Fluke 1529 Chub-E4 Standards Thermometer

Short Description:

The Fluke 1529 Chub-E4 Standards Thermometer is a robust device that combines precision, versatility, and advanced functionality. Its multi-sensor compatibility, customizable display, and powerful data-logging capabilities make it indispensable for professionals in calibration labs, research facilities, and industrial settings.

  • Log up to 8,000 readings with date and time stamps for data tracking.
  • –270 °C to 1800 °C Temperature Range
  • 0.01 to 0.001 ° Temperature Resolution
Product purchase
SKU: 106044

Call for Best Price 00971(04) 447 6031 00971(04) 344 9868

14 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
Description

Buy Fluke 1529

The Fluke 1529 Chub-E4 Standards Thermometer is a highly versatile and accurate device designed for temperature measurement and calibration. Its advanced features and multi-sensor compatibility make it ideal for laboratory, industrial, and field applications requiring precise and reliable data.

Key Features

The Fluke 1529 Chub-E4 offers a range of features that make it a standout choice for professionals:

  • Multi-Sensor Compatibility: It supports four channels for PRTs, thermistors, and thermocouples, allowing simultaneous readings from different sensor types. This flexibility makes it suitable for diverse applications.
  • Exceptional Accuracy: The Fluke 1529 thermometer delivers lab-quality accuracy, including ±0.004°C at -100°C for PRTs and ±0.0025°C at 25°C for thermistors. Thermocouple accuracy varies by type but remains highly reliable.
  • Advanced-Data Logging: The Chub-E4 simplifies data tracking and analysis by logging up to 8,000 measurements with date and time stamps.
  • Customizable Display: Users can select up to eight data fields from statistical functions, probe details, or utility settings to view on the large LCD screen. Temperature resolution options range from 0.01°C to 0.0001°C for detailed readings.
  • Fast Measurement Cycle: In high-speed mode, the device measures four sensors simultaneously at one-second intervals or one sensor at up to ten readings per second.

Additional Functionalities

The Fluke 1529 Chub-E4 is equipped with features that enhance usability and integration:

  • Flexible Input Options: It accepts various terminations, including bare wire, spade lug, or banana plugs for PRTs/thermistors, and miniature or standard connectors for thermocouples.
  • Power Options: It can operate on AC, DC, or an internal rechargeable NiMH battery that provides up to eight hours of operation without backlight.
  • Connectivity: Standard RS-232 communication allows easy PC integration for real-time data logging and analysis using optional software like LogWare II or MET/TEMP II. An IEEE-488 (GPIB) port is available as an upgrade for enhanced automation capabilities.

Applications

The Fluke 1529 is ideal for a variety of applications:

  • Laboratory calibration of sensors across multiple temperature ranges.
  • Field measurements in environmental chambers or industrial processes.
  • Automated calibration systems using MET/TEMP II software integration.

Fluke 1529 Specifications

The Fluke 1529 Chub-E4 Standards Thermometer has a temperature range of –270 °C to 1800 °C and a resolution of 0.01 to 0.001 °.

