Fluke TC03A 9HZ Thermal Camera
- 384 x 288 IR resolution with SuperResolution up to 768 x 576
- 9 Hz frame rate for real-time thermal monitoring
- Manual focusing with 10.5 mm focal length lens
- Temperature range from -20 ℃ to 550 ℓ
- ±2% accuracy or ±2°C, whichever is greater
- Android and HarmonyOS compatibility
- IP54 ingress protection for rugged field use
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke TC03A 9HZ is a compact, handheld thermal camera designed for professionals who need reliable temperature measurement in the field. With its infrared resolution of 384 x 288 pixels and SuperResolution technology that enhances detail up to 768 x 576, this device delivers clear thermal imagery for a wide range of applications. The camera operates across a broad temperature range of -20 ℃ to 550 ℃ with ±2% accuracy, making it suitable for electrical inspections, HVAC maintenance, and industrial troubleshooting. Its Android and HarmonyOS compatibility ensures seamless integration with modern mobile devices, while the manual focusing system and 10.5 mm focal length lens provide flexibility when capturing images at various distances.
Fluke TC03A 9HZ Key Features
The Fluke TC03A 9HZ combines advanced thermal imaging technology with user-friendly features in a lightweight package. Weighing just 55 grams and measuring 60 mm x 36 mm x 28 mm, it is highly portable for on-the-go inspections. The manual focusing mode gives users control over image clarity, while the 9 Hz frame rate ensures smooth thermal video playback. Additional features include manual and automatic Nonuniformity Correction (NUC), a spectral range of 8 to 14 μm, and IP54 ingress protection with the protective cover installed, making it durable in challenging work environments.
- IR Resolution: 384 x 288
- SuperResolution: Up to 768 x 576
- Pixel Size: 12 μm
- Temperature Range: -20 ℃ to 150 ℃, 100 ℃ to 550 ℃
- Temperature Accuracy: ±2% of reading or ±2 °C, whichever is greater
- Frame Rate: 9 Hz
- Focal Length: 10.5 mm
- Focusing Mode: Manual
- Nonuniformity Correction: Manual / Auto
- Thermal Sensitivity (NETD): 50 mK
- Spectral Range: 8 to 14 μm
- Field of View: 25° x 19°
- Spatial Resolution: 1.14 mrad
- USB Interface: Type C
- Operating System: Android and HarmonyOS
- Operating Temperature: 0℃ to 40 ℃
- Storage Temperature: -30 ℃ to 60 ℃
- Operating Humidity: 10% to 90% RH (non-condensing)
- Power Consumption: 700 mW (Typical)
- Ingress Protection: IP54 (with protective cover for Type-C)
- Operating Altitude: 2000 m
- Storage Altitude: 12000 m
- Dimensions: 60 mm x 36 mm x 28 mm
- Weight: 55 g
- Warranty: 2 years
Who Needs the Fluke TC03A 9HZ?
Electrical technicians and maintenance engineers will find the Fluke TC03A 9HZ indispensable for preventive maintenance programs. The camera’s ability to quickly identify hot spots in electrical panels, motors, and connections helps prevent unexpected downtime and equipment failure. By visualizing thermal patterns, professionals can detect issues before they become critical, saving time and repair costs. The compact design and robust IP54 rating make it ideal for field work where durability and portability are essential requirements.
HVAC professionals and building services teams can leverage the Fluke TC03A 9HZ for system optimization and troubleshooting. Whether checking for heat loss in insulation, verifying HVAC duct performance, or identifying overheating components in building management systems, this thermal camera provides the visual data needed to make informed decisions. The wide temperature range accommodates various HVAC applications, from residential installations to complex commercial systems, while the Android compatibility allows for easy report generation and sharing on-site.
Quality control inspectors and research professionals will appreciate the Fluke TC03A 9HZ’s precision and reliability. The ±2% temperature accuracy and 50 mK thermal sensitivity ensure that even subtle temperature variations are detected and documented. This makes the camera suitable for laboratory settings, product development quality assurance, and research applications where precise thermal data is crucial for analysis and reporting purposes.
