Fluke 125B/EU Industrial ScopeMeter 40MHz
- 40 MHz bandwidth industrial scope meter
- True-rms voltage and current measurements
- Dual input channels A and B
- Oscilloscope bandwidth 40 MHz
- Power measurements for 1-phase and 3-phase systems
- Temperature, decibel and RPM functions
- Optional temperature probe compatibility
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 125B/EU Industrial ScopeMeter is a versatile 40 MHz handheld oscilloscope designed for field service and industrial maintenance professionals. Combining the functionality of an oscilloscope, multimeter, and power meter in a single compact unit, it enables technicians to troubleshoot complex electrical problems quickly and accurately. With its rugged design and intuitive interface, the ScopeMeter 125B/EU is built to withstand harsh workshop environments while delivering Fluke-quality measurements that engineers and electricians rely on daily.
Fluke 125B/EU Key Features
This Fluke ScopeMeter 125B/EU delivers comprehensive measurement capabilities across voltage, current, frequency, and power. Featuring true-rms accuracy on AC and DC coupled inputs, dual-channel analysis with independent scaling, and a wide bandwidth of 40 MHz, it captures transient events and waveform details that standard multimeters miss. The instrument includes oscilloscope bandwidth of 40 MHz, RPM measurement up to 50 kRPM, and duty cycle analysis from 2% to 98%, making it suitable for a broad range of industrial applications from motor troubleshooting to power quality analysis.
- DC voltage ranges: 500 mV, 5 V, 50 V, 500 V, 750 V
- True-rms AC and AC+DC voltage measurements
- Oscilloscope bandwidth: DC to 40 MHz (-3 dB) (125B)
- RPM measurement up to 50.00 kRPM
- Duty cycle range: 2% to 98%
- Peak detection: Max, Min, and pk-to-pk
- Current measurement with optional current clamp
- Temperature measurement with optional probe
- Decibel and power measurements
Who Needs the Fluke 125B/EU?
Field service technicians will appreciate the Fluke 125B/EU’s portable design and one-hand operation, allowing them to capture waveforms and measurements at the equipment without returning to a bench instrument. Maintenance engineers rely on its true-rms accuracy and wide frequency range to diagnose intermittent faults in variable frequency drives, motor controls, and power distribution systems. Electrical contractors value the dual-input capability for comparing phase-to-phase voltages and measuring power factor in three-phase systems, while procurement buyers benefit from Fluke’s reputation for reliability and the ScopeMeter’s all-in-one functionality that reduces the need for multiple test instruments on site.
The Fluke 125B/EU is equally valuable for automation specialists troubleshooting PLC I/O modules, HVAC technicians verifying sensor signals, and renewable energy installers checking inverter output quality. Its ability to measure true-rms voltage and current, capture peak values, and perform power analysis makes it an essential tool for anyone who needs to verify that electrical systems are operating within design parameters. From routine preventive maintenance to emergency fault finding, this ScopeMeter provides the measurement confidence needed to keep operations running smoothly.
Fluke 125B/EU Applications
In industrial motor control centers, the Fluke 125B/EU is used to monitor VFD output waveforms, check for harmonic distortion, and verify proper phase rotation before equipment startup. Power quality engineers utilize the ScopeMeter’s frequency analysis and true-rms capabilities to assess compliance with IEEE 519 standards and identify sources of electrical noise that can affect sensitive equipment. On production lines, technicians use the RPM and duty cycle functions to verify conveyor speed, motor synchronization, and machine cycle rates without interrupting production.
For building services and facility management, the Fluke 125B/EU excels at troubleshooting lighting systems, detecting nuisance tripping causes in circuit breakers, and verifying energy savings from LED retrofits. The decibel function allows audio-visual installers to verify signal levels and system gain, while the temperature measurement option (with optional probe) makes it useful for HVAC duct traversal and equipment temperature verification. Even field service companies working on telecommunications infrastructure find the ScopeMeter valuable for checking coaxial cable integrity and fiber optic power levels.
Why Buy Fluke 125B/EU from Mohammad Mahdi Electronics?
When you purchase the Fluke 125B/EU Industrial ScopeMeter from Mohammad Mahdi Electronics, you receive a genuine Fluke product with full manufacturer warranty and factory calibration documentation. Our team of measurement specialists can provide product guidance to ensure you select the right ScopeMeter configuration for your specific application needs, whether you require current clamp options, temperature probe compatibility, or specific frequency range coverage. We maintain stock of the most popular Fluke ScopeMeter models and offer prompt delivery across the UAE and GCC regions, minimizing downtime for your maintenance operations.
Mohammad Mahdi Electronics provides competitive pricing on Fluke test and measurement equipment, secure online ordering, and dedicated after-sales support. Our technical team is available to answer configuration questions, help with probe selection, and provide calibration service information to keep your Fluke 125B/EU performing at peak accuracy. Trust MME for your Fluke instrumentation needs and experience the difference that genuine products and expert service make.
