Fluke 123B/EU Industrial ScopeMeter 20MHz
- 20 MHz bandwidth industrial scope meter
- True-rms voltage and frequency measurements
- Dual input channels A and B
- 5000 count display with peak capture modes
- Current measurement with optional clamp
- Temperature and decibel measurements
- EU version with 123B frequency ranges up to 50 MHz
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 123B/EU Industrial ScopeMeter is a versatile handheld instrument designed for engineers and technicians who need to troubleshoot complex electrical systems in the field. Combining the functionality of an oscilloscope, multimeter, and data logger, this EU-certified model delivers accurate true-rms measurements across voltage, current, frequency, and power parameters. Its 20 MHz bandwidth and 5000-count display make it suitable for characterizing waveforms, verifying power quality, and diagnosing intermittent faults across industrial, commercial, and residential installations.
Fluke 123B/EU Key Features
This ScopeMeter provides comprehensive measurement capabilities including true-rms voltage readings on five ranges (500 mV to 750 V) and oscilloscope bandwidth of 20 MHz (DC to 20 MHz @ -3 dB). The dual-input design allows simultaneous monitoring of channels A and B, while peak capture modes (max, min, and pk-to-pk) identify transient events. Current measurement is supported via compatible current clamps with selectable scale factors, and optional temperature probes extend functionality to thermal profiling. Additional features include decibel measurements referenced to 600 or 50 ohms, duty cycle analysis, and RPM tracking up to 50 kRPM.
- DC voltage ranges: 500 mV, 5 V, 50 V, 500 V, 750 V
- Accuracy: ±(0.5% +5 counts)
- True-rms voltage (V ac, V ac+dc) on same ranges
- Oscilloscope bandwidth: DC to 20 MHz (-3 dB) (123B)
- Peak capture: Max, min, and pk-to-pk on 500 mV to 2200 V ranges
- Current clamp compatibility with selectable scale factors
- Decibel measurement referenced to 600 Ω or 50 Ω
- RPM measurement up to 50.00 kRPM
Who Needs the Fluke 123B/EU?
Field service engineers rely on the Fluke 123B/EU for rapid fault finding on motor drives, variable frequency drives, and power distribution panels where waveform analysis is critical. Maintenance technicians use it to verify harmonic content, measure insulation resistance indirectly through dB readings, and confirm proper operation of switching equipment. Electrical contractors appreciate the dual-input capability for comparing phase-to-phase and phase-to-neutral voltages simultaneously, reducing troubleshooting time on three-phase systems. Buyers and procurement teams value the EU certification and robust carrying case, ensuring the instrument meets regional safety standards and withstands demanding job site conditions.
The instrument’s compact design and intuitive interface make it accessible to junior technicians while retaining the accuracy required by senior engineers. Its ability to capture peak and RMS values in a single pass eliminates the need for separate meters, streamlining the diagnostic process. Whether verifying compliance on a new installation or diagnosing intermittent faults on an existing system, the 123B/EU provides the measurement versatility needed in today’s complex electrical environments.
Fluke 123B/EU Applications
Power quality auditors use the ScopeMeter to capture voltage sags, swells, and harmonic distortion on industrial feeders, generating reports that help facility managers optimize equipment performance. HVAC technicians measure variable frequency drive output waveforms to ensure proper motor speed control and identify installation issues. The decibel function simplifies cable loss measurements for communication system installers, while the RPM function tracks motor speed without requiring contact tachometer probes. Field service teams responding to power outages benefit from the true-rms accuracy and fast autoset frequency range to quickly identify the source of disturbances.
Panel builders and commissioning engineers use the 123B/EU to validate control system waveforms, verify VFD programming, and document startup conditions on new equipment. The peak capture modes are particularly useful for identifying nuisance trips caused by voltage transients or surge events. With its wide frequency range and true-rms capability, the instrument is also suitable for research and development laboratories characterizing new power electronic topologies where accurate waveform reproduction is essential.
Why Buy Fluke 123B/EU from mme-ae?
