Eurotron MPM-26 Multifunction Process Meter

Short Description:

Get the best deals on Eurotron MPM-26 in Dubai, UAE. Buy now and experience top-notch quality.

Product purchase
SKU: 87519
Brand:Eurotron

Call for Best Price 00971(04) 447 6031 00971(04) 344 9868

11 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
Description

Eurotron MPM-26 Multifunction Process Meter

The Eurotron MPM-26 is the ultimate troubleshooting tool for electricians and process control professionals, merging the capabilities of a comprehensive multifunction process calibrator with the robustness of a CAT III 1000 V, CAT IV 600 V safety-rated digital multimeter.

Additionally, the Eurotron MPM-26 features an integrated 24-Volt loop supply, eliminating the need for a separate power source during offline transmitter testing, and a built-in, selectable 250-ohm HART® resistor, removing the necessity for an additional resistor.

The MPM-26 is capable of measuring, sourcing, and simulating 4-20 mA signals. It can also measure resistance, power, provide power to the loop, and include a 250-ohm resistance in the loop. It features Span Check, along with 25% and 100% buttons for quick toggling between 4 and 20 mA sourcing. The display simultaneously shows mA and percentage of scale readings, facilitating faster troubleshooting.

Additionally, the MPM-26 offers comprehensive DMM functionalities such as frequency measurement up to 100 kHz, and modes for Min/Max/Average/Hold/Relative readings, as well as diode testing, a continuity beeper, and a capacitance meter. This makes it a versatile tool for troubleshooting all parts of the loop.

Eurotron MPM-26 Key Features

  • Compact Multi-function Process Calibrator and True RMS DMM
  • Measure and Source : mA, V, RTD’s, TC’s, Frequency
  • Built-in 24 VDC Loop Power Supply and 250 Ω Hart Resistor
  • Large, bright dual-measurement display
  • Complies with 600V CAT.IV, 1000V CAT.III safety standards
  • 0-1000 V AC (true-rms) or DC

Eurotron MPM-26 Specifications

 

