Fluke 5322A Electrical Safety Tester Calibrator
Short Description:
The Fluke 5322A Electrical Safety Tester Calibrator is a comprehensive and efficient solution for calibrating a wide range of electrical safety testing instruments. Its multifunctional capabilities, user-friendly features, and high precision make it invaluable for professionals seeking reliable and streamlined calibration processes.
- Simulate RCD, display Ripple coefficient and THD measurements, with multiple models available.
- Automate with MET/CAL software for improved consistency.
- 0.1 to 30 mA leakage current source
Call for Best Price 00971(04) 447 6031 00971(04) 344 9868
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Buy Fluke 5322A
The Fluke 5322A Electrical Safety Tester Calibrator is a versatile and comprehensive solution designed to streamline the calibration of various electrical safety testing instruments. By consolidating multiple functions into a single device, Fluke 5322A replaces the need for discrete resistors, decade boxes, and other custom setups, thereby enhancing efficiency and reducing complexity in calibration processes.
Key Features
The Fluke 5322A is equipped with a range of features that cater to diverse calibration requirements:
- Continuously Variable High Voltage Resistance Outputs: The Fluke 5322A feature allows users to source high-ohms, high-voltage resistors, facilitating the calibration of insulation resistance testers (megohmmeters) up to 5 kV. The ability to set any resistance value ensures compatibility with various device under test (DUT) specifications, including older hand-cranked testers.
- Active Loop Compensation (ALC): The ALC feature enhances the accuracy of loop/line impedance tester calibrations by compensating for residual impedance, ensuring precise measurements.
- 600 V Source: The built-in 600 V source is essential for calibrating voltage measurement functions in multifunction installation testers and other devices, providing a reliable and accurate voltage reference.
- 4-Wire Low Resistance Source: This capability enables accurate calibration of continuity testers and ground bond testers by sourcing low resistance values with high precision, ensuring the reliability of safety tests.
- High Voltage Measurement: The Fluke 5322A can directly measure high voltages up to 5 kV AC and DC without the need for external probes, offering improved measurement specifications and simplifying the calibration process.
- Leakage Current Source: With a range of 0.1 to 30 mA, this feature supports the calibration of leakage current testers by providing precise current sourcing capabilities.
- Residual Current Device (RCD) Simulation: The Fluke 5322A can simulate RCD trip currents, enabling the calibration of RCD testers and ensuring compliance with safety standards.
- Automation Compatibility: The calibrator is compatible with Fluke’s MET/CAL® software, allowing for automated calibration procedures that enhance throughput and consistency while reducing manual intervention.
Fluke 5322A Specifications
The Fluke 5322A is a versatile calibrator that supports insulation resistance up to 100 GΩ, high voltage measurements up to 5 kV, leakage current sourcing from 0.1 to 30 mA, and RCD trip current simulation from 5 to 150 mA, all with high accuracy and resolution.
General specifications | |
Specifications confidence levell | 99 % |
Specifications interval | 1 year |
Power line | 115/230 V ac (50/60 Hz) +10 % / -14 %, with the maximum voltage difference between neutral and protective earth not exceeding 15 V. Operation with power line between -10 % and -14 % has limitations in burden current for voltage outputs. See AC/DC Voltage Calibrator (VLC option) below. |
Power consumption | 1250 VA maximum |
Fuse protection | AC mains input: 2 A, 250 V for 230 V, time delay (T2L250 V – 5 mm x 20 mm) 4 A, 250 V for 115 V, time delay (T4L250 V – 5 mm x 20 mm) |
