Milwaukee EC60 PRO Waterproof 3-in-1 EC / TDS/Temp Tester with Replaceable Probe
Short Description:
The Milwaukee Waterproof 3-in-1 EC/TDS/Temp Tester is essential for precise water quality measurements. With its waterproof design, multifunctionality, and replaceable probe, it’s ideal for hydroponics, aquaculture, laboratory research, and environmental monitoring. Users can maintain optimal conditions for better results and healthier ecosystems.
- EC Range: 0.00-20.00 mS/cm
- TDS Range 10.00 ppt
- Resolution: 0.01 mS/cm / 0.01 ppt / 0.1 C / 0.1 F
Buy Milwaukee EC60 PRO
The Milwaukee EC60 PRO Waterproof 3-in-1 EC/TDS/Temp Tester is a powerful tool designed for accurate water quality measurement. This device is particularly valuable in hydroponics and other agricultural practices, where maintaining optimal nutrient levels is crucial for plant health and growth. With its robust features and user-friendly design, the EC60 PRO stands out as an essential instrument for growers and researchers alike.
Key Features
The Milwaukee EC60 PRO offers several features that enhance its functionality:
- 3-in-1 Measurement: This tester measures electrical conductivity (EC), total dissolved solids (TDS), and temperature simultaneously, providing comprehensive insights into water quality.
- Waterproof Design: With an IP65 waterproof rating, the device is designed to withstand exposure to water, making it ideal for use in various environments without fear of damage.
- Replaceable Probe: The tester comes with a replaceable electrode, allowing users to maintain accuracy over time without needing to invest in a new unit.
- Automatic Temperature Compensation: This feature ensures that readings remain accurate despite fluctuations in temperature, which is essential for reliable data collection.
Applications
The Milwaukee EC60 PRO is versatile and suitable for a range of applications:
- Hydroponics: In hydroponic systems, maintaining the right nutrient concentration is vital. The EC60 PRO helps growers monitor nutrient levels effectively to promote healthy plant growth.
- Aquaculture: Monitoring water quality is critical for those involved in fish farming. The tester aids in ensuring that the water conditions are optimal for aquatic life.
- Laboratory Research: Researchers require precise measurements for experiments. The EC60 PRO provides reliable data necessary for scientific investigations in various fields.
- Environmental Monitoring: This device can also be used to assess water quality in natural bodies of water, helping environmentalists and conservationists monitor ecological health.
Milwaukee EC60 PRO Specifications
The Milwaukee EC60 PRO can measure EC in a range of 0.00 to 20.00 mS/cm, TDS in a range of 0.00 to 10.00 ppt, and TEMP in a range of 0.0 to 60.0 °C / 32.0 to 140.0 °F .
EC Range | 0.00 to 20.00 mS/cm |
TDS Range | 0.00 to 10.00 ppt |
Temp Range | 0.0 to 60.0 °C / 32.0 to 140.0 °F |
EC Resolution | 0.01 mS/cm |
TDS Resolution | 0.01 ppt |
Temp Resolution | 0.1°C / 0.1°F |
EC Accuracy | 2% Full Scale |
TDS Accuracy | 2% Full Scale |
Temp Accuracy | ±0.5°C / ±1°F |
EC Typical EMC Deviation | 2% Full Scale |
TDS Typical EMC Deviation | 2% Full-Scale Temp |
Typical EMC Deviation Temperature | ±0.5°C / ±1°F |
Calibration | Automatic, 1 point |
Temperature Compensation | Automatic, with β=0.0 to 2.4%/°C |
Probe | Mi59P (replaceable) |
Environment | 0 to 50°C / 32 to 122°F; max RH 100% |
Battery Type | 4 x 1.5V; IEC LR44, A76 (included) |
Battery Life | Approx. 100 hours of use |
Auto-off | After 8 minutes of non-use |
Dimensions | 200 x dia 38 mm |
Weight | 100 g |
Buy the Milwaukee Waterproof 3-in-1 EC/TDS/Temp Tester for essential and precise water quality measurements. Its waterproof design, multifunctionality, and replaceable probe make it an ideal choice for hydroponics, aquaculture, laboratory research, and environmental monitoring. Ensure you maintain optimal conditions for better results and healthier ecosystems.
EC Range, Resolution, Accuracy |
0.00 to 20.00 mS/cm ,0.01 mS/cm ,±2% Full Scale |
---|---|
Temp Range, Resolution, Accuracy |
0.0 to 60.0 °C / 32.0 to 140.0 °F / 32.0 to 140.0°F ,0.1°C / 0.1°F ,±0.5°C / ±1°F |
TDS Range, Resolution, Accuracy |
0.00 to 10.00 ppt ,0.01 ppt ,±2% Full Scale |
Temperature Compensation |
Automatic, with β=0.0 to 2.4%/°C |
Calibration |
Automatic, 1 point |
Environment |
0 to 50°C / 32 to 122°F; max RH 100% |
Power Supply |
Battery Type: 4 x 1.5V; IEC LR44, A76 (included) |
Weight |
100 g |
Dimensions |
200 x dia 38 mm |
Probe |
Mi59P (replaceable) |
Auto-off |
After 8 minutes of non-use |
Specifications
EC Range | 0.00 to 20.00 mS/cm |
TDS Range | 0.00 to 10.00 ppt |
Temp Range | 0.0 to 60.0 °C / 32.0 to 140.0 °F |
EC Resolution | 0.01 mS/cm |
TDS Resolution | 0.01 ppt |
Temp Resolution | 0.1°C / 0.1°F |
EC Accuracy | 2% Full Scale |
TDS Accuracy | 2% Full Scale |
Temp Accuracy | ±0.5°C / ±1°F |
EC Typical EMC Deviation | 2% Full Scale |
TDS Typical EMC Deviation | 2% Full Scale Temp |
Typical EMC Deviation Temperature | ±0.5°C / ±1°F |
Calibration | Automatic, 1 point |
Temperature Compensation | Automatic, with β=0.0 to 2.4%/°C |
Probe | Mi59P (replaceable) |
Environment | 0 to 50°C / 32 to 122°F; max RH 100% |
Battery Type | 4 x 1.5V; IEC LR44, A76 (included) |
Battery Life | Approx. 100 hours of use |
Auto-off | After 8 minutes of non-use |
Dimensions | 200 x dia 38 mm |
Weight | 100 g |
In stock