Milwaukee MW12 Digital Phosphate Tester
Short Description:
The Milwaukee MW12 Digital Phosphate Tester is an essential tool for monitoring phosphate levels in water. With its digital accuracy and user-friendly design, it provides quick results for aquaculture, water treatment, and education professionals, helping to maintain safe and high-quality water standards for environmental health and sustainability.
- Range: 0.00 to 2.50 ppm
- Resolution: 0.01 ppm
- Accuracy: ±0.04 ppm or 4% of reading @ 25 °C
Buy Milwaukee MW12
The Milwaukee MW12 Digital Phosphate Tester is a state-of-the-art tool designed to accurately measure phosphate levels in various water sources. This photometer is particularly beneficial for applications in aquaculture, water treatment, and educational settings, where precise monitoring of phosphate concentration is essential for maintaining water quality.
Advantages
The Milwaukee MW12 offers several key benefits that enhance its usability and effectiveness:
- Digital Precision: Unlike traditional testing methods, the MW12 provides a digital readout that ensures accurate measurements of phosphate levels, eliminating the ambiguity often associated with colorimetric tests.
- User-Friendly Interface: The device features a large LCD display that allows users to easily read results, making it accessible for both experienced professionals and those new to water quality testing.
- Rapid Results: Users can expect quick results by simply adding the appropriate reagent to their water sample. This efficiency is crucial in environments where timely monitoring is necessary.
- No Calibration Needed: The MW12 is designed for straightforward operation with no need for calibration, allowing users to focus on their testing without additional preparation.
Applications
The versatility of the Milwaukee MW12 makes it suitable for a wide range of applications:
- Aquaculture: Monitoring phosphate levels is vital for maintaining healthy aquatic environments in fish farming and aquaculture operations. The
MW12 enables producers to ensure optimal conditions for fish growth and health. - Water Treatment Facilities: Municipal and industrial water treatment plants utilize the MW12 to monitor phosphate concentrations, which can impact water quality and treatment efficacy.
- Educational Institutions: The MW12 serves as an excellent educational tool in laboratories and classrooms, helping students learn about water quality analysis and the significance of phosphate testing in real-world scenarios.
Milwaukee MW12 Specifications
The Milwaukee MW12 Digital Phosphate Tester measures Phosphate levels from 0.00 to 2.50 ppm, with a resolution of 0.01 ppm.
Range | 0.00 to 2.50 ppm |
Resolution | 0.01 ppm |
Accuracy | ±0.04 ppm or ±4% of reading @ 25 °C |
Typical EMC Dev | ±0.01 ppm |
Light Source | Light Emitting Diode @ 525 nm |
Light Detector | Silicon Photocell |
Method | Adaptation of Standard Methods for examining Wastewater 20th Edition Ascorbic Acid Method. The reaction between Phosphate and the reagent causes a blue tint in the sample |
Environment | 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing |
Battery Type | 1 x 1.5V AAA |
Auto-shut off | After 2 minutes of non-use |
Meter Dimensions | 3.2 x 2.4 x 1.5 inches (81.30 x 61 x 38.1 mm) |
Meter Weight | 0.14 lbs. (0.18 kg) |
Packaged Dimensions | 4.53 x 4.53 x 3.31 inches (115 x 115 x 84 mm) |
Packaged Weight | 0.4 lbs, (0.18 kg) |
Buy the Milwaukee MW12 Digital Phosphate Tester, an essential tool for monitoring phosphate levels in water. Its digital accuracy and user-friendly design deliver quick results for professionals in aquaculture, water treatment, and education, ensuring safe and high-quality water standards for environmental health and sustainability.
Range, Resolution, Accuracy |
Range: 0.00 to 2.50 ppm |
---|---|
Light Source |
Light Emitting Diode @ 525 nm |
Light Detector |
Silicon Photocell |
Method |
Adaptation of Standard Methods for examining Wastewater 20th Edition Ascorbic Acid Method. The reaction between Phosphate and the reagent causes a blue tint in the sample |
Typical EMC Dev |
±0.01 ppm |
Operating Environment |
0 to 50°C (32 to 122 °F) max. 95% RH non-condensing |
Power supply |
1 x 1.5V AAA |
Auto-off |
After 2 minutes of non-use |
Dimensions |
Meter Dimensions: 3.2 x 2.4 x 1.5 inches (81.30 x 61 x 38.1 mm) |
Weight |
Meter Weight: 0.14 lbs. (0.18 kg) |
Specifications
Range | 0.00 to 2.50 ppm |
Resolution | 0.01 ppm |
Accuracy | ±0.04 ppm or ±4% of reading @ 25 °C |
Typical EMC Dev | ±0.01 ppm |
Light Source | Light Emitting Diode @ 525 nm |
Light Detector | Silicon Photocell |
Method | Adaptation of Standard Methods for the examination of wastewater 20 th edition Ascorbic Acid Method. The reaction between Phosphate and the reagent causes a blue tint in the sample |
Environment | 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing |
Battery Type | 1 x 1.5V AAA |
Auto-shut off | After 2 minutes of non-use |
Meter Dimensions | 3.2 x 2.4 x 1.5 inches (81.30 x 61 x 38.1 mm) |
Meter Weight | 0.14 lbs. (0.18 kg) |
Packaged Dimensions | 4.53 x 4.53 x 3.31 inches (115 x 115 x 84 mm) |