Fluke 566 Multipurpose Thermometer
- Infrared measurement from -40°C to 800°C
- Type-K thermocouple input for expanded temperature range
- 50:1 distance-to-spot ratio for precision targeting
- USB interface with FlukeView Forms software
- Hi/Low alarms with data storage for 99 points
- Adjustable emissivity from 0.10 to 1.00
- Dot matrix display with backlight for dark environments
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 566 Multipurpose Thermometer is a versatile handheld instrument designed for professionals who need reliable temperature measurement across diverse applications. Combining infrared scanning with Type-K thermocouple input, this device allows users to measure surface temperatures from a distance as well as probe temperatures through its bead thermocouple input. The wide temperature ranges, from -40°C to 800°C infrared and -270°C to 1372°C via thermocouple, make it suitable for everything from HVAC diagnostics to industrial process monitoring. Its dual measurement methods and robust feature set ensure that technicians and engineers have the right tool for both quick spot checks and detailed temperature profiling.
Fluke 566 Key Features
The Fluke 566 delivers a comprehensive set of features designed for accuracy and ease of use in the field. With an infrared spectral response of 8 µm to 14 µm and a 50:1 distance-to-spot ratio, users can target specific areas with confidence. The instrument supports both infrared and thermocouple measurements, offering a Type-K input range that extends to 1372°C. Additional features include adjustable emissivity, built-in data storage with date/time stamps, and Hi/Low alarms that provide audible and two-color visual alerts. The switchable Celsius/Fahrenheit display and two-level backlight ensure readability in various lighting conditions.
- Infrared temperature range: -40°C to 800°C (-40°F to 1472°F)
- Infrared accuracy: < 0°C: ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); > 0°C: ±1% or ±1.0°C (±2.0°F), whichever is greater
- Display resolution: 0.1°C / 0.1°F
- Infrared spectral response: 8 µm to 14 µm
- Infrared response time: < 500 msec
- Thermocouple Type-K input range: -270°C to 1372°C (-454°F to 2501°F)
- D:S (distance to measurement spot size): 50:1
- Laser sighting: Single-point laser < 1 mw output Class 2 (II) operation
- Emissivity adjustment: Built-in table or digitally adjustable from 0.10 to 1.00 by 0.01
- Data storage with date/time stamp: 99 points
- PC interface: USB 2.0 with FlukeView® Forms software
- Hi/Low alarms: Audible and two-color visual
- Min/Max/Avg/Dif: Yes
- Display: Dot matrix 98 x 96 pixels with function menus
- Backlight: Two levels, normal and extra bright
- Trigger lock: Yes
- Switchable Celsius and Fahrenheit: Yes
- Power: 2 AA/LR6 Batteries and USB when used with a PC
- Battery life: If used continuously
- Operating temperature: 0°C to 50°C (32°F to 122°F)
- Storage temperature: -20°C to 60°C (-40°F to 140°F)
Who Needs the Fluke 566?
HVAC technicians will find the Fluke 566 indispensable for diagnosing heating and cooling systems, allowing them to measure vent temperatures and surface heat without direct contact. Maintenance engineers rely on the instrument’s broad temperature ranges and accuracy to monitor equipment health and prevent unexpected failures. The dual measurement capability—combining infrared scanning with Type-K thermocouple input—makes it ideal for electrical inspections where both surface and connection temperatures need verification. Buyers and procurement teams appreciate the Fluke brand reliability and the instrument’s versatility, which reduces the need for multiple specialized devices on site.
Field service professionals benefit from the Fluke 566’s rugged design and intuitive interface, enabling quick temperature assessments in challenging environments. The data storage function with date/time stamps is valuable for reporting and trend analysis, helping teams document findings over time. Whether performing routine checks or troubleshooting complex issues, the Fluke 566 provides the accuracy and flexibility needed to get the job done right the first time.
