Tektronix RSA607A Spectrum Analyzer
(No Reviews)
Looking to buy the Tektronix RSA607A? Find competitive prices in Dubai, UAE! Upgrade your lab equipment with this high-performance oscilloscope today.
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
In stockDelivers in 2-3 business days.
Description
Introduction of Tektronix RSA607A
The Tektronix RSA607A instruments require a PC running Windows 7, Windows 8/8.1, or Windows 10 with a 64-bit operating system and a USB 3.0 connection. A minimum of 8 GB RAM and 20 GB of free disk space is necessary for installing SignalVu-PC. To achieve full real-time performance with the RSA600, an Intel Core i7 4th generation processor is recommended. Lower-performance processors can be used but will result in reduced real-time capabilities. Additionally, the PC must have a storage drive capable of streaming data at a rate of 300 MB/sec for recording purposes.
Tektronix RSA607A Key Features
- 9 kHz to 3.0/7.5 GHz frequency range covers a broad range of analysis needs
- 40 MHz acquisition bandwidth enables real time analysis for transient capture and vector analysis
- Amplitude accuracy of 0.2 dB to 3 GHz (95% confidence)
- High speed full-span sweeps (25.0 GHz/sec) for fast setup and discovery
- Standard GPS/GLONASS/Beidou receiver
- Optional tracking generator for gain/loss, antenna and cable measurements
- DataVu-PC software enables multi-unit recording in variable bandwidths
- SignalVu-PC software offers real time signal processing with DPX® Spectrum/Spectrogram to minimize time spent finding transient problems.
specifications
specifications
Tektronix RSA607A Specifications
| Specification | Details |
| Frequency Range | 9 kHz to 7.5 GHz |
| Acquisition Bandwidth | 40 MHz |
| Dynamic Range | 70 dB |
| Amplitude Accuracy | ±1.5 dB (3 GHz to 7.5 GHz) |
| Full-span Sweep Speed | 25.0 GHz/sec |
| Input Impedance | 50 Ω |
| Maximum RF Input Level | +33 dBm (10 MHz to 7.5 GHz, RF Attn ≥ 20 dB) |
| Reference Frequency Accuracy | ±1 x 10⁻⁶ (Initial), ±1 x 10⁻⁶ (1 year aging) |
| Phase Noise | -94 dBc/Hz (10 kHz offset, typical at 1 GHz CF) |
| Preamp Gain | 21 dB at 6 GHz |
| Displayed Average Noise Level (DANL) | -155 dBm/Hz to -145 dBm/Hz depending on frequency range and preamp setting |
| Spurious Response | < -100 dBm (80 MHz to 7.5 GHz) |
| External Reference Input | BNC connector, 50 Ω, 1 to 20 MHz |
| Trigger Input | BNC, Voltage Range: TTL, 0.0 V to 5.0 V |
| Power Consumption | 45 W maximum |
| Operating Temperature Range | -10 °C to +55 °C |
| Dimensions (HxWxD) | 75.0 mm x 222.3 mm x 358.6 mm |
| Weight | 2.79 kg (6.15 pounds) |