Fluke 572-2 Infrared Thermometer
- Dual infrared and K-type thermocouple measurement capabilities
- Wide temperature range from -30°C to 900°C
- Digitally adjustable emissivity from 0.10 to 1.00
- Dual laser sighting for precise targeting
- Hi/low alarms with Min/Max/Avg/Dif functions
- USB 2.0 data communication and 99-point data storage
- Dot matrix display with switchable Celsius/Fahrenheit
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 572-2 Infrared Thermometer is a versatile handheld instrument designed for professionals who need reliable temperature measurement across both non-contact infrared and contact K-type thermocouple methods. Combining Fluke’s renowned build quality with a wide measurement range, this device serves technicians, engineers, and maintenance teams who require accurate readings in industrial, HVAC, and electrical applications. The dual-function design eliminates the need for carrying separate instruments, making it an essential tool for field service work where space and efficiency matter.
Fluke 572-2 Key Features
The Fluke 572-2 delivers comprehensive temperature measurement capabilities with its infrared sensing and K-type thermocouple input. The infrared function measures from -30°C to 900°C (-22°F to 1652°F) with digitally adjustable emissivity, while the K-type thermocouple input extends the range to -270°C to 1372°C (-454°F to 2501°F). Additional features include dual laser sighting for accurate targeting, Hi/low audible and visual alarms, and Min/Max/Avg/Dif measurement functions. The switchable Celsius/Fahrenheit display, two-level backlight, and USB 2.0 connectivity for data transfer make this instrument adaptable to various working environments and reporting requirements.
- Infrared temperature range: -30°C to 900°C (-22°F to 1652°F)
- IR accuracy: ±1°C or ±1% of reading (whichever greater) at ≥0°C
- IR repeatability: ±0.5% of reading or ±0.5°C (±1°F)
- Display resolution: 0.1°C / 0.1°F
- Distance-to-spot ratio: 60:1
- Minimum spot size: 19 mm
- Digitally adjustable emissivity: 0.10 to 1.00
- K-type thermocouple range: -270°C to 1372°C
- Hi/low alarms with two-color visual indicator
- Min/Max/Avg/Dif measurement functions
- USB 2.0 data communication
- 99-point data storage capacity
- Dot matrix 98 x 96 pixel display
- Two-level backlight (normal and extra bright)
- Switchable Celsius/Fahrenheit
- Trigger lock function
- Powered by 2 AA batteries
- Battery life: 8 hours with laser/backlight on, 100 hours off
Who Needs the Fluke 572-2?
Electrical maintenance technicians will find the Fluke 572-2 indispensable for inspecting connections, motors, and panels without direct contact, reducing safety risks while maintaining productivity. The infrared measurement capability allows for quick scanning of large areas to identify hot spots, while the K-type thermocouple input provides precise readings at specific points when probe access is available. This dual functionality makes it particularly valuable for preventive maintenance programs where both surface and contact temperatures need documentation.
HVAC engineers and facilities managers benefit from the Fluke 572-2’s ability to measure duct temperatures, refrigerant line conditions, and system performance metrics. The wide temperature range accommodates everything from cold storage assessment to high-temperature motor monitoring, and the switchable temperature units simplify documentation for diverse project requirements. The data storage function allows technicians to capture and review readings later, supporting trend analysis and compliance reporting.
Field service engineers appreciate the Fluke 572-2’s rugged construction and versatile measurement options in a single handheld device. The dual laser sighting improves targeting accuracy, while the backlight function ensures readability in dimly lit electrical panels or mechanical rooms. The audible and two-color visual alarms provide immediate feedback on temperature thresholds, helping prioritize maintenance actions and prevent equipment failures before they occur.
Fluke 572-2 Applications
In electrical substation maintenance, the Fluke 572-2 enables technicians to scan busbars, connections, and equipment for abnormal heating patterns that may indicate loose contacts or overloaded circuits. The infrared function provides rapid area scanning, while the K-type input allows verification of specific connection temperatures. This combination helps reduce downtime and prevent catastrophic equipment failures through early detection of thermal anomalies.
