PCE-DC 25 Clamp Meter - 1000 A AC/DC, 1000 V, Bluetooth + Flex up to 3000 A

Brand: Pce
SKU: 97359
Share

The ergonomic design and user-friendly features of the PCE-DC 25 ensure that technicians can conduct safe and practical assessments even in challenging environments. For those who need a compact yet capable clamp meter, the PCE-DC 25 is an efficient and essential investment.

  • Clamp Meter DC Voltage measuring range: 600.0 mV DC to 1000 V DC
  • Clamp Meter AC Voltage measuring range: 6.000 V AC to 1000 V AC
  • Clamp Meter Resistance measuring range: 600.0 Ω to 60.00 MΩ
  • Safe Buy
  • Fast Delivery
  • Original Guarantee
  • Online Payment

Manual

Manual

Specifications

Clamp Meter PCE-DC 25
DC voltage
Measuring range 600.0 mV DC
Resolution 0.1 mV DC
Accuracy ±(0.5 % + 8 digits)
Measuring range 6.000 V DC
Resolution 0.001 V DC
Accuracy ±(1.5 % + 5 digits)
Measuring range 60.00 V DC
Resolution 0.01 V DC
Accuracy ±(1.5 % + 5 digits)
Measuring range 600.0 V DC
Resolution 0.1 V DC
Accuracy ±(1.5 % + 5 digits)
Measuring range 1000 V DC
Resolution 1 V
Accuracy ±(1.5 % + 5 digits)
Input impedance >10 MΩ
Overvoltage protection 1000 V AC/DC
AC voltage
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(1.5 % + 5 digits)
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(1.5 % + 5 digits)
Measuring range 600.0 V AC
Resolution 0.1 V AC
Accuracy ±(1.5 % + 5 digits)
Measuring range 1000 V AC
Resolution 1 V AC
Accuracy ±(1.5 % + 5 digits)
Peak value (PEAK) accuracy ±10 %
Peak value (PEAK) response time 1 ms
Input impedance >10 MΩ
Overvoltage protection 1000 V AC/DC
The accuracy relates to a measuring range of 10 … 100 %
with a sine wave.
Low pass filter (LowZ)
(50 … 400 Hz)
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(3.0 % + 40 digits)
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(3.0 % + 40 digits)
Measuring range 300.0 V AC
Resolution 0.1 V
Accuracy ±(3.0 % + 40 digits)
Input impedance <300 kΩ
Overvoltage protection 1000 V AC/DC
The accuracy relates to a measuring range of 10 … 100 %
with a sine wave.
AC with DC voltage
(50 … 400 Hz)
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(2.5 % + 20 digits)
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(2.5 % + 20 digits)
Measuring range 600.0 V AC
Resolution 0.1 V AC
Accuracy ±(2.5 % + 20 digits)
Measuring range 1000 V AC
Resolution 1 V AC
Accuracy ±(2.5 % + 20 digits)
Input impedance >10 MΩ
Direct current
Measuring range 600.0 A DC
Resolution 0.1 A DC
Accuracy ±(2.5 % + 5 digits)
Measuring range 1000 A DC
Resolution 1 A DC
Accuracy ±(2.8 % + 5 digits)
Overvoltage protection 1000 A DC
Alternating current
(50 … 60 Hz)
Measuring range 600.0 A AC
Resolution 0.1 A AC
Accuracy ±(2.5 % + 5 digits)
Measuring range 1000 A AC
Resolution 1 A AC
Accuracy ±(2.8 % + 5 digits)
Overload protection 1000 A AC/DC
Flexible clamp meter
(50 … 400 Hz)
Measuring range 30.00 A AC
Resolution 0.01 A AC
Accuracy ±(3.0 % + 5 digits)
Measuring range 300.0 A AC
Resolution 0.1 A AC
Accuracy ±(3.0 % + 5 digits)