PRT / RTD Thermistor Thermocouple
Inputs 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering;
PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples)
Temperature Range –189 °C to 960 °C –50 °C to 150 °C –270 °C to 1800 °C
Measurement Range 0 to 400 Ω 0 to 500 KΩ –10 to 100 mV
Characterizations ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen Steinhart-Hart, YSI-400 NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial
Temperature Accuracy (meter only) ± 0.004 °C at –100 °C ± 0.0025 °C at 0 °C Ext. RJC Int. RJC
± 0.006 °C at 0 °C ± 0.0025 °C at 25 °C B at 1000 °C ± 0.6 °C ± 0.6 °C
± 0.009 °C at 100 °C ± 0.004 °C at 50 °C E at 600 °C ± 0.07 °C ± 0.25 °C
± 0.012 °C at 200 °C ± 0.010 °C at 75 °C J at 600 °C ± 0.1 °C ± 0.35 °C
± 0.018 °C at 400 °C ± 0.025 °C at 100 °C K at 600 °C ± 0.15 °C ± 0.4 °C
± 0.024 °C at 600 °C N at 600 °C ± 0.15 °C ± 0.3 °C
R at 1000 °C ± 0.4 °C ± 0.5 °C
S at 1000 °C ± 0.5 °C ± 0.6 °C
T at 200 °C ± 0.1 °C ± 0.3 °C
Temperature Resolution 0.001 ° 0.0001 ° 0.01 to 0.001 °
Resistance/Voltage Accuracy 0 Ω to 20 Ω: ± 0.0005Ω 0 Ω to 5 KΩ: ± 0.5 Ω –10 to 50 mV: ± 0.005 mV
20 Ω to 400 Ω: ± 25 ppm of rdg. 5 KΩ to 200 KΩ: ± 100 ppm of rdg. 50 to 100 mV: ± 100 ppm of rdg.
200 KΩ to 500 KΩ ± 300 ppm of rdg. Internal RJC: ± 0.25 °C)
Operating Range 16 °C to 30 °C
Measurement Interval 0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval
Excitation Current 1 mA, reversing 2 and 10 µA, automatically selected n/a
Display 33 x 127 mm (1.3 x 5 in) backlit LCD graphical display
Display Units °C, °F, K, Ω, KΩ, mV
Data Logging Up to 8,000 time- and date-stamped measurements can be logged
Logging Intervals 0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes
Averaging Moving average of most recent 2 to 10 readings, user selectable
Probe Connection Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations Universal receptacle accepts miniature and standard TC connectors
Communications RS-232 included, IEEE-488 (GPIB) optional
AC Power 100–240 V ac, 50-60 Hz, 0.4 A
DC Power 12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A)
Battery NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles
Size (HxWxD) 102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in)
Weight 2 kg (4.5 lb)
Calibration Accredited resistance and voltage calibrations are provided.

Buy the Fluke 1529 Chub-E4 Standards Thermometer to experience a perfect blend of precision, versatility, and advanced features in a durable design. This thermometer offers multi-sensor compatibility, a customizable display, and powerful data-logging capabilities, making it an essential tool for professionals in calibration labs, research facilities, and industrial environments.

Additional information
Inputs

2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering;
PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples)

Temperature Range

PRT / RTD: -189 °C to 960 °C
Thermistor: -50 °C to 150 °C
Thermocouple: -270 °C to 1800 °C

Measurement Range

PRT / RTD: 0 to 400 Ω
Thermistor: 0 to 500 KΩ
Thermocouple: -10 to 100 mV

Characterizations

PRT / RTD: ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen
Thermistor: Steinhart-Hart, YSI-400
Thermocouple: NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial

Temperature Accuracy (PRT / RTD)

± 0.004 °C at –100 °C
± 0.006 °C at 0 °C
± 0.009 °C at 100 °C
± 0.012 °C at 200 °C
± 0.018 °C at 400 °C
± 0.024 °C at 600 °C

Temperature Accuracy (Thermistor)

± 0.0025 °C at 0 °C
± 0.0025 °C at 25 °C
± 0.004 °C at 50 °C
± 0.010 °C at 75 °C
± 0.025 °C at 100 °C

Temperature Accuracy (Thermocouple)

Ext. RJC Int. RJC
B at 1000 °C ± 0.6 °C ± 0.6 °C
E at 600 °C ± 0.07 °C ± 0.25 °C
J at 600 °C ± 0.1 °C ± 0.35 °C
K at 600 °C ± 0.15 °C ± 0.4 °C
N at 600 °C ± 0.15 °C ± 0.3 °C
R at 1000 °C ± 0.4 °C ± 0.5 °C
S at 1000 °C ± 0.5 °C ± 0.6 °C
T at 200 °C ± 0.1 °C ± 0.3 °C

