Milwaukee MW806 4-in-1 pH/EC/TDS/Temp. Combo Meter with ATC

(No Reviews)

The Milwaukee MW806 MAX 4-in-1 combo meter is a durable tool for professionals needing accurate pH, EC, TDS, and temperature measurements. Its integrated design and user-friendly interface enhance productivity in industries like agriculture and laboratory research by consolidating multiple measurements into one device.

 

Terms of sending goods ›
  • In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
  • For out-of-stock items, delivery may take 2 to 4 business weeks.
SKU: 101263 Category:
Brand:Milwaukee

Show Price on WhatsApp

In stockDelivers in 2-3 business days.
Description

Buy Milwaukee MW806

The Milwaukee MW806 MAX is a versatile 4-in-1 combo meter designed for precise measurement of pH, electrical conductivity (EC), total dissolved solids (TDS), and temperature. This all-in-one device streamlines water quality testing across various applications, including agriculture, hydroponics, and laboratory research.

Key Features

The Milwaukee MW806 MAX offers several notable features that enhance its functionality and user experience:

  • Integrated Measurements: With a single probe, users can simultaneously measure pH, EC, TDS, and temperature, eliminating the need for multiple instruments.
  • Automatic Temperature Compensation (ATC): This feature ensures accurate readings by adjusting measurements based on temperature variations, which is crucial for environments with fluctuating temperatures.
  • User-Friendly Design: The device boasts a large, easy-to-read display with adjustable contrast, facilitating clear data visualization even in low-light conditions. Its lightweight and portable form factor, weighing approximately 260 grams, makes it convenient for field use.
  • Data Logging and Connectivity: Equipped with a USB connection and data logger function, the MW806 MAX allows users to store up to 1,000 log records, which can be exported to a PC for further analysis.

Replaceable Probe: The included MA852D/1 amplified combination probe is replaceable, extending the device’s lifespan and ensuring sustained measurement accuracy.

Applications

The Milwaukee MW806 MAX is particularly beneficial in the following scenarios:

  • Agriculture and Hydroponics: Maintaining optimal pH and nutrient levels is vital for plant health. This meter assists growers in monitoring and adjusting these parameters to enhance crop yield and quality.
  • Water Treatment: Ensuring water quality in treatment facilities requires monitoring of precise pH, conductivity, and TDS levels. The MW806 MAX provides reliable measurements to support effective water treatment processes.
  • Laboratory Research: Researchers conducting experiments involving aqueous solutions can utilize this device to accurately and efficiently measure multiple parameters, streamlining data collection.

Milwaukee MW806 Specifications

The Milwaukee MW806 MAX can measure pH from -2.00 to 20.00, EC from 0.00 to 20.00 mS/cm, TDS from 0.00 to 10.00 ppt (g/L), and temperature from -20.0 to 120.0°C (-4.0 to 248°F).

pH Range  -2.00 to 20.00 pH
EC Range  0.00 to 20.00 mS/cm
TDS Range  0.00 to 10.00 ppt (g/L)
Temperature Range  -20.0 to 120.0°C / -4.0 to 248°F
pH Resolution  0.01 pH
EC Resolution  0.01 mS/cm
TDS Resolution  0.01 ppt (g/L)
Temperature Resolution  0.1°C / 0.1°F
pH Accuracy  ±0.01
EC/TDS Accuracy  ±2% Full Scale
Temperature accuracy  ±0.5°C / ±0.9°F
Calibration pH  Automatic up to 5 – point pH, 7 Standard Calibration Buffers pH1.68; 4.01; 6.86; 7.01; 9.18, 10.01; 12.45 and 2 Custom Buffers
Calibration EC/TDS  Single Cell Factor Calibration; 3 Standards 1413 μS/cm; 5.00 mS/cm; 12.88 mS/cm / One- point Offset 0.00 mS/cm
Temperature Calibration  Factory Calibrated
Temperature Compensation  Automatic (ATC) from -20 to 120°C (-4 to 248°F) | Manual (MTC) from -20 to 120°C (-4 to 248°F)
Conductivity temperature coefficient  0.00 to 6.00 % /ºC (EC & TDS only) | Default value 1.9 %/ºC
TDS Factor  0.40 to 0.80; default value 0.5
Logging Memory  Up to 1,000 log records (stored in up to 100 lots) | On demand, up to 200 logs | on Stability, up to 200 logs | Interval logging, up to 1,000 logs | Parameter-Specific log storage location
PC connectivity  1 micro USB port
Battery Type  3 X 1.5V Alkaline AA batteries (included) | Approximately 200 hours of use
Environment  0 to 50°C / 32 to 122°F; max RH 95%
Dimensions Meter  7.9 x 3.3 x 2 inches (200 x 85 x 50 mm)
Auto-off  After 10 minutes of non-use
Casing  IP67 protection level
Weight Meter  260 g (0.57 lb)
Dimensions Packaging  12 x 11 x 4.5 inches (305 x 280 x 115 mm)
Weight Packaged  3.2 lbs. (1.44 kg)
Probe Specifications  MA852D/1 Amplified pH/EC/TDS/Temp Probe (included)
Range  pH 0 to 13 | Temperature 0.0 to 60.0°C (32.0 to 140.0°F)
EC electrodes  2 X graphite
Reference  Single, Ag/AgCl
Junction  Cloth
Electrolyte (pH)  Gel
Body  ABS
Connection  DIN
Cable  1 m (3.3′)