Fluke TC03A 9HZ Applications
The Fluke TC03A 9HZ excels in electrical preventive maintenance, where identifying overheating components is critical for safety and efficiency. Electricians can scan circuit breakers, fuses, and busbars to detect loose connections or overloaded circuits that are not visible to the naked eye. Regular thermal inspections help maintenance teams prioritize repairs and extend equipment lifespan. The camera’s fast 9 Hz frame rate allows for real-time monitoring of electrical systems during operation, providing immediate feedback on system performance.
In building diagnostics and energy audits, the Fluke TC03A 9HZ serves as a valuable tool for identifying thermal inefficiencies. Building inspectors can use the camera to locate air leaks, missing insulation, and thermal bridges in building envelopes. This information helps property owners and facility managers improve energy efficiency and reduce heating and cooling costs. The 25° x 19° field of view provides adequate coverage for room-scale inspections, while the SuperResolution feature enhances detail for more accurate assessments.
Why Buy Fluke TC03A 9HZ from mme-ae?
When you purchase the Fluke TC03A 9HZ from mme-ae, you are choosing a trusted source for genuine Fluke products in the UAE. Mohammad Mahdi Electronics, operating as mme-ae, ensures that every thermal camera is authentic and comes with the manufacturer’s full 2-year warranty. Our team of specialists is available to provide technical support and help you understand the camera’s features for your specific application needs. We prioritize customer satisfaction and aim to make your purchasing experience smooth and reliable.
Our commitment to quality extends beyond the point of sale. mme-ae provides comprehensive after-sales support, including product registration assistance and warranty claim processing. We understand that investing in professional testing equipment requires confidence, and we stand behind the Fluke TC03A 9HZ with our dedication to customer service. Choose mme-ae for your thermal imaging needs and experience the difference that genuine products and expert support can make.
with company name rotation.
Fluke TC03A 9HZ Specifications
| Models | TC03A/9Hz | TC03A/25Hz | TC03A PRO/50Hz |
| IR Resolution | 384 x 288 | ||
| SuperResolution | Yes, up to 768 x 576 | ||
| Pixel size | 12 μm | ||
| Temperature range | -20 ℃ to 150 ℃, 100 ℃ to 550 ℃ | ||
| Temperature accuracy | ± 2% of rdg. or ± 2 °C, whichever is greater | ||
| (@ 23 °C ± 5 °C ambient temperature) | |||
| Frame rate | 9 Hz | 25 Hz | 50 Hz |
| Focal length | 10.5 mm | ||
| Focusing mode | Manual | ||
| Nonuniformity Correction (NUC) | Manual / Auto | ||
| Thermal sensitivity (NETD) | 50 mK | 45 mK | |
| Spectral range | 8 to 14 μm | ||
| Field of View (FOV) | 25° x 19° | ||
| Spatial Resolution (IFOV) | 1.14 mrad | ||
| USB Interface | Type C | ||
| Operating system supported | Android and HarmonyOS | ||
| Operating temperature | 0℃ to 40 ℃ | ||
| Storage temperature | -30 ℃ to 60 ℃ | ||
| Operating humidity | 10% to 90% RH (non-condensing) | ||
| Power consumption | 700 mW (Typical) | ||
| Ingress protection | IEC 60529: IP54 (with the protective cover for Type-C) | ||
| Operating altitude | 2000 m | ||
| Storage altitude | 12000 m | ||
| Dimensions (L x W x H) | 60 mm x 36 mm x 28 mm | ||
| Weight | 55 g | ||
| Warranty | 2 years | ||
| EMC Environment | International IEC 61326-1: Electromagnetic environment for portable equipments CISPR 11: Group 1, Class A Group 1: Equipment intentionally generates and/or uses conductive-coupled RF energy, which is necessary for its internal operation. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Device meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. United States (FCC) 47 CFR Part 15 Subpart B. This product is considered an exempt device per clause 15.103. |
||
Datasheet
Datasheet
User Manual
User Manual
Reviews (0)
You must be logged in to post a review.
Bench Multimeters