The Milwaukee MW12 Digital Phosphate Tester is an essential tool for monitoring phosphate levels in water. With its digital accuracy and user-friendly design, it provides quick results for aquaculture, water treatment, and education professionals, helping to maintain safe and high-quality water standards for environmental health and sustainability.

  • Range: 0.00 to 2.50 ppm
  • Resolution: 0.01 ppm
  • Accuracy: ±0.04 ppm or 4% of reading @ 25 °C
Product purchase
SKU: 101938
Brand:Milwaukee

Call for Best Price 00971(04) 447 6031 00971(04) 344 9868

11 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
Description

Buy Milwaukee MW12

The Milwaukee MW12 Digital Phosphate Tester is a state-of-the-art tool designed to accurately measure phosphate levels in various water sources. This photometer is particularly beneficial for applications in aquaculture, water treatment, and educational settings, where precise monitoring of phosphate concentration is essential for maintaining water quality.

Advantages

The Milwaukee MW12 offers several key benefits that enhance its usability and effectiveness:

  • Digital Precision: Unlike traditional testing methods, the MW12 provides a digital readout that ensures accurate measurements of phosphate levels, eliminating the ambiguity often associated with colorimetric tests.
  • User-Friendly Interface: The device features a large LCD display that allows users to easily read results, making it accessible for both experienced professionals and those new to water quality testing.
  • Rapid Results: Users can expect quick results by simply adding the appropriate reagent to their water sample. This efficiency is crucial in environments where timely monitoring is necessary.
  • No Calibration Needed: The MW12 is designed for straightforward operation with no need for calibration, allowing users to focus on their testing without additional preparation.

Applications

The versatility of the Milwaukee MW12 makes it suitable for a wide range of applications:

  • Aquaculture: Monitoring phosphate levels is vital for maintaining healthy aquatic environments in fish farming and aquaculture operations. The
    MW12 enables producers to ensure optimal conditions for fish growth and health.
  • Water Treatment Facilities: Municipal and industrial water treatment plants utilize the MW12 to monitor phosphate concentrations, which can impact water quality and treatment efficacy.
  • Educational Institutions: The MW12 serves as an excellent educational tool in laboratories and classrooms, helping students learn about water quality analysis and the significance of phosphate testing in real-world scenarios.

Milwaukee MW12 Specifications

The Milwaukee MW12 Digital Phosphate Tester measures Phosphate levels from  0.00 to 2.50 ppm, with a resolution of 0.01 ppm.

Range  0.00 to 2.50 ppm
Resolution  0.01 ppm
Accuracy  ±0.04 ppm or ±4% of reading @ 25 °C
Typical EMC Dev  ±0.01 ppm
Light Source  Light Emitting Diode @ 525 nm
Light Detector  Silicon Photocell
Method  Adaptation of Standard Methods for examining Wastewater 20th Edition Ascorbic Acid Method. The reaction between Phosphate and the reagent causes a blue tint in the sample
Environment  0 to 50°C (32 to 122 °F) max. 95% RH non-condensing
Battery Type  1 x 1.5V AAA
Auto-shut off  After 2 minutes of non-use
Meter Dimensions  3.2 x 2.4 x 1.5 inches (81.30 x 61 x 38.1 mm)
Meter Weight  0.14 lbs. (0.18 kg)
Packaged Dimensions  4.53 x 4.53 x 3.31 inches (115 x 115 x 84 mm)
Packaged Weight  0.4 lbs, (0.18 kg)

Buy the Milwaukee MW12 Digital Phosphate Tester, an essential tool for monitoring phosphate levels in water. Its digital accuracy and user-friendly design deliver quick results for professionals in aquaculture, water treatment, and education, ensuring safe and high-quality water standards for environmental health and sustainability.

Additional information
Range, Resolution, Accuracy

Range: 0.00 to 2.50 ppm
Resolution: 0.01 ppm
Accuracy: ±0.04 ppm or ±4% of reading @ 25 °C

Light Source

Light Emitting Diode @ 525 nm

Light Detector

Silicon Photocell

Method

 Adaptation of Standard Methods for examining Wastewater 20th Edition Ascorbic Acid Method. The reaction between Phosphate and the reagent causes a blue tint in the sample

Typical EMC Dev

±0.01 ppm

Operating Environment

0 to 50°C (32 to 122 °F) max. 95% RH non-condensing

Power supply

1 x 1.5V AAA

Auto-off

After 2 minutes of non-use

Dimensions

Meter Dimensions: 3.2 x 2.4 x 1.5 inches (81.30 x 61 x 38.1 mm)
Packaged Dimensions: 4.53 x 4.53 x 3.31 inches (115 x 115 x 84 mm)

Weight

Meter Weight: 0.14 lbs. (0.18 kg)
Packaged Weight: 0.4 lbs, (0.18 kg)

Manual

Manual

Manual

Manual

Specifications

Specifications

Range  0.00 to 2.50 ppm
Resolution  0.01 ppm
Accuracy  ±0.04 ppm or ±4% of reading @ 25 °C
Typical EMC Dev  ±0.01 ppm
Light Source  Light Emitting Diode @ 525 nm
Light Detector  Silicon Photocell
Method  Adaptation of Standard Methods for the examination of wastewater 20 th edition Ascorbic Acid Method. The reaction between Phosphate and the reagent causes a blue tint in the sample
Environment  0 to 50°C (32 to 122 °F) max. 95% RH non-condensing
Battery Type  1 x 1.5V AAA
Auto-shut off  After 2 minutes of non-use
Meter Dimensions  3.2 x 2.4 x 1.5 inches (81.30 x 61 x 38.1 mm)
Meter Weight  0.14 lbs. (0.18 kg)
Packaged Dimensions  4.53 x 4.53 x 3.31 inches (115 x 115 x 84 mm)
Packaged Weight  0.4 lbs, (0.18 kg)