Fluke 5322A Electrical Safety Tester Calibrator

Short Description:

The Fluke 5322A Electrical Safety Tester Calibrator is a comprehensive and efficient solution for calibrating a wide range of electrical safety testing instruments. Its multifunctional capabilities, user-friendly features, and high precision make it invaluable for professionals seeking reliable and streamlined calibration processes.

  • Simulate RCD, display Ripple coefficient and THD measurements, with multiple models available.
  • Automate with MET/CAL software for improved consistency.
  • 0.1 to 30 mA leakage current source
Product purchase
SKU: 105423

Call for Best Price 00971(04) 447 6031 00971(04) 344 9868

15 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
Description

Buy Fluke 5322A

The Fluke 5322A Electrical Safety Tester Calibrator is a versatile and comprehensive solution designed to streamline the calibration of various electrical safety testing instruments. By consolidating multiple functions into a single device, Fluke 5322A replaces the need for discrete resistors, decade boxes, and other custom setups, thereby enhancing efficiency and reducing complexity in calibration processes.

Key Features

The Fluke 5322A is equipped with a range of features that cater to diverse calibration requirements:

  • Continuously Variable High Voltage Resistance Outputs: The Fluke 5322A feature allows users to source high-ohms, high-voltage resistors, facilitating the calibration of insulation resistance testers (megohmmeters) up to 5 kV. The ability to set any resistance value ensures compatibility with various device under test (DUT) specifications, including older hand-cranked testers.
  • Active Loop Compensation (ALC): The ALC feature enhances the accuracy of loop/line impedance tester calibrations by compensating for residual impedance, ensuring precise measurements.
  • 600 V Source: The built-in 600 V source is essential for calibrating voltage measurement functions in multifunction installation testers and other devices, providing a reliable and accurate voltage reference.
  • 4-Wire Low Resistance Source: This capability enables accurate calibration of continuity testers and ground bond testers by sourcing low resistance values with high precision, ensuring the reliability of safety tests.
  • High Voltage Measurement: The Fluke 5322A can directly measure high voltages up to 5 kV AC and DC without the need for external probes, offering improved measurement specifications and simplifying the calibration process.
  • Leakage Current Source: With a range of 0.1 to 30 mA, this feature supports the calibration of leakage current testers by providing precise current sourcing capabilities.
  • Residual Current Device (RCD) Simulation: The Fluke 5322A can simulate RCD trip currents, enabling the calibration of RCD testers and ensuring compliance with safety standards.
  • Automation Compatibility: The calibrator is compatible with Fluke’s MET/CAL® software, allowing for automated calibration procedures that enhance throughput and consistency while reducing manual intervention.

Fluke 5322A Specifications

The Fluke 5322A is a versatile calibrator that supports insulation resistance up to 100 GΩ, high voltage measurements up to 5 kV, leakage current sourcing from 0.1 to 30 mA, and RCD trip current simulation from 5 to 150 mA, all with high accuracy and resolution.