measurement function range measurement range resolution accuracy remark
DC voltage 50mV -55.00mV~55.00mV 0.01mV 0.1%+4 Input resistance: about 100MΩ
500mV -550.0mV~550.0mV 0.1mV 0.1%+4
DCV 5V -5.500V~5.500V 0.001V 0.1%+4 Input resistance: 10MΩ
50V -55.00V~55.00V 0.01V 0.1%+4
500V -550.0V~550.0V 0.1V 0.1%+4
1000V -1000V~1000V 1V 0.1%+4
AC voltage 5V 0~5.500V 0.001V 0.5%+4 Input resistance: 10MΩ <100pF
ACV 50V 0~55.00V 0.01V 0.5%+4 20Hz~1kHz
500V 0~550.0V 0.1V 0.5%+4
1000V 0V~750V 1V 0.5%+4 10%~110% range
Ohms 500Ω 0~550.0Ω 0.1Ω 0.1%+4 test current: <0.8 mA
5KΩ 0~5.500KΩ 0.001KΩ 0.1%+4
OHM 50KΩ 0~55.00KΩ 0.01KΩ 0.1%+4 open-circuit voltage: <2.5V
500KΩ 0~550.0KΩ 0.1KΩ 0.1%+4
5MΩ 0~5.500 MΩ 0.001MΩ 1%+4
50MΩ 0~55.00 MΩ 0.01MΩ 1%+4
DC current 50mA -55.000mA~55.000mA 0.001mA 0.1%+5 Voltage Drop
DCI <1.8 mV/mA
500mA -500.00mA~500.00mA 0.01mA 0.1%+5 response time: ≤1S
AC current 50mA 0.000mA~55.000mA 0.001mA 0.5%+10 Voltage Drop
ACI <1.8 mV/mA
500mA 0.00mA~500.00mA 0.01mA 0.5%+10 response time: ≤3S
frequency 10Hz 0~9.9999Hz 0.0001Hz 0.02%+4
100Hz 0~99.999Hz 0.001Hz 0.02%+4
FREQ 1000Hz 0~999.99Hz 0.01Hz 0.02%+4
10kHz 0~9.9999kHz 0.0001kHz 0.02%+4
100kHz 0~99.999kHz 0.001kHz 0.02%+4
duty ratio 0.1%~99% 0.10% 1%
DUTY
Diode 2V 0.0001V 1%+10
DIODE
Continuity test 500Ω 0.1Ω ≤100ΩBB
COUNT
R -40°C~1760°C 1°C 0.5%+3°C(≤100)°C Employ ITS-90 temperature standard
S -200°C~1760°C
Thermal couple B 400°C~1800°C 0.5%+2°C(>100)°C Errors for cold-end compensation is excluded in the accuracy
K -200°C~1350°C 0.5%+2°C(≤-100)°C
TC E -200°C~700°C Errors for Thermoelectric potential is excluded in the accuracy
J -200°C~950°C 0.5%+1°C(>-100)°C
T -200°C~400°C
N -200°C~1300°C
Resistance temperature Cu50 -50°C~150°C 1°C 0.5%+3°C Employ Pt100-385 temperature standard.
RTD Measured current: about 0.8mA.
Open circuit voltage: about 2V.
Pt100 -200°C~850°C Wire resistance is excluded in the accuracy.
CAP 10nF 0~11.00nF 0.01nF 5%+50
100nF 0~110.0nF 0.1nF 5%+5
capacity 1000nF 0~1100nF 1nF 5%+5
10µF 0~11.00µF 0.01uF 5%+5
100µF 0~110.0µF 0.1uF 5%+5
1000µF 0~1100µF 1uF 5%+50
10mF 0~11.00mF 0.01mF 5%+50
100mF 0~110.0mF 0.1mF 5%+50
Simulate output function [adapt to one year after calibration 23℃±5℃,20~70% RH,accuracy=±(% settings + bytes)]
measurement function range Output setting range resolution accuracy remark
DC voltage 100mV -10.00~110.00mV 10μV 0.2%+4 Max output current: 0.5mA
1000mV -100.0~1100.0mV 100μV 0.2%+4 Max output current: 2mA
DCV 10V -1.000~11.000V 1mV 0.2%+4 Max output current: 5mA
DC current 30mA 0.000~33.000mA 0.001mA 0.2%+4 20mA max load 1KΩ
DCI 30mA max load 600Ω
simulate transmitter –30mA 0.000~–33.000mA 0.001mA
SIMULATE
Loop power 24V ±10% Max output current: 35mA
LOOP
Ohms 400Ω 0.0Ω~400.0Ω 0.1Ω 0.2%+4 Simulate current is±0.5~3mA
OHM When simulate current is±0.1~0.5mA,add additional 0.1Ω error.
wire resistance is excluded in the accuracy
Thermal couple R 0°C~1767°C 1°C 0.2%+3°C(≤100℃) Employ ITS-90 temperature standard.
S 0°C~1767°C
TC B 600°C~1820°C 0.2%+2°C(>100℃) Errors for cold-end compensation is excluded in the accuracy.
K -200.0°C~1372.0°C 0.1°C 0.2%+2°C(≤-100℃)
E -200.0°C~1000.0°C
J -200.0°C~1200.0°C 0.2%+1°C(>-100℃)
T -250.0°C~400.0°C
N -200.0°C~1300.0°C
Resistance temperature PT100 -0200.0~0850.0 0.1°C 0.2%+0.6°C Employ Pt100-385 temperature standard
RTD ±1mA simulate current
Cu50 -050.0~150.0 wire resistance is excluded in the accuracy
Frequency 100Hz 1.0Hz~110.0Hz 0.1Hz 0.2%+2 square wave
FREQ 50% duty ratio
1KHz 0.100KHz~1.100KHz 1Hz 0.2%+2
10KHz 1.0KHz~11.0KHz 0.1KHz 0.2%+2 1~11Vp-p
Loop Power Supply  24 VDC
Built in 250 Ω  YES
HART loop resistance
Display current and % of span  YES
25%,100%Step output  YES
Display Current & % of Span  YES
Auto Power Off  YES
Transmitter Simulation  YES
Overvoltage category IEC 61010-1 CAT III 1000 V
IEC 61010-1 CAT IV 600 V
Maximum Voltage  1000 V RMS
Power Supply 4×1.5V AA Alkaline battery
Dimensions 206×97×60
Weight 500g
Rating IP 65
Warranty  1 Year
Specifications

