Milwaukee MW306 MAX EC/TDS/NaCl/Temp Logging Portable Meter
The Milwaukee MW306 MAX EC/TDS/NaCl/Temp Logging Portable Meter is a durable, accurate, and user-friendly tool essential for professionals in various industries. With features like data logging and automatic temperature compensation, it provides reliable and precise measurements, making it ideal for agriculture, laboratory research, and water quality assessment.
- Range TDS: 0.00 to 14.99 ppm (mg/L) | 15.0 to 149.9 ppm (mg/L) | 150 to 1499 ppm mg/L | 1.50 to 14.99 g/L | 15.0 to 100.0 g/L | up to 400.0 g/L (absolute TDS* with 0.80 factor)
- Range SALINITY: 0.0 to 400.0 % Nacl | 2.00 to 42.00 PSU | 0.00 to 80.00 g/L
- RANGE TEMPERATURE: -20.0 to 120.0°C | -4.0 to 248.0°F
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Buy Milwaukee MW306 MAX
The Milwaukee MW306 MAX EC/TDS/NaCl/Temp Logging Portable Meter is a versatile instrument designed for accurate measurement in various applications. This portable meter stands out due to its ability to measure four critical parameters: Electrical Conductivity (EC), Total Dissolved Solids (TDS), salinity (NaCl), and temperature. Its robust design and user-friendly interface make it a preferred choice for professionals in fields such as hydroponics, horticulture, laboratories, and water treatment.
Key Features
The Milwaukee MW306 MAX offers several features that enhance its usability and functionality:
- Waterproof Design: The meter’s IP67 rating makes it waterproof and able to withstand harsh environmental conditions, making it suitable for both laboratory and field use.
- Data Logging Capabilities: Users can store up to 1,000 logs, including readings and GLP data. This feature facilitates easy tracking of measurements over time.
- Multiple Logging Methods: The device supports various logging methods, including manual log-on-demand, manual log-on-stability, and interval logging, which allows for flexible data collection tailored to specific needs.
- Automatic Temperature Compensation: The built-in temperature sensor automatically adjusts readings based on temperature fluctuations, ensuring high accuracy.
Applications
The Milwaukee MW306 MAX is ideal for a wide range of applications:
- Hydroponics: Essential for monitoring nutrient levels in water solutions.
- Horticulture: Helps assess soil quality and water conditions for optimal plant growth.
- Laboratories: Provides precise measurements required for scientific research and experiments.
- Food Processing: Ensures compliance with safety standards by monitoring water quality used in food production.
- Water Treatment: Assists in evaluating the effectiveness of water purification processes.
Ease of Use
One of the standout aspects of the Milwaukee MW306 MAX is its user-friendly interface. The large dual-level digital LCD display provides clear readings, making it easy to interpret results quickly. Additionally, the meter’s lightweight design enhances portability, allowing users to conduct tests conveniently in various locations.
Milwaukee MW306 MAX Specifications
The Milwaukee MW306 MAX measures TDS in a range from 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, and up to 400.0 g/L.
| EC Range | 0.00 to 29.99 uS/cm / 3.0 to 29.9 uS/cm |
| EC Range | 30.0 to 299.9 uS/cm / 300 to 2999 uS/cm |
| EC Range | 3.00 to 29.99 mS/cm / 30.0 to 200.0 mS/cm / up to 500.0 mS/cm, absolute conductivity* |
| TDS Range | 0.00 to 14.99 ppm (mg/L) |
| TDS Range | 15.0 to 149.9 ppm (mg/L) / 150 to 1499 ppm (mg/L) |
| TDS Range | 1.50 to 14.99 g/L / 15.0 to 100.0 g/l / up to 400.0 g/L absolute TDS* (with 0.80 factor) |
| Salinity Range | 0.0 to 400.0 %NaCl / 2.00 to 42.00 PSU |
| Salinity Range | 0.00 to 80.00 g/L |
| Temp. Range | -20.0 to 120.00°C (-4.0 to 248.0°F) |
| EC Resolution | 0.01 uS/cm / 0.1 uS/cm / 1 uS/cm |
| EC Resolution | 0.01 mS/cm / 0.1 mS/cm |
| TDS Resolution | 0.01 ppm / 0.1 ppm / 1 ppm |
| TDS Resolution | 0.01 g/L / 0.1 g/L |
| Salinity Resolution | 0.1 % NaCl / 0.01 PSU / 0.01 g/L |
| Temperature Resolution | 0.1°C / 0.1°F |
| Accuracy | @ 25°C / 77°F |
