Megger LTC135 Load Tap Changer Testing Power Supply
The Megger LTC135 Load Tap Changer Testing Power Supply is specifically designed as an accessory for circuit breaker analyzers. It is used to test load tap changers by delivering test currents necessary for various measurements. The LTC135 is compatible with several Megger instruments, including the EGIL, TM1600/MA61, TM1700 series, and TM1800 models. This equipment is ideal for performing dynamic measurements on load tap changers, and it can also handle winding resistance measurements and other applications that require a consistent DC current test signal.
Megger LTC135 Key Features
- Winding Resistance Measurement
- Dynamic Resistance Measurement
- Switch sequence timing
- Transition/resistor measurement
Megger LTC135 Specifications
Specification Category | Details |
---|---|
General Conditions | Specifications valid at ambient temperature of +25°C (77°F). Changes to specifications without notice are possible. |
Environment | High-voltage substations and industrial environments. |
Temperature | Operation: -20ºC to +65°C (-4°F to +149°F) <br> Storage: -40ºC to +85ºC (-40°F to +185°F) |
Relative Humidity | 5%-95%, non-condensing |
Compliance | EMC 2004/108/EC, LVD 2006/95/EC |
General Specifications | Mains voltage: 100-250 V AC, 50/60 Hz <br> Power consumption: 300 W (max) <br> Dimensions: 360 x 195 x 300 mm (14.2 x 7.7 x 11.8 in.) <br> Weight: 6.5 kg (14.3 lbs) instrument only, 10.9 kg (24 lbs) with accessories and carrying case |
Outputs | Output current: 3 x 0.1 A, 3 x 1 A, 1 x 5 A <br> Open circuit voltage: 48 V <br> Output impedance: 480 Ω, 48 Ω, 9.6 Ω <br> Shunt output: 1 V/0.1 A, 1 V/1 A, 1 V/5 A <br> Shunt inaccuracy: 0.1% |
Measurement Range | EGIL and TM1600 (4 V): 0 – 44 Ω, 0 – 4.4 Ω, 0 – 850 mΩ <br> TM1700/1800 (15 V): 0 – 200 Ω, 0 – 20 Ω, 0 – 4 Ω |
Specifications
Specifications
Specification Category | Details |
---|---|
General Conditions | Specifications valid at ambient temperature of +25°C (77°F). Changes to specifications without notice are possible. |
Environment | High-voltage substations and industrial environments. |
Temperature | Operation: -20ºC to +65°C (-4°F to +149°F) <br> Storage: -40ºC to +85ºC (-40°F to +185°F) |
Relative Humidity | 5%-95%, non-condensing |
Compliance | EMC 2004/108/EC, LVD 2006/95/EC |
General Specifications | Mains voltage: 100-250 V AC, 50/60 Hz <br> Power consumption: 300 W (max) <br> Dimensions: 360 x 195 x 300 mm (14.2 x 7.7 x 11.8 in.) <br> Weight: 6.5 kg (14.3 lbs) instrument only, 10.9 kg (24 lbs) with accessories and carrying case |
Outputs | Output current: 3 x 0.1 A, 3 x 1 A, 1 x 5 A <br> Open circuit voltage: 48 V <br> Output impedance: 480 Ω, 48 Ω, 9.6 Ω <br> Shunt output: 1 V/0.1 A, 1 V/1 A, 1 V/5 A <br> Shunt inaccuracy: 0.1% |
Measurement Range | EGIL and TM1600 (4 V): 0 – 44 Ω, 0 – 4.4 Ω, 0 – 850 mΩ <br> TM1700/1800 (15 V): 0 – 200 Ω, 0 – 20 Ω, 0 – 4 Ω |
Reviews (0)
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Megger LTC135 Load Tap Changer Testing Power Supply” Cancel reply
You must be logged in to post a review.
Reviews
Clear filtersThere are no reviews yet.