Fluke 124B/EU/S Industrial ScopeMeter + SCC 40MHz
- True-rms measurements across V, A, and frequency
- 750V DC voltage rating with ±(0.5%+5 counts) accuracy
- 70MHz frequency range with 1Hz resolution
- Current clamp input with 40MHz bandwidth via SCC
- Peak detection modes (max/min/pk-to-pk)
- Temperature, dB, and phase measurement capabilities
- Durable design for industrial field use
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 124B/EU/S Industrial ScopeMeter is a versatile handheld oscilloscope designed for field service technicians and engineers who need to troubleshoot complex electrical systems. Combining the functionality of a digital multimeter with the visualization capabilities of a 70MHz bandwidth oscilloscope, this instrument excels at capturing transient events, analyzing waveform distortion, and verifying power quality in industrial environments. The included SCC current clamp extends measurement capabilities to amperage, making it an all-in-one solution for maintenance professionals who previously needed multiple devices to diagnose electrical faults.
Fluke 124B/EU/S Key Features
This ScopeMeter delivers True-rms accuracy across AC and DC voltage ranges from 500mV to 750V, with specifications including ±(0.5%+5 counts) DC accuracy and AC accuracy of ±(1%+10 counts) from 1Hz to 60Hz. The 70MHz frequency range with 1Hz resolution enables detailed analysis of high-frequency switching noise and power electronics. Peak detection modes (max, min, and pk-to-pk) with ranges up to 2200V capture transient voltage spikes that standard meters miss. The SCC 40MHz current clamp provides scale factors from 0.1mV/A to 10mV/mA, allowing accurate current measurements without breaking circuits. Additional capabilities include temperature measurement with optional probes, dB scaling for gain calculations, and phase analysis between voltage and current signals.
- DC voltage ranges: 500mV, 5V, 50V, 500V, 750V
- DC accuracy: ±(0.5%+5 counts)
- AC+DC accuracy: DC to 60Hz ±(1%+10 counts)
- Frequency range: 1Hz to 70MHz
- Current clamp: SCC 40MHz with 7 scale factors
- Peak detection: Max/min/pk-to-pk up to 2200V
- Display: 5000 counts full scale
Who Needs the Fluke 124B/EU/S?
Field service technicians rely on the Fluke 124B/EU/S when diagnosing intermittent faults on variable frequency drives, motor controls, and power supplies where standard handheld multimeters fall short. The 70MHz bandwidth captures the high-frequency harmonics that cause nuisance tripping and equipment overheating, while the True-rms measurement ensures accurate power calculations for non-linear loads. Maintenance engineers appreciate the all-in-one capability that eliminates the need to carry separate oscilloscopes, clamp meters, and power quality analyzers when responding to service calls.
Electrical contractors and panel builders find the ScopeMeter invaluable for commissioning new installations, verifying correct wiring, and troubleshooting control circuits. The phase measurement feature between voltage and current inputs is essential for power factor analysis and three-phase system verification. Buyers responsible for fleet maintenance or facility management equipment specify the Fluke 124B/EU/S because of its durability, long battery life, and the Fluke brand reputation for reliability in harsh industrial conditions.
The included SCC current clamp makes this particularly valuable for HVAC technicians measuring compressor currents, industrial electricians checking motor loads, and renewable energy installers verifying inverter output. No need to clamp separate probes around conductors—the integrated clamp design means faster setup times and more accurate phase relationship measurements between voltage and current.
Fluke 124B/EU/S Applications
Variable frequency drive (VFD) troubleshooting represents the primary application for the Fluke 124B/EU/S. The 70MHz bandwidth and True-rms accuracy reveal switching frequency harmonics, voltage notching, and common mode noise that damage sensitive electronics and cause motor overheating. Panel builders use the ScopeMeter during initial commissioning to verify that VFD installations meet harmonic distortion limits and that motor windings receive clean, stable power.
Power quality analysis becomes straightforward with the dB, phase, and frequency measurement capabilities. Facilities managers can document harmonic levels, identify resonance conditions, and verify that capacitor banks operate within safe limits. The temperature measurement function with optional probe makes the ScopeMeter useful for troubleshooting overheating connections, where increased resistance at loose terminals creates thermal signatures that correlate with voltage drop measurements.
The SCC current clamp function excels in applications ranging from measuring starting currents of large motors to verifying solar inverter output currents. The 40MHz bandwidth of the SCC clamp ensures accurate measurements even at high switching frequencies, while the multiple scale factors (0.1mV/A to 10mV/mA) provide flexibility from milliampere control circuits to hundreds of amps industrial loads.