Temperature Resolution

PRT / RTD: 0.001 °
Thermistor: 0.0001 °
Thermocouple: 0.01 to 0.001 °

Resistance/Voltage Accuracy

PRT / RTD: 0 Ω to 20 Ω: ± 0.0005Ω, 20 Ω to 400 Ω: ± 25 ppm of rdg.
Thermistor: 0 Ω to 5 KΩ: ± 0.5 Ω, 5 KΩ to 200 KΩ: ± 100 ppm of rdg., 200 KΩ to 500 KΩ ± 300 ppm of rdg.
Thermocouple: –10 to 50 mV: ± 0.005 mV, 50 to 100 mV: ± 100 ppm of rdg., Internal RJC: ± 0.25 °C)

Measurement Interval

0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval

Operating Range

16 °C to 30 °C

Display

33 x 127 mm (1.3 x 5 in) backlit LCD graphical display

Display Units

°C, °F, K, Ω, KΩ, mV

Data Logging

Up to 8,000 time- and date-stamped measurements can be logged

Logging Intervals

0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes

Communications

RS-232 included, IEEE-488 (GPIB) optional

Power

AC Power: 100–240 V ac, 50-60 Hz, 0.4 A
DC Power: 12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A)
Battery: NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles

Size (HxWxD)

102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in)

Weight

2 kg (4.5 lb)

Datasheet

Datasheet

Datasheet

Datasheet

Specifications

Specifications

PRT / RTD Thermistor Thermocouple
Inputs 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering;
PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples)
Temperature Range –189 °C to 960 °C –50 °C to 150 °C –270 °C to 1800 °C
Measurement Range 0 to 400 Ω 0 to 500 KΩ –10 to 100 mV
Characterizations ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen Steinhart-Hart, YSI-400 NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial
Temperature Accuracy (meter only) ± 0.004 °C at –100 °C ± 0.0025 °C at 0 °C Ext. RJC Int. RJC
± 0.006 °C at 0 °C ± 0.0025 °C at 25 °C B at 1000 °C ± 0.6 °C ± 0.6 °C
± 0.009 °C at 100 °C ± 0.004 °C at 50 °C E at 600 °C ± 0.07 °C ± 0.25 °C
± 0.012 °C at 200 °C ± 0.010 °C at 75 °C J at 600 °C ± 0.1 °C ± 0.35 °C
± 0.018 °C at 400 °C ± 0.025 °C at 100 °C K at 600 °C ± 0.15 °C ± 0.4 °C
± 0.024 °C at 600 °C N at 600 °C ± 0.15 °C ± 0.3 °C
R at 1000 °C ± 0.4 °C ± 0.5 °C
S at 1000 °C ± 0.5 °C ± 0.6 °C
T at 200 °C ± 0.1 °C ± 0.3 °C
Temperature Resolution 0.001 ° 0.0001 ° 0.01 to 0.001 °
Resistance/Voltage Accuracy 0 Ω to 20 Ω: ± 0.0005Ω 0 Ω to 5 KΩ: ± 0.5 Ω –10 to 50 mV: ± 0.005 mV
20 Ω to 400 Ω: ± 25 ppm of rdg. 5 KΩ to 200 KΩ: ± 100 ppm of rdg. 50 to 100 mV: ± 100 ppm of rdg.
200 KΩ to 500 KΩ ± 300 ppm of rdg. Internal RJC: ± 0.25 °C)
Operating Range 16 °C to 30 °C
Measurement Interval 0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval
Excitation Current 1 mA, reversing 2 and 10 µA, automatically selected n/a
Display 33 x 127 mm (1.3 x 5 in) backlit LCD graphical display
Display Units °C, °F, K, Ω, KΩ, mV
Data Logging Up to 8,000 time- and date-stamped measurements can be logged
Logging Intervals 0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes
Averaging Moving average of most recent 2 to 10 readings, user selectable
Probe Connection Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations Universal receptacle accepts miniature and standard TC connectors
Communications RS-232 included, IEEE-488 (GPIB) optional
AC Power 100–240 V ac, 50-60 Hz, 0.4 A
DC Power 12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A)
Battery NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles
Size (HxWxD) 102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in)
Weight 2 kg (4.5 lb)
Calibration Accredited resistance and voltage calibrations are provided.