Megger Power Transformer Test Van
- Insulation testing up to 15 kV (IR, DAR, PI, DD, SV)
- Winding resistance up to 10 A (optional 50 A)
- Tan Delta accuracy: 0.001% resolution with temp correction
- Turns ratio measurement range: 0.8 – 45000
- Includes PowerDB software for automated reporting
- Optional TravelPower generator (5 kVA) for site independence
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Megger Power transformer test van
To streamline your on-site assessment of power transformer condition the Megger transformer test van is equipped with a selection of instruments. It arrives on site ready for action to start testing, to rapidly yield and store results, and it even simplifies packing up for you.
The dedicated transformer test van helps you perform a range of routine electrical tests and advanced diagnostic techniques to international standards. Commissioning testing confirms that the system conforms to the design parameters, while the ongoing maintenance tests confirm that no changes are occurring, and confirm the safe uninterrupted operation of the power transformer and substation.
Megger Power Transformer Test Van
- Power supply: 100-240 V, 50-60 Hz, or three-phase (optional)
- Built-in power generator (optional): TravelPower: 5 kVA and higher
- Test leads: 30 m (optionally motorized)
- Insulation testing (IR, DAR, PI, DD, SV)
- Test voltage, DC: up to 5, 10, or 15 kV
- Range of measurement: 100 kOhm…15 TOhm
- Charging current: 2 mA, 6 mA (short circuit)
- Noise immunity: 8 mA
- Capacitance and dissipation factor (tan δ)
- Test voltage, AC : 0-12 kV
- Test current (at 12 kV): 300 mA (4 minutes), 100 mA (continuous)
- Test frequency range: 45-70 Hz (12 kV), 15-400 Hz (4 kV), 1-500 Hz (250 V)
- Measurement range of dielectric losses tan δ and capacitance : 0-100 (0-10,000%), (max. resolution 0.001%)0 -100 μF, (max. resolution 0.01 pF)
- Individual temperature correction of tan δ results from 5°C to 50°C insulation test temperature to 20 °C reference
- Noise immunity Electrostatic:15 mA, Electromagnetic 500 μT, at 50 Hz
Winding resistance and OLTC
- Core de-magnetization: Automatic
- Test current: up to 10 A (optional up to 50 A)
- Measurement range: 1 μOhm – 2 kOhm
- Accuracy : +/- 0,25%
Turns ratio and vector group
- Excitation voltage: up to 80 V
- Ratio measurement range: 0,8 – 45000
- Phase deviation: +/-90°
- Accuracy : +/-0,1%… +/- 0,3%
- No-load and short-circuit loss power (optional)
- 3-phase power multimeter : 0-650 V, 0-100 A, 10-1000 Hz, 0-100 kW
- 3-phase current regulating autotransformer: up to 16 A
- Voltage withstand testing (optional)
- AC 50 Hz test voltage : 0…100 kV
- DC test voltage : 0…70 kV
- Load capacitance: 0,01-1,9 nF
- Leakage current measurement: up to 100 mAMax.
- power consumption: 20 kVA
Frequency Response Analysis (optional)
Moisture in cellulose assessment (optional)
- Oil dielectric strength test set (optional): up to 100 kV
- Control & data acquisition & reporting: PowerDB, LabTransControl
- Basic operating system: WIN 7
- Interface: RS 232, USB, Ethernet
- Uninterruptable power supply for industrial PC: 7 min
2 reviews for Megger Power Transformer Test Van
Clear filtersYou must be logged in to post a review.


Bench Multimeters
mike –
great product
sam –
The Megger PTTV-8000 made on-site transformer testing remarkably efficient and reliable, exceeding all my expectations.