Why Buy Fluke 124B/EU/S from Mohammad Mahdi Electronics?
Mohammad Mahdi Electronics supplies genuine Fluke test and measurement equipment with full manufacturer warranty and calibration certificates. Every Fluke 124B/EU/S ScopeMeter ships with the SCC current clamp, test leads, and protective holster ready for immediate field use. Our technical support team understands the specific measurement challenges faced by UAE industrial clients and can assist with probe selection, measurement technique, and interpretation of complex waveform data.
When you order from Mohammad Mahdi Electronics, you receive authentic Fluke products with the serial number registration that enables factory warranty service. We maintain stock of Fluke ScopeMeter models including the 124B/EU/S EU version with the correct power cord and regulatory compliance for European markets. Our efficient shipping ensures your measurement tools arrive when you need them, backed by the Mohammad Mahdi Electronics satisfaction guarantee.
For immediate availability and genuine Fluke warranty, contact Mohammad Mahdi Electronics today. Our team is ready to help you select the right measurement solution for your specific application requirements.
Fluke 124B/EU/S Specifications
| Input A and input B | ||
| DC voltage (VDC) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy | ±(0.5% +5 counts) | |
| Common mode rejection (CMRR) | >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz | |
| Full scale reading | 5000 counts | |
| True-rms voltages (V ac and V ac+dc) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V ac+dc) | ±(1% +10 counts) |
| 1 Hz to 60 Hz (V ac) | ±(1% +10 counts) | |
| Accuracy for 5% to 100% of range (AC or dc coupled) | 60 Hz to 20 kHz | ±(2.5% +15 counts) |
| DC rejection (only VAC) | >50 dB | |
| Common mode rejection (CMRR) | >100 dB @ dc | |
| >60 dB @ 50, 60, or 400 Hz | ||
| Full scale reading | 5000 counts, reading is independent of any signal crest factor. | |
| Peak | ||
| Modes | Max peak, Min peak, or pk-to-pk | |
| Ranges | 500 mV, 5 V, 50 V, 500 V, 2200 V | |
| Accuracy | Accuracy Max peak or Min peak | 5% of full scale |
| Accuracy Peak-to-Peak | 10% of full scale | |
| Full scale reading | 500 counts | |
| Frequency (Hz) | ||
| Ranges | 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz | |
| 124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz | ||
| Frequency range | 15 Hz (1 Hz) to 50 MHz in continuous autoset | |
| Accuracy @1 Hz to 1 MHz | ±(0.5% +2 counts) | |
| Full scale reading | 10,000 counts | |
| RPM | ||
| Max reading | 50.00 kRPM | |
| Accuracy | ±(0.5% +2 counts) | |
| Duty cycle (PULSE) | ||
| Range | 2% to 98% | |
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Pulse width (PULSE) | ||
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Full scale reading | 1000 counts | |
| Amperes (AMP) | ||
| With current clamp | Ranges | Same as V dc, V ac, V ac+dc, or PEAK |
| Scale factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA | |
| Accuracy | Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty) | |
| Temperature (TEMP) with optional temperature probe | ||
| Range | 200 °C/div (200 °F/div) | |
| Scale factor | 1 mV/°C and 1 mV/°F | |
| Accuracy | As V dc (add temp. probe uncertainty) | |
| Decibel (dB) | ||
| 0 dBV | 1 V | |
| 0 dBm (600 Ω /50 Ω) | 1 mW referenced to 600 Ω or 50 Ω | |
| dB on | V dc, V ac, or Vac+dc | |
| Full scale reading | 1000 counts | |
| Crest factor (CREST) | ||
| Range | 1 to 10 | |
| Full scale reading | 90 Counts | |
| Phase | ||
| Modes | A to B, B to A | |
| Range | 0 to 359 degrees | |
| Resolution | 1 degree | |
| Power (125B only) | ||
| Configurations | 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only) | |
| Power factor (PF) | Ratio between watts and VA range – 0.00 to 1.00 | |
| Watt | RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes) | |
| Full scale reading | 999 counts | |
| VA | Vrms x Arms | |
| Full scale reading | 999 counts | |
| VA reactive (var) | √((VA)2-W2) | |
| Full scale reading | 999 counts | |
| Vpwm | ||
| Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs | |
| Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency | |
| Accuracy | As Vrms for sinewave signals | |
User Manual
User Manual
Reviews (0)