- Range: 0.2 to 4 mS/cm | 2 to 40 CF | 140 to 2800 ppm 0.7 scale | 100 to 2000 ppm 0.5 scale
- Resolution: 0.1 mS/cm | 1 CF | 70 ppm (factor: 700 ppm = 1 mS/cm | 50 ppm (factor: 500 ppm = 1 mS/cm)
- Accuracy: ±4% of reading | ± 1 resolution point
- Temperature Compensation: Automatic 5 to 50°C / 41 to 122°F
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Buy Milwaukee EC40
The Milwaukee EC40 EC/TDS Nutrient Meter is a highly effective tool for measuring the conductivity of nutrient solutions. It is ideal for hydroponics, horticulture, and agriculture. This meter ensures that plants receive the appropriate nutrients necessary for healthy growth while minimizing waste.
Key Features
The Milwaukee EC40 is equipped with several features that enhance its functionality:
- Automatic Temperature Compensation (ATC): This feature automatically adjusts measurements based on temperature variations, ensuring accurate readings in different environmental conditions.
- Multiple Measurement Scales: The meter provides readings in various units, including mS/cm, CF, and ppm, allowing users to monitor nutrient levels without needing to perform conversions.
- User-Friendly Display: The device features a blue LED display with a graphical bar indicator that makes it easy to read results at a glance.
Applications
The Milwaukee EC40 is versatile and can be used in various applications:
- Hydroponics: For hydroponic growers, maintaining the right nutrient concentration is crucial. The EC40 helps monitor the conductivity of nutrient solutions to ensure optimal plant health.
- Horticulture: This meter assists in assessing soil and water quality in horticultural practices, enabling growers to adjust nutrient levels effectively.
- Agriculture: Farmers can use the EC40 to evaluate water quality and nutrient availability, helping them make informed decisions about fertilization practices.
Ease of Use
The Milwaukee EC40 is lightweight and portable, designed for convenience. Its waterproof design (IP67 rating) ensures durability in various environments. The meter features an auto shut-off function to conserve battery life, which can last up to three years with regular use. Additionally, the factory calibration means users can start measuring right away without complicated setup procedures.
Milwaukee EC40 Specifications
The Milwaukee EC40 EC/TDS Nutrient Meter measures electrical conductivity (0.2 to 4 mS/cm) and total dissolved solids (140 to 2800 ppm on the 0.7 scale and 100 to 2000 ppm).
| Range | 0.2 to 4 mS/cm |
| Range | 2 to 40 CF |
| Range | 140 to 2800 ppm 0.7 scale |
| Range | 100 to 2000 ppm 0.5 scale |
| Resolution | 0.1 mS/cm |
| Resolution | 1 CF |
| Resolution | 70 ppm (factor 700 ppm = 1 mS/cm) |
| Resolution | 50 ppm (factor 500 ppm = 1 mS/cm) |
| Accuracy | ±4% of reading, ± 1 resolution point |
| Calibration | Factory calibration (no additional calibration required) |
| Probe | Graphite electrode in ABC + PC body |
| Temperature Compensation | Automatic from 5 to 50°C (41 to 122°F) |
| Battery Type | 3 x 1.5V AA (included) |
| Battery Life | Approx. 3 years @ 10 tests per day |
| Measurement Display | 20 blue LED bar |
| Environment | 0 to 50°C / 32 to 122°F; max RH 95% |
| Dimensions | 17″ inches length (420 mm) / 30 mm diameter (1.2″) |
| Weight | 9 ounces (255 g) |
| Casing Protection | IP67, floating |
Buy the Milwaukee EC40 EC/TDS Nutrient Meter, an essential tool for anyone involved in hydroponics, horticulture, or agriculture. It offers automatic temperature compensation, multiple measurement scales, and a user-friendly design, ensuring accurate and reliable data on nutrient levels.
Specifications
| Range | 0.2 to 4 mS/cm |
| Range | 2 to 40 CF |
| Range | 140 to 2800 ppm 0.7 scale |
| Range | 100 to 2000 ppm 0.5 scale |
| Resolution | 0.1 mS/cm |
| Resolution | 1 CF |
| Resolution | 70 ppm (factor 700 ppm = 1 mS/cm) |
| Resolution | 50 ppm (factor 500 ppm = 1 mS/cm) |
| Accuracy | ±4% of reading, ± 1 resolution point |
| Calibration | Factory calibration (no additional calibration required) |
| Probe | Graphite electrode in ABC + PC body |
| Temperature Compensation | Automatic from 5 to 50°C (41 to 122°F) |
| Battery Type | 3 x 1.5V AA (included) |
| Battery Life | Approx. 3 years @ 10 tests per day |
| Measurement Display | 20 blue LEDs bar |
| Environment | 0 to 50°C / 32 to 122°F; max RH 95% |
| Dimensions | 17″ inches length (420 mm) / 30 mm diameter (1.2″) |
| Weight | 9 ounces (255 g) |
| Casing Protection | IP67, floating |