Specifications

Eurotron MPM-26 Specifications

measurement function range measurement range resolution accuracy remark
DC voltage 50mV -55.00mV~55.00mV 0.01mV 0.1%+4 Input resistance: about 100MΩ
500mV -550.0mV~550.0mV 0.1mV 0.1%+4
DCV 5V -5.500V~5.500V 0.001V 0.1%+4 Input resistance: 10MΩ
50V -55.00V~55.00V 0.01V 0.1%+4
500V -550.0V~550.0V 0.1V 0.1%+4
1000V -1000V~1000V 1V 0.1%+4
AC voltage 5V 0~5.500V 0.001V 0.5%+4 Input resistance: 10MΩ <100pF
ACV 50V 0~55.00V 0.01V 0.5%+4 20Hz~1kHz
500V 0~550.0V 0.1V 0.5%+4
1000V 0V~750V 1V 0.5%+4 10%~110% range
Ohms 500Ω 0~550.0Ω 0.1Ω 0.1%+4 test current: <0.8 mA
5KΩ 0~5.500KΩ 0.001KΩ 0.1%+4
OHM 50KΩ 0~55.00KΩ 0.01KΩ 0.1%+4 open-circuit voltage: <2.5V
500KΩ 0~550.0KΩ 0.1KΩ 0.1%+4
5MΩ 0~5.500 MΩ 0.001MΩ 1%+4
50MΩ 0~55.00 MΩ 0.01MΩ 1%+4
DC current 50mA -55.000mA~55.000mA 0.001mA 0.1%+5 Voltage Drop
DCI <1.8 mV/mA
500mA -500.00mA~500.00mA 0.01mA 0.1%+5 response time: ≤1S
AC current 50mA 0.000mA~55.000mA 0.001mA 0.5%+10 Voltage Drop
ACI <1.8 mV/mA
500mA 0.00mA~500.00mA 0.01mA 0.5%+10 response time: ≤3S
frequency 10Hz 0~9.9999Hz 0.0001Hz 0.02%+4
100Hz 0~99.999Hz 0.001Hz 0.02%+4
FREQ 1000Hz 0~999.99Hz 0.01Hz 0.02%+4
10kHz 0~9.9999kHz 0.0001kHz 0.02%+4
100kHz 0~99.999kHz 0.001kHz 0.02%+4
duty ratio 0.1%~99% 0.10% 1%
DUTY
Diode 2V 0.0001V 1%+10
DIODE
Continuity test 500Ω 0.1Ω ≤100ΩBB
COUNT
R -40°C~1760°C 1°C 0.5%+3°C(≤100)°C Employ ITS-90 temperature standard
S -200°C~1760°C
Thermal couple B 400°C~1800°C 0.5%+2°C(>100)°C Errors for cold-end compensation is excluded in the accuracy
K -200°C~1350°C 0.5%+2°C(≤-100)°C
TC E -200°C~700°C Errors for Thermoelectric potential is excluded in the accuracy
J -200°C~950°C 0.5%+1°C(>-100)°C
T -200°C~400°C
N -200°C~1300°C
Resistance temperature Cu50 -50°C~150°C 1°C 0.5%+3°C Employ Pt100-385 temperature standard.
RTD Measured current: about 0.8mA.
Open circuit voltage: about 2V.
Pt100 -200°C~850°C Wire resistance is excluded in the accuracy.
CAP 10nF 0~11.00nF 0.01nF 5%+50
100nF 0~110.0nF 0.1nF 5%+5
capacity 1000nF 0~1100nF 1nF 5%+5
10µF 0~11.00µF 0.01uF 5%+5
100µF 0~110.0µF 0.1uF 5%+5
1000µF 0~1100µF 1uF 5%+50
10mF 0~11.00mF 0.01mF 5%+50
100mF 0~110.0mF 0.1mF 5%+50
Simulate output function [adapt to one year after calibration 23℃±5℃,20~70% RH,accuracy=±(% settings + bytes)]
measurement function range Output setting range resolution accuracy remark
DC voltage 100mV -10.00~110.00mV 10μV 0.2%+4 Max output current: 0.5mA
1000mV -100.0~1100.0mV 100μV 0.2%+4 Max output current: 2mA
DCV 10V -1.000~11.000V 1mV 0.2%+4 Max output current: 5mA
DC current 30mA 0.000~33.000mA 0.001mA 0.2%+4 20mA max load 1KΩ
DCI 30mA max load 600Ω
simulate transmitter –30mA 0.000~–33.000mA 0.001mA
SIMULATE
Loop power 24V ±10% Max output current: 35mA
LOOP
Ohms 400Ω 0.0Ω~400.0Ω 0.1Ω 0.2%+4 Simulate current is±0.5~3mA
OHM When simulate current is±0.1~0.5mA,add additional 0.1Ω error.
wire resistance is excluded in the accuracy
Thermal couple R 0°C~1767°C 1°C 0.2%+3°C(≤100℃) Employ ITS-90 temperature standard.
S 0°C~1767°C
TC B 600°C~1820°C 0.2%+2°C(>100℃) Errors for cold-end compensation is excluded in the accuracy.
K -200.0°C~1372.0°C 0.1°C 0.2%+2°C(≤-100℃)
E -200.0°C~1000.0°C
J -200.0°C~1200.0°C 0.2%+1°C(>-100℃)
T -250.0°C~400.0°C
N -200.0°C~1300.0°C
Resistance temperature PT100 -0200.0~0850.0 0.1°C 0.2%+0.6°C Employ Pt100-385 temperature standard
RTD ±1mA simulate current
Cu50 -050.0~150.0 wire resistance is excluded in the accuracy
Frequency 100Hz 1.0Hz~110.0Hz 0.1Hz 0.2%+2 square wave
FREQ 50% duty ratio
1KHz 0.100KHz~1.100KHz 1Hz 0.2%+2
10KHz 1.0KHz~11.0KHz 0.1KHz 0.2%+2 1~11Vp-p
Loop Power Supply  24 VDC
Built in 250 Ω  YES
HART loop resistance
Display current and % of span  YES
25%,100%Step output  YES
Display Current & % of Span  YES
Auto Power Off  YES
Transmitter Simulation  YES
Overvoltage category IEC 61010-1 CAT III 1000 V
IEC 61010-1 CAT IV 600 V
Maximum Voltage  1000 V RMS
Power Supply 4×1.5V AA Alkaline battery
Dimensions 206×97×60
Weight 500g
Rating IP 65
Warranty  1 Year
Datasheet

Datasheet

Mme-Pdfs-Image