-14%
MARMONIX MFU-6300 Wall Mounted Ultrasonic Flowmeter
Short Description:
You can purchase the MARMONIX MFU-6300 Wall-Mounted Ultrasonic Flow Meter, which provides a reliable and efficient solution for accurately measuring liquid flow in various applications.
- Principle: Ultrasonic transit-time principle, Four-byte IEEE754 floating-point arithmetic
- Accuracy: Better than ±1%
- Display LCD with Chinese English Display
Product purchase
AED 2,100 Original price was: AED 2,100.AED 1,800Current price is: AED 1,800. (excl.VAT)
17
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Buy MARMONIX MFU-6300
The MARMONIX MFU-6300 Wall Mounted Ultrasonic Flowmeter is a cutting-edge device designed to measure the flow of various liquids with high precision. Its wall-mounted design allows for easy installation in diverse environments, making it an ideal choice for industries requiring accurate flow measurements.
MARMONIX MFU-6300 Key Features
The MARMONIX MFU-6300 boasts several notable features:
- Versatile Liquid Measurement: Capable of measuring different kinds of liquids, enhancing its applicability across various sectors.
- Separate Installation of Transmitter and Transducer: The transmitter can be installed indoors, in instrument cabinets, or on dashboards, while the transducer is mounted on the pipes and connected by a special cable.
- High Accuracy and Reliability: Provides precise flow measurements, ensuring reliable data for monitoring and analysis.
- Ease of Installation: The separate installation of the transmitter and transducer allows for flexible setup in various environments.
- Durability: Built to withstand industrial conditions, ensuring longevity and consistent performance.
- Comprehensive Monitoring: Provides detailed flow data, facilitating informed decision-making in process management.
Applications
The MARMONIX MFU-6300 is widely used in:
- Production Monitoring: Assists in overseeing manufacturing processes by providing real-time flow data.
- Water Balance Testing: Essential for assessing water distribution and usage efficiency.
- Thermal Equilibrium Network Commissioning: Aids in setting up and maintaining thermal systems by monitoring fluid flow.
- Energy Monitoring: Contributes to energy management by tracking the flow of energy-carrying fluids.
MARMONIX MFU-6300 Specifications
The MARMONIX MFU-6300 Wall-Mounted Ultrasonic Flowmeter utilizes an ultrasonic transit-time principle with an accuracy of better than ±1%. It features a multilingual LCD, offers isolated RS485 and 4-20mA outputs, and operates effectively with various fluids from -30°C to 160°C, making it ideal for diverse industrial applications.
Type | Performance, Specification | |
Principle | Ultrasonic transit-time principle, Four-byte IEEE754 floating-point arithmetic | |
Accuracy | Better than ±1% | |
Display | LCD with Chinese English Display | |
One 4-20mA Current output,Impedance0-1K,Accuracy 0.1% | ||
Output | One OCT Pulse output(Width 6-1000ms,Default200ms) | |
Transmitter | One Relays output | |
Input | Three4-20mACurrentinput,accuracy0.1%, can collect temperature, pressure, level signals etc. | |
Can connect with three-wire PT100 Platinum resistance to measure heat flow | ||
Data Interface | Isolated RS485 interface, can upgrade flowmeter through PC, support mudbug | |
Cable | The average is below 50m; select RS485 Communication; transmission distance can be over a thousand meters. | |
material | Steel, Stainless steel, Cast iron, copper, PVC, aluminum, FRP etc.(liner allowed) | |
Pipe condition | Diameter | 15~6000mm |
Installation | Upstream 10D,downstream 5D,30D away from the pump outlet(D for diameter) | |
Medium | Fluid | Water, seawater, acid liquid, beer, alcohol, oil and any other liquid that can spread sonic |
Temperature | -30~160 degree C | |
Turbidity | 10000ppm and with little bubbles | |
Velocity | 0~±10m s | |
Operating Environment | Temperature | Transmitter:-20~60 degree C; Transducer:-30~160 degree C |
Humidity | Transmitter:85%RH;transmitter protection grade:IP68;Water Depth<2m | |
Power Supply | DC8-36V or AC85-264V | |
Consumption | 1.5W |
You can buy the MARMONIX MFU-6300 Wall-Mounted Ultrasonic Flow Meter, a reliable and efficient solution for accurately measuring liquid flow in various applications.
Accuracy |
Better than ±1% |
---|---|
Velocity |
0~±10m s |
Pipe size |
DN 15mm-DN 6000mm |
Display |
LCD display with Chinese, English Display, One 4-20mA Current output,Impedance0-1K,Accuracy 0.1% |
Signal output |
One OCT Pulse output(Width 6-1000ms,Default200ms) |
Signal input |
Three 4-20mACurrentinput,accuracy0.1%,cancollecttemperature,pressure,levelsignalsetc |
Pipe material |
Steel, Stainless steel, Cast iron, copper, PVC, aluminum, FRP etc.(liner allowed) |
Liquid types |
Water, sea water, acid liquid, beer, alcohol, oil and any other liquid that can spread sonic |
Power Supply |
DC8-36V or AC85-264V |
Straight Pipe section |
Upstream 10D,down stream 5D,30D away from the pump outlet(D for diameter) |
Liquid Temperature |
-30~160 degree C |
Liquid Turbidity |
10000ppm and with little bubbles |
Cable |
Normal below 50m;Select RS485 Communication, Transmission distance can over thousand meters. |
Specifications
Type | Performance, Specification | |
Principle | Ultrasonic transit-time principle, Four-byte IEEE754 floating-point arithmetic | |
Accuracy | Better than ±1% | |
Display | LCD display with Chinese, English Display | |
One 4-20mA Current output,Impedance0-1K,Accuracy 0.1% | ||
Output | One OCT Pulse output(Width 6-1000ms,Default200ms) | |
Transmitter | One Relays output | |
Input | Three4-20mACurrentinput,accuracy0.1%,cancollecttemperature,pressure,levelsignalsetc | |
Can connect with three-wire PT100 Platinum resistance to measure heat flow | ||
Data Interface | Isolated RS485 interface, can upgrade flowmeter through PC, support mudbug | |
Cable | Normal below 50m;Select RS485 Communication, Transmission distance can over thousand meters. | |
material | Steel, Stainless steel, Cast iron, copper, PVC, aluminum, FRP etc.(liner allowed) | |
Pipe condition | Diameter | 15~6000mm |
Installation | Upstream 10D,downstream 5D,30D away from the pump outlet(D for diameter) | |
Medium | Fluid | Water, sea water, acid liquid, beer, alcohol, oil and any other liquid that can spread sonic |
Temperature | -30~160 degree C | |
Turbidity | 10000ppm and with little bubbles | |
Velocity | 0~±10m s | |
Operating Environment | Temperature | Transmitter:-20~60 degree C; Transducer:-30~160 degree C |
Humidity | Transmitter:85%RH;transmitter protection grade:IP68;Water Depth<2m | |
Power Supply | DC8-36V or AC85-264V | |
Consumption | 1.5W |