RCD input: 3.15 A, 250 V, fast (F3.15H250 V – 5 mm x 20 mm) | |
Meter amps (A) input: 20 A, 500 V, time delay (F20H500 V – 6.3 mm x 32 mm) | |
Loop/Line impedance input: 4 A, 500 V, time delay (T4H500 V – 6.3 mm x 32 mm) | |
Leakage current input: 100 mA, 250 V, fast (F100 mL250 V – 5 mm x 20 mm) | |
Environment | |
Warm-up time | 15 minutes |
Temperature performance | Operating temperature: 18 °C to 28 °C |
Calibration temperature (tcal): 23 °C | |
Temperature coefficient for temperatures outside of tcal ± 5 °C is 0.1 / °C of the specification, for temperatures between 5 °C to 40 °C. | |
Storage temperature : -10 °C to 50 °C | |
Storage recovery time: Typically <24 hours at operating temperature | |
Relative humidity (operating) | <80 % to 28 °C (resistance outputs >10 GΩ specified for <70 % to 28 °C) |
Relative humidity (storage) | 90 % non-condensing 0 °C to 50 °C |
Altitude | Operating: 2000 m (6561 ft) |
Storage: 12 200 m (40 000 ft) | |
Dimensions and weight | |
Dimensions | 430 mm x 555 mm x 170 mm (16.9 in x 21.8 in x 6.7 in) |
Weight | 20 kg (44.1 lb) |
Compliance | |
Safety | Mains: IEC 61010-1: Overvoltage category II, pollution degree 2 |
Measurement: IEC 61010-2-030: 5000 V (not category rated) | |
Electrical specifications | |
Low resistance source | |
Range | 100 mΩ to 10 kΩ + 10 mΩ single value selection, dc and line frequency (50/60 Hz) |
Leakage current source | |
Range | 0.1 to 30 mA |
Test voltage | Passive mode: 60 V ac to 250 V ac rms |
Differential mode: 60 V ac to 250 V ac rms | |
Substitute mode:10 V ac to 250 V ac rms | |
Active mode (5322A/VLC only)[1]: 50 V ac to 100 V ac rms | |
Uncertainty | Passive mode: ± (0.3% setting + 2 μA) |
Differential mode: ± (0.3% setting + 2 μA) | |
Test uncertainty can be influenced by power line voltage instability | |
Substitute mode: ± (0.3% setting + 2 μA) | |
Active mode (5322A/VLC only)[1]: ± (0.3% setting + 1 μA) | |
[1] The Active Mode outputs are synchronized with the ac mains frequency to suppress interference between the calibrator and external noise sources. | |
Human body simulation (for substitute leakage currently only | Resistance range: 0 Ω to 10 000 Ω |
Resolution: 1 Ω | |
Multimeter | |
Maximum withstand voltage | HV terminal to COM terminal: 5000 V rms |
V terminal to COM terminal: 1100 V rms | |
COM terminal to Protective Earth: 2200 V pk | |
AC/DC voltage range | V (1100 V) Input: 0 V dc to ±1100 V dc 10 mV to 1100 V ac rms |
HV (5000 V) Input: 0 Vdc to ±5000 Vdc 5 V to 5000 V ac rms | |
AC/DC current | |
Range | 0 A to 20 A continuous, 20 A to 30 A for up to 5 minutes, ac rms or dc |
AC power | |
Range | 0 kVA ac to 33 kVA ac |
Type | Apparent, active, reactive |
Phase indication | Phase angle (φ), Power Factor (PF) |
Phase uncertainty (dφ) | ± 0.1 ° |
DC power | |
Range | 0 to 33 kVA dc |
Buy the Fluke 5322A Electrical Safety Tester Calibrator for a comprehensive and efficient solution to calibrate a wide range of electrical safety testing instruments. This tool combines multifunctional capabilities with user-friendly features and high precision, making it an invaluable asset for professionals seeking reliable and streamlined calibration processes.
Specifications confidence levell |
99 % |
---|---|
Specifications interval |
1 year |
Power line |
115/230 V ac (50/60 Hz) +10 % / -14 %, with the maximum voltage difference between neutral and protective earth not exceeding 15 V. Operation with power line between -10 % and -14 % has limitations in burden current for voltage outputs. See AC/DC Voltage Calibrator (VLC option) below. |
Power consumption |
1250 VA maximum |
Fuse protection |
AC mains input: 2 A, 250 V for 230 V, time delay (T2L250 V – 5 mm x 20 mm) 4 A, 250 V for 115 V, time delay (T4L250 V – 5 mm x 20 mm) |
Warm-up time |
15 minutes |
Temperature performance |
Operating temperature: 18 °C to 28 °C |
Dimensions |
430 mm x 555 mm x 170 mm (16.9 in x 21.8 in x 6.7 in) |
Weight |
20 kg (44.1 lb) |
Low resistance source |
