PCE-DM 7 True-RMS Digital Multimeter – 9999 Counts, 5 MHz Frequency, NCV
The PCE-DM 7 packs True-RMS accuracy and 9999-count resolution into a compact body with a bright 2.8″ LCD. Measure up to 1000 V DC / 750 V AC, 9.999 A AC/DC, capacitance to 9.999 mF, resistance to 99.99 MΩ, frequency to 5 MHz, plus K-type temperature. Safety: CAT II 1000 V / CAT III 600 V.
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Order Via Online Form
PCE-DM 7 Digital Multimeter
The PCE-DM 7 Digital Multimeter is a versatile measuring instrument designed for both professionals and hobbyists. Known for its reliability, it excels in providing accurate measurements across a variety of electrical parameters, making it an essential tool in fields such as electronics, electrical engineering, and maintenance.
PCE-DM 7 Key Features
The PCE-DM 7 Digital Multimeter is equipped with several key features such as automatic and manual measurement range selection that enhance its functionality and usability in various measurement tasks:
- True RMS Measurement: This feature allows for accurate measurements of AC voltage and current, particularly in non-sinusoidal waveforms, ensuring reliable readings in complex electrical systems.
- Temperature Measurement: The multimeter can measure temperature using a thermocouple, expanding its utility for applications that require thermal assessments.
- Automatic and Manual Range Selection: Users can choose between automatic range selection for ease of use or manual selection for more control over measurements, catering to different preferences and scenarios.
- Dual Display: The device features a 2.8-inch LCD with a backlight, providing both numerical readings and a bar graph display for quick visual assessments of measurements.
- Non-Contact Voltage Detection (NCV): This safety feature allows users to detect the presence of voltage without direct contact, enhancing user safety during electrical testing.
- Hold Function: This function enables users to save and freeze measurement results on the display, facilitating easier reading and recording of data.
- Automatic Power-Off: To conserve battery life, the multimeter automatically shuts off after five minutes of inactivity, making it energy-efficient.
What’s in the PCE-DM 7 Box

DM7 meter, K-type temperature sensor, test leads, 2× AA batteries, user manual, soft storage bag.
Is the PCE-DM 7 a True-RMS multimeter?
Yes—DM7 provides True-RMS measurement for accurate AC readings on non-linear loads.
What measurement ranges does it support?
Up to 1000 V DC, 750 V AC, 9.999 A AC/DC, resistance to 99.99 MΩ, capacitance to 9.999 mF, and frequency up to 5 MHz.
Does it include non-contact voltage detection (NCV)
Yes—NCV is built in for quick, contact-free live-wire checks
Does it measure temperature?
Yes—K-type thermocouple input, typically −20 °C to +1000 °C
Who is the DM7 best for
Technicians, electricians, and maintenance teams needing a compact True-RMS meter with 9999 counts, 5 MHz frequency, and NCV safety.
| max___voltage____dc (multimeter) |
751 – 1000V DC |
|---|---|
| max___voltage____ac (multimeter) |
501 – 750V AC |
| auto___range (multimeter) |
Yes |
| true___rms (multimeter) |
No |
| max___current___dc (multimeter) |
0 to 10A |
| max___current___ac (multimeter) |
0 to 10A |
specifications
PCE-DM 7 True-RMS Digital Multimeter specifications
| Direct voltage DC | |
| Measurement range up to | 0 … 9,999 mV |
| Resolution | 0,001 mV |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 10 … 99,99 mV |
| Resolution | 0,01 mV |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 100 … 999,9 mV |
| Resolution | 0,1 mV |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 1 … 9,999 V |
| Resolution | 0,001 V |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 10 … 99,99 V |
| Resolution | 0,01 V |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct voltage DC | |
| Measurement range up to | 100 … 999,9 V |
| Resolution | 0,1 V |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 0 … 9999 µA |
| Resolution | 1 µA |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 10 … 99,99 mA |
| Resolution | 0,01 mA |
| Accuracy | ±(0.8 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 100 … 999,9 mA |
| Resolution | 0,1 mA |
| Accuracy | ±(1 % of Rd +3 digits) |
| Direct current DC | |
| Measurement range up to | 1 … 9,999 A |
