MEGGER HIGH VOLTAGE TEST SETS T26/1A 200 kV, T26/1B 400 kV and T26/1C 800 kV
MEGGER Test Sets deliver high voltage testing up to 800kV for reliable insulation checks in electrical systems. Efficient and precise.
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
MEGGER HIGH VOLTAGE TEST SETS T26/1A 200 kV, T26/1B 400 kV and T26/1C 800 kV
The T 26/1A and T 26/1B high-voltage test sets are efficient, mobile systems for high-voltage testing of cables, cable systems and installations as required by current regulations (VDE) with DC voltages of up to 400 kV and 650 kV respectively.
The sets are suitable for both installation in measuring trailers and onsite testing as stationary test set. The spatial separation of the operating and high-voltage units makes it possible to operate the sets from outside the immediate danger area. Their modular structure makes them easy to set up on site and allows adaptation to measuring tasks.
MEGGER HIGH VOLTAGE TEST SETS T26/1A 200 kV, T26/1B 400 kV and T26/1C 800 kV Specifications:
- Output DC voltage:T 26/1 A: max. 400 kV (idling)max. 350 kV at 4 mA,T 26/1 B :max. 650 kV (idling)max. 600 kV at 3.5 mA,T 26/1 C :max. 860 kV (idling)max. 800 kV at 2 mA
- Short-circuit current: T 26/1 A: 300 m Arms,T 26/1 B :50 m Arms,T 26/1 C: 55 m Arms
- Voltage display:T 26/1 A: 60 kV … 480 kV,T 26/1 B: 60 kV … 720 kV,T 26/1 C :480 kV … 960 kV
- Current display:in 5 ranges 0.1 mA;1 mA; 10 mA; 100 mA; 300 mA;Automatic range switching up to 100 mA
- Switch clock:0 … max. 60 min
- Mains supply :220 V/240 V, 50/60 Hz external battery 12 V DC
- Power consumption: T 26/1 A max. 4.0 kVA,T 26/1 B max. 5.5 kVA,T 26/1 C max. 5.5 kVA
Specifications
| Model | Max Voltage (idling) | Max Voltage (at current) | Short-Circuit Current | Voltage Display Range | Power Consumption |
|---|---|---|---|---|---|
| T 26/1 A | 400 kV | 350 kV at 4 mA | 300 mArms | 60 kV – 480 kV | Max. 4.0 kVA |
| T 26/1 B | 650 kV | 600 kV at 3.5 mA | 50 mArms | 60 kV – 720 kV | Max. 5.5 kVA |
| T 26/1 C | 860 kV | 800 kV at 2 mA | 55 mArms | 480 kV – 960 kV | Max. 5.5 kVA |
| Current display: in 5 ranges (0.1 mA, 1 mA, 10 mA, 100 mA, 300 mA); Automatic range switching up to 100 mA | |||||
| Switch clock: 0 … max. 60 min | |||||
| Mains supply: 220 V/240 V, 50/60 Hz, external battery 12 V DC | |||||
1 review for MEGGER HIGH VOLTAGE TEST SETS T26/1A 200 kV, T26/1B 400 kV and T26/1C 800 kV
Clear filtersYou must be logged in to post a review.

Bench Multimeters
sam –
The MEGGER T26/1A, T26/1B, and T26/1C high voltage test sets are incredibly reliable for high voltage testing, offering precise and consistent results.