General specifications
Specifications confidence levell 99 %
Specifications interval 1 year
Power line 115/230 V ac (50/60 Hz) +10 % / -14 %, with the maximum voltage difference between neutral and protective earth not exceeding 15 V. Operation with power line between -10 % and -14 % has limitations in burden current for voltage outputs. See AC/DC Voltage Calibrator (VLC option) below.
Power consumption 1250 VA maximum
Fuse protection AC mains input: 2 A, 250 V for 230 V, time delay (T2L250 V – 5 mm x 20 mm) 4 A, 250 V for 115 V, time delay (T4L250 V – 5 mm x 20 mm)
RCD input: 3.15 A, 250 V, fast (F3.15H250 V – 5 mm x 20 mm)
Meter amps (A) input: 20 A, 500 V, time delay (F20H500 V – 6.3 mm x 32 mm)
Loop/Line impedance input: 4 A, 500 V, time delay (T4H500 V – 6.3 mm x 32 mm)
Leakage current input: 100 mA, 250 V, fast (F100 mL250 V – 5 mm x 20 mm)
Environment
Warm-up time 15 minutes
Temperature performance Operating temperature: 18 °C to 28 °C
Calibration temperature (tcal): 23 °C
Temperature coefficient for temperatures outside of tcal ± 5 °C is 0.1 / °C of the specification, for temperatures between 5 °C to 40 °C.
Storage temperature : -10 °C to 50 °C
Storage recovery time: Typically <24 hours at operating temperature
Relative humidity (operating) <80 % to 28 °C (resistance outputs >10 GΩ specified for <70 % to 28 °C)
Relative humidity (storage) 90 % non-condensing 0 °C to 50 °C
Altitude Operating: 2000 m (6561 ft)
Storage: 12 200 m (40 000 ft)
Dimensions and weight
Dimensions 430 mm x 555 mm x 170 mm (16.9 in x 21.8 in x 6.7 in)
Weight 20 kg (44.1 lb)
Compliance
Safety Mains: IEC 61010-1: Overvoltage category II, pollution degree 2
Measurement: IEC 61010-2-030: 5000 V (not category rated)
Electrical specifications
Low resistance source
Range 100 mΩ to 10 kΩ + 10 mΩ single value selection, dc and line frequency (50/60 Hz)
Leakage current source
Range 0.1 to 30 mA
Test voltage Passive mode: 60 V ac to 250 V ac rms
Differential mode: 60 V ac to 250 V ac rms
Substitute mode:10 V ac to 250 V ac rms
Active mode (5322A/VLC only)[1]: 50 V ac to 100 V ac rms
Uncertainty Passive mode: ± (0.3% setting + 2 μA)
Differential mode: ± (0.3% setting + 2 μA)
Test uncertainty can be influenced by power line voltage instability
Substitute mode: ± (0.3% setting + 2 μA)
Active mode (5322A/VLC only)[1]: ± (0.3% setting + 1 μA)
[1] The Active Mode outputs are synchronized with the ac mains frequency to suppress interference between the calibrator and external noise sources.
Human body simulation (for substitute leakage currently only Resistance range: 0 Ω to 10 000 Ω
Resolution: 1 Ω
Multimeter
Maximum withstand voltage HV terminal to COM terminal: 5000 V rms
V terminal to COM terminal:  1100 V rms
COM terminal to Protective Earth: 2200 V pk
AC/DC voltage range V (1100 V) Input:  0 V dc to ±1100 V dc 10 mV to 1100 V ac rms
HV (5000 V) Input: 0 Vdc to ±5000 Vdc 5 V to 5000 V ac rms
AC/DC current
Range 0 A to 20 A continuous, 20 A to 30 A for up to 5 minutes, ac rms or dc
AC power
Range 0 kVA ac to 33 kVA ac
Type Apparent, active, reactive
Phase indication Phase angle (φ), Power Factor (PF)
Phase uncertainty (dφ) ± 0.1 °
DC power
Range 0 to 33 kVA dc

Buy the Fluke 5322A Electrical Safety Tester Calibrator for a comprehensive and efficient solution to calibrate a wide range of electrical safety testing instruments. This tool combines multifunctional capabilities with user-friendly features and high precision, making it an invaluable asset for professionals seeking reliable and streamlined calibration processes.

Additional information
Specifications confidence levell

99 %

Specifications interval

1 year

Power line

115/230 V ac (50/60 Hz) +10 % / -14 %, with the maximum voltage difference between neutral and protective earth not exceeding 15 V. Operation with power line between -10 % and -14 % has limitations in burden current for voltage outputs. See AC/DC Voltage Calibrator (VLC option) below.

Power consumption

1250 VA maximum

Fuse protection

AC mains input: 2 A, 250 V for 230 V, time delay (T2L250 V – 5 mm x 20 mm) 4 A, 250 V for 115 V, time delay (T4L250 V – 5 mm x 20 mm)
RCD input: 3.15 A, 250 V, fast (F3.15H250 V – 5 mm x 20 mm)
Meter amps (A) input: 20 A, 500 V, time delay (F20H500 V – 6.3 mm x 32 mm)
Loop/Line impedance input: 4 A, 500 V, time delay (T4H500 V – 6.3 mm x 32 mm)
Leakage current input: 100 mA, 250 V, fast (F100 mL250 V – 5 mm x 20 mm)

Warm-up time

15 minutes

Temperature performance

Operating temperature: 18 °C to 28 °C
Calibration temperature (tcal): 23 °C
Temperature coefficient for temperatures outside of tcal ± 5 °C is 0.1 / °C of the specification, for temperatures between 5 °C to 40 °C.
Storage temperature : -10 °C to 50 °C
Storage recovery time: Typically <24 hours at operating temperature

Dimensions

430 mm x 555 mm x 170 mm (16.9 in x 21.8 in x 6.7 in)

Weight

20 kg (44.1 lb)

Low resistance source

100 mΩ to 10 kΩ + 10 mΩ single value selection, dc and line frequency (50/60 Hz)

Leakage current source range

0.1 to 30 mA

Leakage current source Test voltage

Passive mode: 60 V ac to 250 V ac rms
Differential mode: 60 V ac to 250 V ac rms
Substitute mode:10 V ac to 250 V ac rms
Active mode (5322A/VLC only)[1]: 50 V ac to 100 V ac rms

Leakage current source Uncertainty

Passive mode: ± (0.3% setting + 2 μA)
Differential mode: ± (0.3% setting + 2 μA)
Test uncertainty can be influenced by power line voltage instability
Substitute mode: ± (0.3% setting + 2 μA)
Active mode (5322A/VLC only)[1]: ± (0.3% setting + 1 μA)

