The lightweight, two-section design of Model Megger CB845 enables the user to easily transport the unit into areas previously inaccessible to high-current test equipment such as elevated or subsurface load centers, shipboard power panels, elevator machinery rooms, and other isolated locations.
MEGGER CB-845 Specifications:
- Input Voltage (switch-selected):208 and 240 V, 1f, 30 A
- Input Frequency (specify one):50 Hz O R 60 Hz
- Digital Display:31⁄2 digit, extra-bright LED display with 0.3 in. (7.62 mm) numerals
- Ranges (switch-selected):0 to 19.99/199.9/1999 A/10 kA
- Continuous Accuracy (overall ammeter system):±1% of reading, ±1 digit on three high ranges, ±1 digit on low range
- Control Units:11.25 H x 21.75 W x 17.5 D in. (29 H x 55 W x 44 D cm)
- Output Unit:11.25 H x 21.75 W x 19.5 D in. (29 H x 55 W x 49 D cm)
- Control Unit:69.25 lb (31.4 kg)
- Output Unit:(50 Hz): 123 lb (55.8 kg)
- Output Unit:(60 Hz): 103 lb (46.8 kg)
Specifications
Specifications
| Category | Specification | Details |
|---|---|---|
| Input | Input Voltage (switch-selected) | 208 and 240 V, 1f, 30 A |
| Input Frequency (specify one) | 50 Hz OR 60 Hz | |
| Output | Output Range | The output is continuously adjustable to accommodate a variety of test circuit impedances: 0 to 1200 A at 6 V max. |
| Output Capacity | The output circuit is designed to provide short-duration overloads. Capable of testing time-delay characteristics of devices rated up to 500 A using a test current of three times their rating (1500 A). For instantaneous trip tests, provides 5000 A through a typical 500 A molded-case circuit breaker. | |
| Overload Capability | Designed so that current ratings may be exceeded for short durations. Output current determined by load circuit impedance and voltage rating. | |
| Output Initiate | Initiate Circuit | The test set uses a solid-state output initiating circuit using a triac to increase reliability and eliminate contact maintenance. |
| Control Circuit | Provides momentary and maintained modes to control output duration. Used for short durations or maintained until manually turned off or the device under test operates. | |
| Timer | Description | A solid-state digital timer measures elapsed time in seconds or cycles, using a crystal controlled oscillator for accuracy independent of line frequency. |
| Display | Type | 5-digit, extra-bright LED display with 0.3 in. (7.62 mm) numerals |
| Accuracy and Ranges | Ranges (switch-selected) | 0 to 99.999 s, 0 to 999.99 s, 0 to 99999 cycles |
| Accuracy | ±0.005% of reading, ±1 digit |
Reviews (1)
Rated 0 out of 5
1 review
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Megger Cb-845 Circuit Breaker Test Set
Clear filters
Add a review Cancel reply
You must be logged in to post a review.


Bench Multimeters
sam –
The Megger Cb-845 is a reliable and efficient circuit breaker test set that has greatly improved our testing process!