MarMonix MIT 900 Infrared Thermometer
Genuine Marmonix MIT 900 non-contact thermometer for hot industrial surfaces, supplied in the UAE by MME, the authorised Marmonix distributor. Reads -50 to 950 °C with a 12:1 spot ratio and adjustable emissivity. Ask our team for a quotation or model advice.
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
Buying the MIT 900 high-temperature IR thermometer in the UAE
Plant engineers, maintenance contractors and inspection teams across the Emirates often need one handheld tool that can read very hot surfaces without contact. MME supplies the Marmonix MIT 900 as the brand’s authorised representative and distributor in the UAE, so you get genuine units, a formal quotation for your purchasing department and local technical help from our Dubai office.
Who uses this thermometer
- Metal, glass and cement plants: checking furnace casings, kiln walls and refractory linings during routine rounds.
- Oil and gas and utilities: surveying pipework insulation, steam lines and heat-exchanger bodies.
- Electrical maintenance teams: spot-checking terminals and cable lugs from a safe distance.
- Vehicle, marine and generator workshops: measuring exhaust, engine and turbo surfaces.
- Facility and HVAC contractors: confirming pipe and equipment surface temperatures.
Choosing the right model
Start with the hottest surface you expect to measure. The MIT 900 is the high end of the Marmonix MIT range at up to 950 °C. For lower-temperature work, compare the MIT 700 (up to 750 °C) and the MIT 550e. If you need to see heat patterns across a whole area rather than one spot, look at our thermal cameras. You can also browse all laser and infrared thermometers, the wider thermometers range and our temperature and humidity instruments.
MIT 900 specifications
| Parameter | Value |
|---|---|
| Temperature range | -50 to 950 °C (-58 to 1742 °F) |
| Accuracy (0 to 950 °C) | ±1.5 °C (±2.7 °F) or ±1.5%, whichever is greater |
| Accuracy (-50 to 0 °C) | ±3 °C (±5 °F) |
| Resolution | 0.1 °C / 0.1 °F |
| Repeatability | 1% of reading or 1 °C |
| Response time | 500 ms (95% response) |
| Spectral response | 8 to 14 µm |
| Emissivity | 0.10 to 1.00 adjustable (0.95 preset) |
| Distance-to-spot ratio | 12:1 |
| Operating temperature | 0 to 40 °C (32 to 104 °F) |
| Operating humidity | 10 to 95% RH, non-condensing; up to 30 °C (86 °F) |
| Storage temperature | -20 to 60 °C (-4 to 140 °F) |
| Power | 9V alkaline or NiCd battery |
| Typical battery life | 22 h without laser; 12 h with laser |
| Weight | 220 g |
Full technical details are also available on the Marmonix MIT 900 manufacturer’s product page.
Quotes and support from MME
Need several units for a site team, or help matching a model to your application? Contact our sales team for a quotation, and our technical staff for guidance on emissivity settings, alarms and day-to-day use after purchase.
Frequently asked questions
Is mme-ae an authorised source for Marmonix instruments in the UAE?
Yes. MME is the Marmonix representative and distributor in the UAE, so the MIT 900 we supply is genuine stock backed by the manufacturer, with local support from our Dubai team.
Can I get a formal quotation for a company or project order?
Yes. Send us the quantity, your company details and any project reference, and our sales team will issue a formal quotation including VAT for single units or multi-unit orders.
Which MIT model should I pick if my targets never exceed 550 °C?
If your surfaces stay below 550 °C, the MIT 550e covers that range. Pick the MIT 900 when any target, such as a furnace shell or exhaust, can run hotter than 750 °C.
Does the MIT 900 suit electrical panel inspections?
It is useful for spot-checking terminals, lugs and breaker bodies from a distance, because nothing needs to touch live parts. For scanning a whole panel at once, a thermal camera gives a faster overview.
What surface settings matter most for accurate readings?
Emissivity. The 0.95 default suits painted, oxidised and non-metallic surfaces; bare or polished metal needs a lower setting or a matt tape patch on the target.
Who can help me with setup or usage questions after purchase?
Our technical support team in Dubai can help with emissivity selection, alarm setup and general use. Contact us by phone or email with your invoice details.
{“@context”: “https://schema.org”, “@type”: “FAQPage”, “mainEntity”: [{“@type”: “Question”, “name”: “Is mme-ae an authorised source for Marmonix instruments in the UAE?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Yes. MME is the Marmonix representative and distributor in the UAE, so the MIT 900 we supply is genuine stock backed by the manufacturer, with local support from our Dubai team.”}}, {“@type”: “Question”, “name”: “Can I get a formal quotation for a company or project order?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Yes. Send us the quantity, your company details and any project reference, and our sales team will issue a formal quotation including VAT for single units or multi-unit orders.”}}, {“@type”: “Question”, “name”: “Which MIT model should I pick if my targets never exceed 550 °C?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “If your surfaces stay below 550 °C, the MIT 550e covers that range. Pick the MIT 900 when any target, such as a furnace shell or exhaust, can run hotter than 750 °C.”}}, {“@type”: “Question”, “name”: “Does the MIT 900 suit electrical panel inspections?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “It is useful for spot-checking terminals, lugs and breaker bodies from a distance, because nothing needs to touch live parts. For scanning a whole panel at once, a thermal camera gives a faster overview.”}}, {“@type”: “Question”, “name”: “What surface settings matter most for accurate readings?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Emissivity. The 0.95 default suits painted, oxidised and non-metallic surfaces; bare or polished metal needs a lower setting or a matt tape patch on the target.”}}, {“@type”: “Question”, “name”: “Who can help me with setup or usage questions after purchase?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Our technical support team in Dubai can help with emissivity selection, alarm setup and general use. Contact us by phone or email with your invoice details.”}}]}
Specifications
Specifications
| Feature | Specification |
|---|---|
| Model | Marmonix MIT 900 |
| Temperature Range | -50 ~ 950 °C (-58 ~ 1742 °F) |
| Accuracy | 0 ~ 950 °C (32 ~ 1742 °F): ±1.5 °C (±2.7 °F) or ±1.5% -50 ~ 0 °C (-58 ~ 32 °F): ±3 °C (±5 °F) Whichever is greater |
| Resolution | 0.1 °C / 0.1 °F |
| Repeatability | 1% of reading or 1 °C |
| Response Time | 500 ms (95% response) |
| Spectral Response | 8 ~ 14 µm |
| Emissivity | 0.10 ~ 1.00 adjustable (0.95 preset) |
| Distance-to-Spot (D:S) | 12 : 1 |
| Operating Temperature | 0 ~ 40 °C (32 ~ 104 °F) |
| Operating Humidity | 10 ~ 95% RH, non-condensing; up to 30 °C (86 °F) |
| Storage Temperature | -20 ~ 60 °C (-4 ~ 140 °F) |
| Power | 9V Alkaline or NiCd battery |
| Typical Battery Life | Non-laser mode: 22 hrs Laser mode: 12 hrs |
| Weight | 220 g |
| Dimensions | 175 × 100 × 49 mm |