HVAC system commissioning and troubleshooting applications include measuring supply and return air temperatures, checking refrigerant line temperatures, and verifying heat exchanger performance. The wide temperature range accommodates both chilled water systems and high-temperature heating applications, while the emissivity adjustment ensures accurate readings on various duct materials and surfaces. The data storage capability supports documentation of system performance for commission reports and future maintenance planning.
Why Buy Fluke 572-2 from mme-ae?
Mohammad Mahdi Electronics, operating as mme-ae, provides genuine Fluke instruments with full manufacturer warranty and authentic calibration documentation. Our team ensures every Fluke 572-2 thermometer undergoes quality verification before shipment, giving customers confidence in measurement accuracy and instrument reliability. We stock a comprehensive range of Fluke test and measurement equipment, supported by knowledgeable technical assistance to help you select the right tool for your specific application needs.
When you purchase from mme-ae, you benefit from genuine product sourcing, prompt delivery across the UAE, and access to Fluke’s extensive support resources. Our commitment to customer satisfaction means you receive not just a measurement instrument, but a reliable partnership for your temperature monitoring requirements. Contact our sales team to discuss your Fluke 572-2 requirements and discover how this versatile thermometer can support your operational efficiency.
For immediate availability and competitive pricing on the Fluke 572-2 Infrared Thermometer, contact Mohammad Mahdi Electronics today. Our friendly staff are ready to assist you with product selection, warranty information, and delivery options tailored to your schedule. We understand the importance of having the right measurement tools when you need them, and we strive to make your purchasing experience smooth and straightforward from inquiry to delivery.
Fluke 572-2 Specifications
| Infrared Measurements | |
| Infrared temperature range | -30°C to 900°C (-22°F to 1652°F) |
| IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C) | ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater |
| ≥ -10°C to < 0°C: ±2°C | |
| < -10°C: ±3°C | |
| ≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater | |
| ≥ 14°F to < 32°F: ±4°F | |
| < 14°F: ±6°F | |
| IR repeatability | ±0.5% of reading or ±0.5°C (±1°F), whichever is greater |
| Display resolution | 0.1°C / 0.1°F |
| Distance: Spot | 60:1 (calculated at 90% energy) |
| Minimum spot size | 19 mm |
| Laser sighting | Offset dual laser, output < 1 mW |
| Spectral response | 8 μm to 14 μm |
| Response time (95%) | < 500 ms |
| Emissivity | Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
| Contact Measurements | |
| K-type thermocouple input temperature range | -270°C to 1372°C (-454°F to 2501°F) |
| K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C) | < -40°C: ±(1°C + 0.2° / 1°C) |
| ≥ -40°C: ±1% or 1°C, whichever is greater | |
| < -40°F: ±(2°F + 0.2° / 1°F) | |
| ≥ -40°F: ±1% or 2°F, whichever is greater | |
| K-type thermocouple | 0.1°C / 0.1°F |
| K-type thermocouple repeatability | ±0.5% of reading or ±0.5°C (±1°F), whichever is greater |
| Measurement Options | |
| Hi/Low alarms | Audible and two-color visual |
| Min/Max/Avg/Dif | Yes |
| Switchable celsius and fahrenheit | Yes |
| Backlight | Two levels, normal and extra bright for darker environments |
| Probe input | K-type thermocouple simultaneous display of probe and IR temperature |
| Trigger lock | Yes |
| Data storage | 99 points |
| Display | Dot matrix 98 x 96 pixels with function menus |
| Communication | USB 2.0 |
| K-Type Thermocouple Specifications | |
| Measurement range (bead probe) | -40°C to 260°C (-40°F to 500°F) |
| Accuracy | ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) |
| Cable length | 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
| General Specifications | |
| Safety and compliance | IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 |
| Operating temperature | 0°C to 50°C (32°F to 122°F) |
| Storage temperature | -20°C to 60°C (-4°F to 140°F) |
| Relative humidity | 10% to 90% RH non-condensing up to 30°C (86°F) |
| Operating altitude | 2000 meters above mean sea level |
| Weight | 0.322 kg (0.7099 lb) |
| Power | 2 AA batteries |
| Battery life | 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on) |