| EC | ± 1% of reading / ±0.05 uS/cm or 1 digit, whichever is greater |
| TDS | ±1 % of reading / ±0.03 ppm or 1 digit, whichever is greater |
| Salinity | ±1 % of reading |
| Temperature | ±0.5°C (±0.9°F) |
| EC/TDS | single cell factor calibration, 6 standards 84 uS/cm, 1413 uS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm / one point offset 0.00 uS/cm |
| Salinity Calibration | one point with MA9066 salinity calibration solution |
| Temperature Calibration | no temperature calibration |
| Temperature Compensation | Automatic, -5.0 to 100.0°C (-23.0 to 212.0°F) or manual from -20 to 120°C (-4.0 to 248.0°F) or NO TC without temperature compensation |
| Conductivity temperature coefficient | 0.00 to 6.00 % / °C (EC and TDS only) | Default value 1.90 % / °C |
| TDS factor | 0.40 to 0.80 / Default value 0.5 |
| EC Probe | MA815D/1, (4 ring) |
| Temperature probe | Built-in temperature sensor |
| Logging | Maximum 1,000 samples (max. 100 lots) / on demand, 200 samples; on stability, 200 samples / interval logging, 1000 |
| PC Connectivity | 1 micro USB port |
| Battery type | 3 X 1.5V alkaline AA (included) |
| Battery life | Approx. 200 hours of use |
| Auto-off | Selectable 5, 10, 30, 60 min. or off |
| Environment | 0 to 50°C / 32 to 122°F; max RH 95% |
| Dimensions | 200 x 85 x 50 mm (7.9 x 3.3 x 2.0 inches) |
| Casing | IP67 |
| Weight | .26 kg / 0.58 lbs (with battery) |
Buy the Milwaukee MW306 MAX EC/TDS/NaCl/Temp Logging Portable Meter for a durable, accurate, and user-friendly solution that professionals in various industries rely on. Its features, including data logging and automatic temperature compensation, ensure reliable and precise measurements suitable for agriculture, laboratory research, and water quality assessment.
Specifications
| EC Range | 0.00 to 29.99 uS/cm / 3.0 to 29.9 uS/cm |
| EC Range | 30.0 to 299.9 uS/cm / 300 to 2999 uS/cm |
| EC Range | 3.00 to 29.99 mS/cm / 30.0 to 200.0 mS/cm / up to 500.0 mS/cm, absolute conductivity* |
| TDS Range | 0.00 to 14.99 ppm (mg/L) |
| TDS Range | 15.0 to 149.9 ppm (mg/L) / 150 to 1499 ppm (mg/L) |
| TDS Range | 1.50 to 14.99 g/L / 15.0 to 100.0 g/l / up to 400.0 g/L absolute TDS* (with 0.80 factor) |
| Salinity Range | 0.0 to 400.0 %NaCl / 2.00 to 42.00 PSU |
| Salinity Range | 0.00 to 80.00 g/L |
| Temp. Range | -20.0 to 120.00°C (-4.0 to 248.0°F) |
| EC Resolution | 0.01 uS/cm / 0.1 uS/cm / 1 uS/cm |
| EC Resolution | 0.01 mS/cm / 0.1 mS/cm |
| TDS Resolution | 0.01 ppm / 0.1 ppm / 1 ppm |
| TDS Resolution | 0.01 g/L / 0.1 g/L |
| Salinity Resolution | 0.1 % NaCl / 0.01 PSU / 0.01 g/L |
| Temperature Resolution | 0.1°C / 0.1°F |
| Accuracy | @ 25°C / 77°F |
| EC | ± 1% of reading / ±0.05 uS/cm or 1 digit, whichever is greater |
| TDS | ±1 % of reading / ±0.03 ppm or 1 digit, whichever is greater |
| Salinity | ±1 % of reading |
| Temperature | ±0.5°C (±0.9°F) |
| EC/TDS | single cell factor calibration, 6 standards 84 uS/cm, 1413 uS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm / one point offset 0.00 uS/cm |
| Salinity Calibration | one point with MA9066 salinity calibration solution |
| Temperature Calibration | no temperature calibration |
| Temperature Compensation | Automatic, -5.0 to 100.0°C (-23.0 to 212.0°F) or manual from -20 to 120°C (-4.0 to 248.0°F) or NO TC without temperature compensation |
| Conductivity temperature coefficient | 0.00 to 6.00 % / °C (EC and TDS only) | Default value 1.90 % / °C |
| TDS factor | 0.40 to 0.80 / Default value 0.5 |
| EC Probe | MA815D/1, (4 ring) |
| Temperature probe | Built-in temperature sensor |
| Logging | Maximum 1,000 samples (max. 100 lots) / on demand, 200 samples; on stability, 200 samples / interval logging, 1000 |
| PC Connectivity | 1 micro USB port |
| Battery type | 3 X 1.5V alkaline AA (included) |
| Battery life | Approx. 200 hours of use |
| Auto-off | Selectable 5, 10, 30, 60 min. or off |
| Environment | 0 to 50°C / 32 to 122°F; max RH 95% |
| Dimensions | 200 x 85 x 50 mm (7.9 x 3.3 x 2.0 inches) |
| Casing | IP67 |
| Weight | .26 kg / 0.58 lbs (with battery) |

Bench Multimeters