Maximum withstand voltage

HV terminal to COM terminal: 5000 V rms
V terminal to COM terminal: 1100 V rms
COM terminal to Protective Earth: 2200 V pk

AC/DC voltage range

V (1100 V) Input: 0 V dc to ±1100 V dc 10 mV to 1100 V ac rms
HV (5000 V) Input: 0 Vdc to ±5000 Vdc 5 V to 5000 V ac rms

AC power

Range: 0 kVA ac to 33 kVA ac
Type: Apparent, active, reactive
Phase indication: Phase angle (φ), Power Factor (PF)
Phase uncertainty (dφ): ± 0.1 °

DC power

Range: 0 to 33 kVA dc

Datasheet

Datasheet

Datasheet

Datasheet

Specifcations

Specifcations

General specifications
Specifications confidence levell 99 %
Specifications interval 1 year
Power line 115/230 V ac (50/60 Hz) +10 % / -14 %, with the maximum voltage difference between neutral and protective earth not exceeding 15 V. Operation with power line between -10 % and -14 % has limitations in burden current for voltage outputs. See AC/DC Voltage Calibrator (VLC option) below.
Power consumption 1250 VA maximum
Fuse protection AC mains input: 2 A, 250 V for 230 V, time delay (T2L250 V – 5 mm x 20 mm) 4 A, 250 V for 115 V, time delay (T4L250 V – 5 mm x 20 mm)
RCD input: 3.15 A, 250 V, fast (F3.15H250 V – 5 mm x 20 mm)
Meter amps (A) input: 20 A, 500 V, time delay (F20H500 V – 6.3 mm x 32 mm)
Loop/Line impedance input: 4 A, 500 V, time delay (T4H500 V – 6.3 mm x 32 mm)
Leakage current input: 100 mA, 250 V, fast (F100 mL250 V – 5 mm x 20 mm)
Environment
Warm-up time 15 minutes
Temperature performance Operating temperature: 18 °C to 28 °C
Calibration temperature (tcal): 23 °C
Temperature coefficient for temperatures outside of tcal ± 5 °C is 0.1 / °C of the specification, for temperatures between 5 °C to 40 °C.
Storage temperature : -10 °C to 50 °C
Storage recovery time: Typically <24 hours at operating temperature
Relative humidity (operating) <80 % to 28 °C (resistance outputs >10 GΩ specified for <70 % to 28 °C)
Relative humidity (storage) 90 % non-condensing 0 °C to 50 °C
Altitude Operating: 2000 m (6561 ft)
Storage: 12 200 m (40 000 ft)
Dimensions and weight
Dimensions 430 mm x 555 mm x 170 mm (16.9 in x 21.8 in x 6.7 in)
Weight 20 kg (44.1 lb)
Compliance
Safety Mains: IEC 61010-1: Overvoltage category II, pollution degree 2
Measurement: IEC 61010-2-030: 5000 V (not category rated)
Electrical specifications
Low resistance source
Range 100 mΩ to 10 kΩ + 10 mΩ single value selection, dc and line frequency (50/60 Hz)
Leakage current source
Range 0.1 to 30 mA
Test voltage Passive mode: 60 V ac to 250 V ac rms
Differential mode: 60 V ac to 250 V ac rms
Substitute mode:10 V ac to 250 V ac rms
Active mode (5322A/VLC only)[1]: 50 V ac to 100 V ac rms
Uncertainty Passive mode: ± (0.3% setting + 2 μA)
Differential mode: ± (0.3% setting + 2 μA)
Test uncertainty can be influenced by power line voltage instability
Substitute mode: ± (0.3% setting + 2 μA)
Active mode (5322A/VLC only)[1]: ± (0.3% setting + 1 μA)
[1] The Active Mode outputs are synchronized with the ac mains frequency to suppress interference between the calibrator and external noise sources.
Human body simulation (for substitute leakage currently only Resistance range: 0 Ω to 10 000 Ω
Resolution: 1 Ω
Multimeter
Maximum withstand voltage HV terminal to COM terminal: 5000 V rms
V terminal to COM terminal:  1100 V rms
COM terminal to Protective Earth: 2200 V pk
AC/DC voltage range V (1100 V) Input:  0 V dc to ±1100 V dc 10 mV to 1100 V ac rms
HV (5000 V) Input: 0 Vdc to ±5000 Vdc 5 V to 5000 V ac rms
AC/DC current
Range 0 A to 20 A continuous, 20 A to 30 A for up to 5 minutes, ac rms or dc
AC power
Range 0 kVA ac to 33 kVA ac
Type Apparent, active, reactive
Phase indication Phase angle (φ), Power Factor (PF)
Phase uncertainty (dφ) ± 0.1 °
DC power
Range 0 to 33 kVA dc