Measuring range 3000 A AC
Resolution 1 A AC
Accuracy ±(3.0 % + 5 digits)
Overload protection 3000 A AC/DC
The accuracy relates to a measuring range of 10 … 100 %
with a sine wave.
Resistance
Measuring range 600.0 Ω
Resolution 0.1 Ω
Accuracy ±(1.0 % + 10 digits)
Measuring range 6.000 kΩ
Resolution 0.001 kΩ
Accuracy ±(1.5 % + 5 digits)
Measuring range 60.00 kΩ
Resolution 0.01 kΩ
Accuracy ±(1.5 % + 5 digits)
Measuring range 600.0 kΩ
Resolution 0.1 kΩ
Accuracy ±(1.5 % + 5 digits)
Measuring range 6.000 MΩ
Resolution 0.001 MΩ
Accuracy ±(2.5 % + 5 digits)
Measuring range 60.00 MΩ
Resolution 0.01 MΩ
Accuracy ±(3.5 % + 10 digits)
Overvoltage protection 1000 V AC/DC
Continuity test
Signal <50 Ω
Overvoltage protection 1000 V AC/DC
Diode test
Test current <1.5 mA
Maximum tension when open 3.3 V DC
circuit
Frequency measurement
Measuring range 9.999 Hz … 99.99 kHz
Resolution 0.01 … 10 Hz
Accuracy ±(1.2 % + 5 digits)
Overvoltage protection 1000 V AC/DC
Sensitivity >5 Vrms with one duty cycle
 from 20 … 80 %
Duty cycle
Measuring range 10.0 … 90.0 %
Resolution 0.10%
Accuracy ±(1.2 % + 8 digits)
Pulse range 40 Hz … 10 kHz
Pulse amplitude ±5 V (0.1 … 100 ms)
Capacity
Measuring range 60.00 nF
Resolution 0.01 nF
Accuracy ±(4.0 % + 20 digits)
Measuring range 600.0 nF
Resolution 0.1 nF
Accuracy ±(3.0 % + 8 digits)
Measuring range 6.000 µF
Resolution 0.001 µF
Accuracy ±(3.0 % + 8 digits)
Measuring range 60.00 µF
Resolution 0.01 µF
Accuracy ±(3.0 % + 8 digits)
Measuring range 600.0 µF
Resolution 0.1 µF
Accuracy ±(3.0 % + 8 digits)
Measuring range 6000 µF
Resolution 1 µF
Accuracy ±(5.0 % + 8 digits)
Measuring range 60.00 mF
Resolution 0.01 mF
Accuracy ±(5.0 % + 20 digits)
Measuring range 100.0 mF
Resolution 0.1 mF
Accuracy ±(5.0 % + 20 digits)
Overvoltage protection 1000 V AC/DC
Temperature measurement
(Thermocouple Type K)
Measuring range -40 … 600.0 °C
Resolution 0.1 °C
Accuracy ±(1.5 % + 5 digits)
Measuring range 600 … 1000 °C
Resolution 1 °C
Accuracy ±(1.5 % + 5 digits)
Measuring range -40 … 600.0 °F
Resolution 0.1 °F
Accuracy ±(1.5 % + 9 digits)
Measuring range 600 … 1800 °F
Resolution 1 °F
Accuracy ±(1.5 % + 9 digits)
Overvoltage protection 1000 V AC/DC
The accuracy refers to the measuring device without temperature probe.
Specifications refer to a stable ambient condition of ±1 °C.
If the measurement lasts for a long time, the measured value increases by 2 °C
Further specifications
Clamp opening 34 mm / 1.3″
NCV >150 V AC
Display LC colour display
Display when measuring range exceeded “OL” (overload)
Measuring rate 3 measured values per second
Interface Bluetooth
Operating conditions 5 … 40 °C / 41 … 104 °F
<80 % RH non-condensing at
31 °C / 87 °F linearly decreasing to 50 % RH
non-condensing at 40 °C / 104 °F
Storage conditions -20 … 40 °C / -4 … 140 °F <80 % RH
 non-condensing
Maximum working height 2000 m / 7000 ft
Power supply 3 x 1.5 V AAA batteries
Auto power off Switched off, 15, 30, 45, 60 minutes
Dimensions 250 x 80 x 40 mm / 9.8 x 3.1 x 1.5″
Weight 365 g / 12.8 oz