Buy the Milwaukee MW806 MAX 4-in-1 pH/EC/TDS/Temp combo meter, a durable tool that accurately measures pH, EC, TDS, and temperature. Its integrated design and user-friendly interface streamline workflows and boost productivity across agriculture and laboratory research industries.

Manual

Manual

Manual

Manual

Specifications

Specifications

pH Range  -2.00 to 20.00 pH
EC Range  0.00 to 20.00 mS/cm
TDS Range  0.00 to 10.00 ppt (g/L)
Temperature Range  -20.0 to 120.0°C / -4.0 to 248°F
pH Resolution  0.01 pH
EC Resolution  0.01 mS/cm
TDS Resolution  0.01 ppt (g/L)
Temperature Resolution  0.1°C / 0.1°F
pH Accuracy  ±0.01
EC/TDS Accuracy  ±2% Full Scale
Temperature accuracy  ±0.5°C / ±0.9°F
Calibration pH  Automatic up to 5 – point pH, 7 Standard Calibration Buffers pH1.68; 4.01; 6.86; 7.01; 9.18, 10.01; 12.45 and 2 Custom Buffers
Calibration EC/TDS  Single Cell Factor Calibration; 3 Standards 1413 μS/cm; 5.00 mS/cm; 12.88 mS/cm / One- point Offset 0.00 mS/cm
Temperature Calibration  Factory Calibrated
Temperature Compensation  Automatic (ATC) from -20 to 120°C (-4 to 248°F) | Manual (MTC) from -20 to 120°C (-4 to 248°F)
Conductivity temperature coefficient  0.00 to 6.00 % /ºC (EC & TDS only) | Default value 1.9 %/ºC
TDS Factor  0.40 to 0.80; default value 0.5
Logging Memory  Up to 1,000 log records (stored in up to 100 lots) | On demand, up to 200 logs | on Stability, up to 200 logs | Interval logging, up to 1,000 logs | Parameter-Specific log storage location
PC connectivity  1 micro USB port
Battery Type  3 X 1.5V Alkaline AA batteries (included) | Approximately 200 hours of use
Environment  0 to 50°C / 32 to 122°F; max RH 95%
Dimensions Meter  7.9 x 3.3 x 2 inches (200 x 85 x 50 mm)
Auto-off  After 10 minutes of non-use
Casing  IP67 protection level
Weight Meter  260 g (0.57 lb)
Dimensions Packaging  12 x 11 x 4.5 inches (305 x 280 x 115 mm)
Weight Packaged  3.2 lbs. (1.44 kg)
Probe Specifications  MA852D/1 Amplified pH/EC/TDS/Temp Probe (included)
Range  pH 0 to 13 | Temperature 0.0 to 60.0°C (32.0 to 140.0°F)
EC electrodes  2 X graphite
Reference  Single, Ag/AgCl
Junction  Cloth
Electrolyte (pH)  Gel
Body  ABS
Connection  DIN
Cable  1 m (3.3′)

Recently viewed Products