Fluke 125B/EU Industrial ScopeMeter specifications provide the detailed performance data required for professional electrical measurements. The instrument features dual input channels with independent voltage ranges of 500 mV, 5 V, 50 V, 500 V, and 750 V for both DC and true-rms AC measurements. DC voltage accuracy stands at ±(0.5% +5 counts) across all ranges, while AC+DC accuracy ranges from ±(1% +10 counts) at 1 Hz to 60 Hz and ±(1% +10 counts) at 1 Hz to 60 Hz for AC-only measurements. Frequency measurement capability spans from 1 Hz to 70 MHz on the 125B model, with accuracy of ±(0.5% +2 counts) from 1 Hz to 1 MHz. True-rms voltage ranges mirror the DC ranges at 500 mV, 5 V, 50 V, 500 V, and 750 V, with AC accuracy from 1 Hz to 60 Hz at ±(1% +10 counts) and from 60 Hz to 20 kHz at the same specification. The ScopeMeter 125B/EU offers peak detection modes for Max, Min, and pk-to-pk measurements across ranges of 500 mV, 5 V, 50 V, 500 V, and 2200 V, with peak accuracy specified and pk-to-pk accuracy at 10% of full scale. Current measurement is facilitated through optional current clamps with scale factors ranging from 0.1 mV/A to 1 V/A, with accuracy matching the corresponding voltage function plus current clamp uncertainty. Temperature measurement is available with optional probes, ranging from 200 °C/div with a scale factor of 1 mV/°C, and accuracy following the DC voltage specification plus temperature probe uncertainty. Decibel measurements reference 0 dBV at 1 V and 0 dBm at 1 mW into 600 Ω or 50 Ω, while crest factor analysis ranges from 1 to 10 with full scale at 90 counts. Power measurement capabilities include true power (watts), VA, and VAR calculations for 1-phase and 3-phase systems, with full scale readings of 999 counts for both watts and VA. RPM measurement reaches up to 50.00 kRPM with accuracy of ±(0.5% +2 counts), and duty cycle analysis covers the 2% to 98% range with frequency coverage from 15 Hz to 30 MHz. The instrument features a full scale reading of 5000 counts for voltage functions and 10,000 counts for frequency measurements, with crest factor readings at 90 counts and decibel readings at 1000 counts. Phase measurement modes include A-to-B and B-to-A with 1-degree resolution across 0 to 359 degrees.
Shop the Fluke 125B/EU Industrial ScopeMeter at MME and equip your team with a reliable, all-in-one test and measurement solution. Our inventory includes the Fluke 125B/EU with EU power cord configuration, backed by Mohammad Mahdi Electronics’ commitment to genuine products and customer satisfaction. With fast shipping across the UAE and knowledgeable staff available to assist with product selection, MME is your trusted source for Fluke test and measurement equipment. Order today and experience the quality and support that only a Fluke supplier can provide.
Fluke 125B/EU Specifications
| Input A and input B | ||
| DC voltage (VDC) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy | ±(0.5% +5 counts) | |
| Common mode rejection (CMRR) | >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz | |
| Full scale reading | 5000 counts | |
| True-rms voltages (V ac and V ac+dc) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V ac+dc) | ±(1% +10 counts) |
| 1 Hz to 60 Hz (V ac) | ±(1% +10 counts) | |
| Accuracy for 5% to 100% of range (AC or dc coupled) | 60 Hz to 20 kHz | ±(2.5% +15 counts) |
| DC rejection (only VAC) | >50 dB | |
| Common mode rejection (CMRR) | >100 dB @ dc | |
| >60 dB @ 50, 60, or 400 Hz | ||
| Full scale reading | 5000 counts, reading is independent of any signal crest factor. | |
| Peak | ||
| Modes | Max peak, Min peak, or pk-to-pk | |
| Ranges | 500 mV, 5 V, 50 V, 500 V, 2200 V | |
| Accuracy | Accuracy Max peak or Min peak | 5% of full scale |
| Accuracy Peak-to-Peak | 10% of full scale | |
| Full scale reading | 500 counts | |
| Frequency (Hz) | ||
| Ranges | 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz | |
| 124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz | ||
| Frequency range | 15 Hz (1 Hz) to 50 MHz in continuous autoset | |
| Accuracy @1 Hz to 1 MHz | ±(0.5% +2 counts) | |
| Full scale reading | 10,000 counts | |
| RPM | ||
| Max reading | 50.00 kRPM | |
| Accuracy | ±(0.5% +2 counts) | |
| Duty cycle (PULSE) | ||
| Range | 2% to 98% | |
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Pulse width (PULSE) | ||
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Full scale reading | 1000 counts | |
| Amperes (AMP) | ||
| With current clamp | Ranges | Same as V dc, V ac, V ac+dc, or PEAK |
| Scale factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA | |
| Accuracy | Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty) | |
| Temperature (TEMP) with optional temperature probe | ||
| Range | 200 °C/div (200 °F/div) | |
| Scale factor | 1 mV/°C and 1 mV/°F | |
| Accuracy | As V dc (add temp. probe uncertainty) | |
| Decibel (dB) | ||
| 0 dBV | 1 V | |
| 0 dBm (600 Ω /50 Ω) | 1 mW referenced to 600 Ω or 50 Ω | |
| dB on | V dc, V ac, or Vac+dc | |
| Full scale reading | 1000 counts | |
| Crest factor (CREST) | ||
| Range | 1 to 10 | |
| Full scale reading | 90 Counts | |
| Phase | ||
| Modes | A to B, B to A | |
| Range | 0 to 359 degrees | |
| Resolution | 1 degree | |
| Power (125B only) | ||
| Configurations | 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only) | |
| Power factor (PF) | Ratio between watts and VA range – 0.00 to 1.00 | |
| Watt | RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes) | |
| Full scale reading | 999 counts | |
| VA | Vrms x Arms | |
| Full scale reading | 999 counts | |
| VA reactive (var) | √((VA)2-W2) | |
| Full scale reading | 999 counts | |
| Vpwm | ||
| Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs | |
| Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency | |
| Accuracy | As Vrms for sinewave signals | |
Datasheet
Datasheet
User Manual
User Manual
Reviews (0)
You must be logged in to post a review.
Bench Multimeters
Reviews
Clear filtersThere are no reviews yet.