Eurotron PLB 150 Portable Liquid Bath

Short Description:

Looking to buy Eurotron PLB 150 in KSA? Find competitive prices and exceptional offers right here!

Product purchase
SKU: 87246
Brand:Eurotron

Call for Best Price 00971(04) 447 6031 00971(04) 344 9868

14 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
Description

Eurotron PLB 150 Portable Liquid Bath

The Eurotron PLB 150 portable liquid bath features a large calibration volume of 60mm x 170mm deep, making it ideal for use as a portable liquid bath. Stirred liquid baths are suitable for temperature sensors of various types and shapes, offering smaller calibration uncertainties (stability, uniformity, and accuracy) compared to dry block calibrators.

As a liquid bath, the sensor is placed directly into the block without needing special drilled inserts. When used as a stirred liquid bath, the PLB 150 radon detector delivers enhanced performance comparable to larger, more expensive laboratory liquid baths. Since the fluid is inserted directly into the block, the overall performance of the PLB 150 surpasses similar products that use liquid containers. The magnetic stirrer ensures excellent homogeneity, and the speed can be adjusted using the onboard potentiometer to accommodate different fluid viscosities.

The PLB 150 Portable stirred liquid bath comes in two models:

  • PLB 150-TS Temperature calibrator/source with no inputs
  • PLB 150-TC Temperature Calibrator/source with inputs for reference sensor and sensor under test

Eurotron PLB 150 Key Features

  • Temperature range:-18 to 140 ºC
  • Large calibration volume: Ø 60 x 170 mm
  • Accuracy better than ±0.08 C using external reference sensor
  • High stability: ± 0.02 ºC
  • Best in class radial uniformity: ± 0.02 ºC
  • Inputs for reference sensor and sensor under test
  • Fully programmable ramp
  • Automatic switch test function
  • Use as stirred liquid bath, ice point, dry block, black body target and surface sensors temperature calibrator
  • RS232 and calibration software as standard

Eurotron PLB 150 Specifications

Temperature Range
@ 20ºC -18 C to 140 C
@ 0ºC -38 to 140°C
Stability
As Liquid Bath ± 0.01 °C
As Dry block ± 0.01 °C
Uniformity as Liquid Bath
Axial ± 0.02 °C @ -10 °C
± 0.02 °C@ 0°C
± 0.01 °C @ 120 °C
Radial ± 0.01 °C @ -10 °C
± 0.01 °C@ 0°C
± 0.02 °C @ 120 °C
Accuracy
with Internal Sensor ± 0.15 °C
with External Sensor SRS (*) ± 0.08 °C   ( TC version only)
Display 
Resolution user-selectable 0.1 , 0.01 C
Units user-selectable C, F,K
Calibration Volume
As Liquid Bath 54 x 150 mm
As dry block 60 x 170 mm
Heating time ambient to 120°C: 30 min ( include time to stability)
Cooling time ambient to -10°C : 30 min (include time to stability)
Thermocouple Input (TC version)
Type K,N,R,S,J,E
Range 0 to 1300 °C
Accuracy ± 1°C Include CJC error
Resolution user-selectable 0.1 , 0.01 °C
RTD’S input ( TC version only)
Type Pt 100 (3/4 wires)
Range -100 C to 700 °C
Accuracy ± 0.3 °C
Resolution user-selectable 0.1 , 0.01 °C
General
Computer interface RS 232 as standard ( UBS adapter supplied as option) and EIUK software included
Switch Test Yes
Ramp Yes fully programmable
Weight 8 Kg
Dimensions 160x340x330 mm
Power Requirement 115 o 230 V – 50/60 Hz
Power 300 VA
 Notes * Require SRS sensor and special UKAS matching calibration. Long term drift not included
Datasheet

Datasheet

Mme-Pdfs-Image

Specifications

Specifications

Eorotron PLB 150 Specifications

Temperature Range
@ 20ºC -18 C to 140 C
@ 0ºC -38 to 140°C
Stability
As Liquid Bath ± 0.01 °C
As Dry block ± 0.01 °C
Uniformity as Liquid Bath
Axial ± 0.02 °C @ -10 °C
± 0.02 °C@ 0°C
± 0.01 °C @ 120 °C
Radial ± 0.01 °C @ -10 °C
± 0.01 °C@ 0°C
± 0.02 °C @ 120 °C
Accuracy
with Internal Sensor ± 0.15 °C
with External Sensor SRS (*) ± 0.08 °C   ( TC version only)
Display 
Resolution user-selectable 0.1 , 0.01 C
Units user-selectable C, F,K
Calibration Volume
As Liquid Bath 54 x 150 mm
As dry block 60 x 170 mm
Heating time ambient to 120°C: 30 min ( include time to stability)
Cooling time ambient to -10°C : 30 min (include time to stability)
Thermocouple Input (TC version)
Type K,N,R,S,J,E
Range 0 to 1300 °C
Accuracy ± 1°C Include CJC error
Resolution user-selectable 0.1 , 0.01 °C
RTD’S input ( TC version only)
Type Pt 100 (3/4 wires)
Range -100 C to 700 °C
Accuracy ± 0.3 °C
Resolution user-selectable 0.1 , 0.01 °C
General
Computer interface RS 232 as standard ( UBS adapter supplied as option) and EIUK software included
Switch Test Yes
Ramp Yes fully programmable
Weight 8 Kg
Dimensions 160x340x330 mm
Power Requirement 115 o 230 V – 50/60 Hz
Power 300 VA