Mohammad Mahdi Electronics, trading as mme-ae, provides genuine Fluke instruments with full manufacturer warranty and regional support. When you purchase the Fluke 123B/EU from our store, you receive a CE-marked EU version designed for the local power grid specifications, ensuring compatibility with your existing infrastructure. Our technical team is available to assist with product selection, warranty claims, and accessory compatibility, giving you confidence that your investment is protected. We maintain stock of Fluke’s most popular test tools, reducing lead times for urgent maintenance projects.
Ordering from mme-ae also ensures you receive the complete package including the protective holster, test leads, and calibration certificate required for immediate deployment. Our after-sales support includes firmware updates and repair services through authorized Fluke service centers, minimizing downtime if the instrument requires attention. Trust Mohammad Mahdi Electronics for authentic Fluke testing solutions and the peace of mind that comes with genuine product coverage.
Complete your toolkit with the Fluke 123B/EU from mme-ae. Our knowledgeable staff can help you select the right current clamp or temperature probe to match your specific application needs. Contact us today to discuss how this versatile ScopeMeter can support your maintenance and troubleshooting objectives.
Fluke 123B/EU Specifications
| Input A and input B | ||
| DC voltage (VDC) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy | ±(0.5% +5 counts) | |
| Common mode rejection (CMRR) | >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz | |
| Full scale reading | 5000 counts | |
| True-rms voltages (V ac and V ac+dc) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V ac+dc) | ±(1% +10 counts) |
| 1 Hz to 60 Hz (V ac) | ±(1% +10 counts) | |
| Accuracy for 5% to 100% of range (AC or dc coupled) | 60 Hz to 20 kHz | ±(2.5% +15 counts) |
| DC rejection (only VAC) | >50 dB | |
| Common mode rejection (CMRR) | >100 dB @ dc | |
| >60 dB @ 50, 60, or 400 Hz | ||
| Full scale reading | 5000 counts, reading is independent of any signal crest factor. | |
| Peak | ||
| Modes | Max peak, Min peak, or pk-to-pk | |
| Ranges | 500 mV, 5 V, 50 V, 500 V, 2200 V | |
| Accuracy | Accuracy Max peak or Min peak | 5% of full scale |
| Accuracy Peak-to-Peak | 10% of full scale | |
| Full scale reading | 500 counts | |
| Frequency (Hz) | ||
| Ranges | 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz | |
| 124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz | ||
| Frequency range | 15 Hz (1 Hz) to 50 MHz in continuous autoset | |
| Accuracy @1 Hz to 1 MHz | ±(0.5% +2 counts) | |
| Full scale reading | 10,000 counts | |
| RPM | ||
| Max reading | 50.00 kRPM | |
| Accuracy | ±(0.5% +2 counts) | |
| Duty cycle (PULSE) | ||
| Range | 2% to 98% | |
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Pulse width (PULSE) | ||
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Full scale reading | 1000 counts | |
| Amperes (AMP) | ||
| With current clamp | Ranges | Same as V dc, V ac, V ac+dc, or PEAK |
| Scale factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA | |
| Accuracy | Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty) | |
| Temperature (TEMP) with optional temperature probe | ||
| Range | 200 °C/div (200 °F/div) | |
| Scale factor | 1 mV/°C and 1 mV/°F | |
| Accuracy | As V dc (add temp. probe uncertainty) | |
| Decibel (dB) | ||
| 0 dBV | 1 V | |
| 0 dBm (600 Ω /50 Ω) | 1 mW referenced to 600 Ω or 50 Ω | |
| dB on | V dc, V ac, or Vac+dc | |
| Full scale reading | 1000 counts | |
| Crest factor (CREST) | ||
| Range | 1 to 10 | |
| Full scale reading | 90 Counts | |
| Phase | ||
| Modes | A to B, B to A | |
| Range | 0 to 359 degrees | |
| Resolution | 1 degree | |
| Power (125B only) | ||
| Configurations | 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only) | |
| Power factor (PF) | Ratio between watts and VA range – 0.00 to 1.00 | |
| Watt | RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes) | |
| Full scale reading | 999 counts | |
| VA | Vrms x Arms | |
| Full scale reading | 999 counts | |
| VA reactive (var) | √((VA)2-W2) | |
| Full scale reading | 999 counts | |
| Vpwm | ||
| Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs | |
| Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency | |
| Accuracy | As Vrms for sinewave signals | |
Datasheet
Datasheet
User Manual
User Manual