100 mΩ to 10 kΩ + 10 mΩ single value selection, dc and line frequency (50/60 Hz) |
Leakage current source range |
0.1 to 30 mA |
Leakage current source Test voltage |
Passive mode: 60 V ac to 250 V ac rms |
Leakage current source Uncertainty |
Passive mode: ± (0.3% setting + 2 μA) |
Maximum withstand voltage |
HV terminal to COM terminal: 5000 V rms |
AC/DC voltage range |
V (1100 V) Input: 0 V dc to ±1100 V dc 10 mV to 1100 V ac rms |
AC power |
Range: 0 kVA ac to 33 kVA ac |
DC power |
Range: 0 to 33 kVA dc |
Specifcations
General specifications | |
Specifications confidence levell | 99 % |
Specifications interval | 1 year |
Power line | 115/230 V ac (50/60 Hz) +10 % / -14 %, with the maximum voltage difference between neutral and protective earth not exceeding 15 V. Operation with power line between -10 % and -14 % has limitations in burden current for voltage outputs. See AC/DC Voltage Calibrator (VLC option) below. |
Power consumption | 1250 VA maximum |
Fuse protection | AC mains input: 2 A, 250 V for 230 V, time delay (T2L250 V – 5 mm x 20 mm) 4 A, 250 V for 115 V, time delay (T4L250 V – 5 mm x 20 mm) |
RCD input: 3.15 A, 250 V, fast (F3.15H250 V – 5 mm x 20 mm) | |
Meter amps (A) input: 20 A, 500 V, time delay (F20H500 V – 6.3 mm x 32 mm) | |
Loop/Line impedance input: 4 A, 500 V, time delay (T4H500 V – 6.3 mm x 32 mm) | |
Leakage current input: 100 mA, 250 V, fast (F100 mL250 V – 5 mm x 20 mm) | |
Environment | |
Warm-up time | 15 minutes |
Temperature performance | Operating temperature: 18 °C to 28 °C |
Calibration temperature (tcal): 23 °C | |
Temperature coefficient for temperatures outside of tcal ± 5 °C is 0.1 / °C of the specification, for temperatures between 5 °C to 40 °C. | |
Storage temperature : -10 °C to 50 °C | |
Storage recovery time: Typically <24 hours at operating temperature | |
Relative humidity (operating) | <80 % to 28 °C (resistance outputs >10 GΩ specified for <70 % to 28 °C) |
Relative humidity (storage) | 90 % non-condensing 0 °C to 50 °C |
Altitude | Operating: 2000 m (6561 ft) |
Storage: 12 200 m (40 000 ft) | |
Dimensions and weight | |
Dimensions | 430 mm x 555 mm x 170 mm (16.9 in x 21.8 in x 6.7 in) |
Weight | 20 kg (44.1 lb) |
Compliance | |
Safety | Mains: IEC 61010-1: Overvoltage category II, pollution degree 2 |
Measurement: IEC 61010-2-030: 5000 V (not category rated) | |
Electrical specifications | |
Low resistance source | |
Range | 100 mΩ to 10 kΩ + 10 mΩ single value selection, dc and line frequency (50/60 Hz) |
Leakage current source | |
Range | 0.1 to 30 mA |
Test voltage | Passive mode: 60 V ac to 250 V ac rms |
Differential mode: 60 V ac to 250 V ac rms | |
Substitute mode:10 V ac to 250 V ac rms | |
Active mode (5322A/VLC only)[1]: 50 V ac to 100 V ac rms | |
Uncertainty | Passive mode: ± (0.3% setting + 2 μA) |
Differential mode: ± (0.3% setting + 2 μA) | |
Test uncertainty can be influenced by power line voltage instability | |
Substitute mode: ± (0.3% setting + 2 μA) | |
Active mode (5322A/VLC only)[1]: ± (0.3% setting + 1 μA) | |
[1] The Active Mode outputs are synchronized with the ac mains frequency to suppress interference between the calibrator and external noise sources. | |
Human body simulation (for substitute leakage currently only | Resistance range: 0 Ω to 10 000 Ω |
Resolution: 1 Ω | |
Multimeter | |
Maximum withstand voltage | HV terminal to COM terminal: 5000 V rms |
V terminal to COM terminal: 1100 V rms | |
COM terminal to Protective Earth: 2200 V pk | |
AC/DC voltage range | V (1100 V) Input: 0 V dc to ±1100 V dc 10 mV to 1100 V ac rms |
HV (5000 V) Input: 0 Vdc to ±5000 Vdc 5 V to 5000 V ac rms | |
AC/DC current | |
Range | 0 A to 20 A continuous, 20 A to 30 A for up to 5 minutes, ac rms or dc |
AC power | |
Range | 0 kVA ac to 33 kVA ac |
Type | Apparent, active, reactive |
Phase indication | Phase angle (φ), Power Factor (PF) |
Phase uncertainty (dφ) | ± 0.1 ° |
DC power | |
Range | 0 to 33 kVA dc |