| Resolution | 0,001 A |
| Accuracy | ±(1 % of Rd +3 digits) |
| Capacity | |
| Measurement range up to | 0 … 9,999 nF |
| Resolution | 0,001 nF |
| Accuracy | ±(5.0 % of Rd +20 digits) |
| Capacity | |
| Measurement range up to | 10 … 99,99 nF |
| Resolution | 0,01 nF |
| Accuracy | ±(2.0 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 100 … 999,9 nF |
| Resolution | 0,1 nF |
| Accuracy | ±(2.0 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 1 … 9,999 µF |
| Resolution | 0,001 µF |
| Accuracy | ±(2.0 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 10 … 99,99 µF |
| Resolution | 0,01 µF |
| Accuracy | ±(2.0 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 100 … 999,9 µF |
| Resolution | 0,1 µF |
| Accuracy | ±(2.0 % of Rd +5 digits) |
| Capacity | |
| Measurement range up to | 1 … 9,999 mF |
| Resolution | 0,001 mF |
| Accuracy | ±(5.0 % of Rd +5 digits) |
| AC voltage | |
| Measurement range up to | 0 … 9,999 mV |
| Resolution | 0,001 mV |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 10 … 99,99 mV |
| Resolution | 0,01 mV |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 100 … 999,9 mV |
| Resolution | 0,1 mV |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 1 … 9,999 V |
| Resolution | 0,001 V |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 10 … 99,99 V |
| Resolution | 0,01 V |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| AC voltage | |
| Measurement range up to | 100 … 750 V |
| Resolution | 0,1 V |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 0 … 9999 µA |
| Resolution | 1 µA |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 10 … 99,99 mA |
| Resolution | 0,01 mA |
| Accuracy | ±(1 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 100 … 999,9 mA |
| Resolution | 0,1 mA |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Alternating current AC | |
| Measurement range up to | 1 … 9,999 A |
| Resolution | 0,001 A |
| Accuracy | ±(1.2 % of Rd +3 digits) |
| Frequency range | 40 … 1000 Hz |
| Resistance | |
| Measurement range up to | 0 … 99,99 Ω |
| Resolution | 0,01 Ω |
| Accuracy | ±(1 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 100 … 999,9 Ω |
| Resolution | 0,1 Ω |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 1 … 9,999 kΩ |
| Resolution | 0,001 kΩ |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 10 … 99,99 kΩ |
| Resolution | 0,01 kΩ |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 100 … 999,9 kΩ |
| Resolution | 0,1 kΩ |
| Accuracy | ±(0.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 1 … 9,999 M Ω |
| Resolution | 0,001 M Ω |
| Accuracy | ±(1.5 % of Rd +3 digits) |
| Resistance | |
| Measurement range up to | 10 … 99,99 M Ω |
| Resolution | 0,01 M Ω |
| Accuracy | ±(3.0 % of Rd +5 digits) |
| Duty cycle | |
| Measurement range up to | 1 … 99 % |
| Resolution | 0,1 % |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 0 … 99,99 Hz |
| Resolution | 0,01 Hz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 100 … 999,9 Hz |
| Resolution | 0,1 Hz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 1 … 9,999 kHz |
| Resolution | 0,001 kHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 10 … 99,99 kHz |
| Resolution | 0,01 kHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 100 … 999,9 kHz |
| Resolution | 0,1 kHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Frequency | |
| Measurement range up to | 1 … 5 MHz |
| Resolution | 0,001 MHz |
| Accuracy | ±(0.1 % of Rd +2 digits) |
| Temperature | |
| Measurement range up to | -20 … +1000 °C |
| Resolution | 1 °C |
| Accuracy | ±(2.5 % of Rd +5 digits) |
| Temperature | |
| Measurement range up to | -4 … +1832 °F |
| Resolution | 1 °F |
| Accuracy | ±(2.5 % of Rd +5 digits) |
| General technical data | |
| Measuring functions | HOLD |
| Display type | LCD with backlight |
| Display size | 2,8 Inch |
| Measuring rate | 3 x per second |
| Automatic power-off | 5 min |
| Safety standard | CAT II 1000 V, CAT III 600 V |
| Measurement range selection | Automatic, Manual |
| Menu language | English, English (GB) |
| Protection class (device) | IP20 |
| Weight | 175 g |
| Operating conditions | 0 … 40 °C , 0 … 75 % RH |
| Storage conditions | -20 … 60 °C , 0 … 80 % RH |
| (Rechargeable) battery | 2 x 1,5 V AA battery , Alkali-manganese |
| Capacity | 3000 mAh |
| Dimensions ( L x W x H ) | 140 x 70 x 35 mm |

Bench Multimeters