
Intrinsic Accuracy: | 0.01 Ω to 39.9 Ω ±5% ±5 digits, 40.0 Ω to 999 Ω ±10% ±5 digits | |
Supply: | 48 V to 280 V (45 Hz to 65 Hz) | |
Test Current: | Pulsed | |
PFC Range: | 20 kA |
Specifications
Related Products
Fluke 279 FC True-rms Thermal Multimeter
In stock
FLUKE 393 FC : an epic True-rms Clamp Meter with iFlex
In stock
Fluke 368 FC Leakage Current Clamp Meter
In stock
Fluke 375 AC/DC Clamp Meter
In stock
Fluke 179 True RMS Digital Multimeter
In stock
Fluke 77 IV Digital Multimeter
In stock
FLUKE 117 An Excellent Electricians Multimeter
In stock
Reviews
Clear filtersThere are no reviews yet.