The Hioki M7100 Voltage/Temp Module is specifically designed for high-voltage battery pack applications, including electric vehicles (EVs) and energy storage systems (ESSs). It’s ideal for tasks that require high insulation performance and rapid data acquisition. This module can handle battery packs ranging from 600 V to 1500 V, making it suitable for next-generation batteries that exceed 800 V.
It’s important to note that the M7100 cannot function independently and must be used in conjunction with a compatible Hioki data logger, either the standard LR8101 or the advanced LR8102 model.
Hioki M7100 Key Features
- For 600 V to 1500 V battery packs
- 15ch, voltage and temperature (thermocouple) measurement
- High-precision measurement of cell voltage
- High-speed data capture, output of data for all cells at an interval as short as 5 ms, HIL support (*1)
Hioki M7100 Specifications
Compatible models | Data Logger LR8101: Standard model Data Logger LR8102: Advanced model |
---|---|
Operating temperature and humidity range | −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing) |
Withstand voltage | 7.4 kV AC for 1 minute (sensitivity current 1 mA) Between input channels (+, −) and LR8101 or LR8102, between modules 350 V AC for 1 minute (sensitivity current 1 mA), between input channels (+, −) |
Number of input channels | 15 channels |
Input terminal | M3 screw type terminal block (2 terminals per channel), equipped with terminal block cover |
Measurement parameters | Voltage Temperature (Thermocouple: K, J, E, T, N, R, S, B, C) |
Input method | Scan method using semiconductor relays, floating unbalanced input All channels isolated |
A/D resolution | 18 bits |
Maximum input voltage | ±100 V DC |
Maximum voltage between the channels | 300 V DC |
Maximum rated line-to-ground voltage | 1500 V DC in measurement category II, anticipated transient overvoltage 8000 V 1000 V AC in measurement category II, anticipated transient overvoltage 6000 V |
Maximum rated voltage between the modules | 1500 V DC, 1000 V AC |
Input resistance | 100 MΩ or more (voltage 10 mV f.s. to 6 V f.s. range, 1-5 V f.s. range, thermocouple all ranges) 1 MΩ ±5% (voltage 10 V f.s. to 100 V f.s. range) |
Data refresh interval | 5 ms (*1), 10 ms (*2), 20 ms, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s |
Measurement range | Voltage: 10 mV f.s., 20 mV f.s., 100 mV f.s., 200 mV f.s., 1 V f.s., 2 V f.s., 6 V f.s., 10 V f.s., 20 V f.s., 60 V f.s., 100 V f.s., 1-5 V f.s. Thermocouples: 100℃ f.s., 500℃ f.s., 2000℃ f.s. |
Dimensions and weight | Approx. 53W × 166H × 263D mm (2.1W × 6.5H × 10.4D in.), Approx. 1.3 kg (2.9 lbs) |
Included accessory | Instruction Manual ×1 |