Megger Power Transformer Test Van

(1 customer review)

Short Description:

To stream-line your on-site assessment of power transformer condition the Megger Power Transformer Test Van is equipped with a selection of instruments. It arrives on site ready for action to start testing, to rapidly yield and store results, and it even simplifies packing up for you.

Product purchase
SKU: 5176 Category:
Brand:Megger

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

18 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE

Megger Power transformer test van

To streamline your on-site assessment of power transformer condition the Megger transformer test van is equipped with a selection of instruments. It arrives on site ready for action to start testing, to rapidly yield and store results, and it even simplifies packing up for you.

The dedicated transformer test van helps you perform a range of routine electrical tests and advanced diagnostic techniques to international standards. Commissioning testing confirms that the system conforms to the design parameters, while the ongoing maintenance tests confirm that no changes are occurring, and confirm the safe uninterrupted operation of the power transformer and substation.

Megger Power Transformer Test Van

  • Power supply: 100-240 V, 50-60 Hz, or three-phase (optional)
  • Built-in power generator (optional): TravelPower: 5 kVA and higher
  • Test leads: 30 m (optionally motorized)
  • Insulation testing (IR, DAR, PI, DD, SV)
  • Test voltage, DC: up to 5, 10, or 15 kV
  • Range of measurement: 100 kOhm…15 TOhm
  • Charging current: 2 mA, 6 mA (short circuit)
  • Noise immunity: 8 mA
  • Capacitance and dissipation factor (tan δ)
  • Test voltage, AC : 0-12 kV
  • Test current (at 12 kV): 300 mA (4 minutes), 100 mA (continuous)
  • Test frequency range: 45-70 Hz (12 kV), 15-400 Hz (4 kV), 1-500 Hz (250 V)
  • Measurement range of dielectric losses tan δ and capacitance : 0-100 (0-10,000%), (max. resolution 0.001%)0 -100 μF, (max. resolution 0.01 pF)
  • Individual temperature correction of tan δ results from 5°C to 50°C insulation test temperature to 20 °C reference
  • Noise immunity Electrostatic:15 mA, Electromagnetic 500 μT, at 50 Hz

Winding resistance and OLTC

  • Core de-magnetization: Automatic
  • Test current: up to 10 A (optional up to 50 A)
  • Measurement range: 1 μOhm – 2 kOhm
  • Accuracy : +/- 0,25%

Turns ratio and vector group

  • Excitation voltage: up to 80 V
  • Ratio measurement range: 0,8 – 45000
  • Phase deviation: +/-90°
  • Accuracy : +/-0,1%… +/- 0,3%
  • No-load and short-circuit loss power (optional)
  • 3-phase power multimeter : 0-650 V, 0-100 A, 10-1000 Hz, 0-100 kW
  • 3-phase current regulating autotransformer: up to 16 A
  • Voltage withstand testing (optional)
  • AC 50 Hz test voltage : 0…100 kV
  • DC test voltage : 0…70 kV
  • Load capacitance: 0,01-1,9 nF
  • Leakage current measurement: up to 100 mAMax.
  • power consumption: 20 kVA

Frequency Response Analysis (optional)

Moisture in cellulose assessment (optional)

  • Oil dielectric strength test set (optional): up to 100 kV
  • Control & data acquisition & reporting: PowerDB, LabTransControl
  • Basic operating system: WIN 7
  • Interface: RS 232, USB, Ethernet
  • Uninterruptable power supply for industrial PC: 7 min