Fluke 566 Applications
In industrial settings, the Fluke 566 is used for monitoring motor temperatures, detecting overheating in electrical panels, and inspecting steam traps and valves without shutting down operations. Its high infrared accuracy and fast response time make it suitable for preventive maintenance programs that aim to reduce downtime and improve safety. The thermocouple input also allows for air temperature measurement in ducts and flues, providing a complete thermal picture of the system.
HVAC professionals use the Fluke 566 for balancing systems, checking refrigerant line temperatures, and verifying the performance of heat pumps and furnaces. The ability to switch between infrared and probe measurements means one tool can handle both surface temperature scans and air temperature readings in vents. Facility managers also rely on the instrument for regular energy audits and to identify insulation gaps or air leaks that impact overall efficiency.
Why Buy Fluke 566 from Mohammad Mahdi Electronics?
Mohammad Mahdi Electronics is the trusted source for genuine Fluke instruments in the UAE, ensuring that every Fluke 566 Multipurpose Thermometer sold comes with full manufacturer warranty and certification. When you purchase from MME, you benefit from authentic products, expert technical support, and fast delivery across the region. Our team understands the specific needs of local industries and can help you select the right testing tools for your applications, whether for routine maintenance or specialized industrial inspections.
Choosing Mohammad Mahdi Electronics means accessing the full Fluke product range with the confidence of buying from MME, MME of genuine Fluke instruments. We provide comprehensive after-sales service, including calibration support and accessory compatibility advice. Our commitment to customer satisfaction ensures that your investment in a Fluke 566 is protected, and our knowledgeable staff are available to answer technical questions and provide guidance on proper usage and maintenance.
Backed by Fluke’s reputation for durability and precision, the Fluke 566 is built to withstand the demands of daily field use while delivering consistent measurement results. The combination of infrared and thermocouple functionalities in a single handheld unit reduces equipment clutter and simplifies the technician’s toolkit. With features like laser sighting for target identification and adjustable emissivity for accurate readings on various surfaces, the Fluke 566 addresses the common challenges faced in temperature measurement across different materials and environments.
CTA paragraph goes here with company name rotation.
Fluke 566 Specifications
| Product Specifications | ||
| Infrared temperature range | -40°C to 800°C (-40°F to 1472°F) | |
| Infrared accuracy | < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); | |
| > 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater | ||
| Display resolution | 0.1°C / 0.1°F | |
| Infrared spectral response | 8 µm to 14 µm | |
| Infrared response time | < 500 msec | |
| Thermocouple Type-K input temperature range | -270°C to 1372°C (-454°F to 2501°F) | |
| Thermocouple Type-K input accuracy | -270°C to -40°C | ±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F)) |
| -40°C to 1372°C | ±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater | |
| D:S (distance to measurement spot size) | 50:1 | |
| Laser sighting | Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm | |
| Minimum spot size | 19 mm (0.75 in) | |
| Emissivity adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 | |
| Data storage with date/time stamp | 99 points | |
| PC interface and cable | USB 2.0 with FlukeView® Forms software | |
| Hi/Low alarms | Audible and two-color visual | |
| Min/Max/Avg/Dif | Yes | |
| Display | Dot matrix 98 x 96 pixels with function menus | |
| Backlight | Two levels, normal and extra bright for darker environments | |
| Trigger lock | Yes | |
| Switchable Celsius and Fahrenheit | Yes | |
| Power | 2 AA/LR6 Batteries and USB when used with a PC | |
| Battery life | If used continuously | Laser and backlight on,12 hours; laser and backlight off, 100 hours |
| Operating temperature | 0°C to 50°C (32°F to 122°F) | |
| Storage temperature | -20°C to 60°C (-40°F to 140°F) | |
| Bead thermocouple Type-K range | -40°C to 260°C (-40°F to 500°F) | |
| Bead thermocouple Type-K accuracy | ±1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F), typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) | |
Datasheet
Datasheet
User Manual
User Manual
Reviews (0)
You must be logged in to post a review.
Bench Multimeters
Reviews
Clear filtersThere are no reviews yet.