Hioki

(0)
Call for price
  • Supported device: Super MΩ HiTester SM7810
  • Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
  • Generation accuracy: High-precision power source unit
  • Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
  • Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
  • Interfaces: GP-IB, RS-232C, EXT I/O
  • Power supply: 100 V AC or 220 V AC, 50/60 Hz, 860 VA
  • Dimensions and mass: 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 47 kg (1657.9 oz)
(0)
Call for price
  • Supported device: Super MΩ HiTester SM7810
  • Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
  • Generation accuracy: High-precision power source unit
  • Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
  • Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
  • Interfaces: GP-IB, RS-232C, EXT I/O
  • Power supply: 100 V AC or 220 V AC, 50/60 Hz, 860 VA
  • Dimensions and mass: 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 47 kg (1657.9 oz)
(0)
Call for price
  • Supported device: Super MΩ HiTester SM7810
  • Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
  • Generation accuracy: High precision
  • Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
  • Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
  • Interfaces: GP-IB, RS-232C, EXT I/O
  • Power supply: 100 V AC, 220 V AC, 50/60 Hz, 860 VA
  • Dimensions and mass: 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 47 kg (1657.9 oz)
(0)
Call for price
  • Supported device: Super MΩ HiTester SM7810
  • Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
  • Generation accuracy: High-precision power source unit
  • Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
  • Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
  • Interfaces: GP-IB, RS-232C, EXT I/O
  • Power supply: 100 V AC or 220 V AC, 50/60 Hz, 860 VA
  • Dimensions and mass: 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 47 kg (1657.9 oz)
(0)
Call for price
  • Power Supply Unit for Hioki HiTESTER SM7810
  • Supports Super MΩ HiTester SM7810
  • ±2% output voltage accuracy
  • ±0.01 V inter-channel error
  • GP-IB, RS-232C, EXT I/O interfaces
  • 100 V AC or 220 V AC power supply
  • Dimensions: 425 mm W × 249 mm H × 581 mm D, 47 kg
(0)
Call for price
  • Hioki SM7860-52 POWER SOURCE UNIT is a reliable power source unit designed for various applications.
  • It supports the Super MΩ HiTester SM7810 and provides accurate output voltage.
  • The unit features GP-IB, RS-232C, and EXT I/O interfaces for seamless connectivity.
  • It is powered by 100 V AC or 220 V AC, 50/60 Hz, 860 VA.
  • The unit measures 425 mm W × 249 mm H × 581 mm D and weighs 47 kg.
  • It includes a power cable, instruction manual, and operating precautions.
  • Choose electrical instruments from MME for your power source needs.
  • Learn more about electrical safety standards to ensure safe usage.
  • Discover the full range of Hioki instruments at Mohammad Mahdi Electronics.
(0)
Call for price
  • Supported device: Super MΩ HiTester SM7810
  • Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
  • Generation accuracy: High-precision power source unit
  • Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
  • Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
  • Interfaces: GP-IB, RS-232C, EXT I/O
  • Power supply: 100 V AC, 220 V AC, 50/60 Hz, 860 VA
  • Dimensions and mass: 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 47 kg (1657.9 oz)
(0)
Call for price
  • 8 channels for parallel and simultaneous measurement
  • Supply voltage from external power source
  • Measurement range from 1 pA to 1 mA and 1 × 10^2 Ω to 1 × 10^15 Ω
  • FAST measurement speed of 6.8 ms
  • Basic measurement accuracy of ±(2.0+ (0.5 µA / (Measured current value)) ) %
  • Testing voltage setting from 0.1 V to 1000.0 V
  • Contact check function to judge contact state
(0)
Call for price
  • High-precision super megohm meter for insulation resistance testing
  • Measures resistance from 1 × 10^3 Ω to 2 × 10^19 Ω
  • DC current measurement: 20 pA to 2 mA range
  • Resistance measurement accuracy defined by current range accuracy and voltage setting accuracy
  • Programmable functions: 10 types of discharge, charge, measure and measurement sequence discharge patterns
  • Interfaces: USB, RS-232C, GP-IB, EXT I/O (NPN/PNP can be switched)
  • Power supply: 100 to 240V AC, 50/60 Hz, 45 VA
(0)
Call for price
  • Cloud-based data management software for electrical measurement data
  • Free plan available with basic functions
  • Standard and Pro licenses available for enhanced features
  • Secure data storage and collaboration
  • Integration with Hioki instruments
  • Scalable and customizable
  • Regular software updates
  • 24/7 technical support
(0)
Call for price
  • Bluetooth(R) connection for seamless data transfer
  • Local, e-mail / cloud sharing for convenient data management
  • Various template reports for efficient data analysis
  • Picture / Memo recording for detailed documentation
  • General measurement and logging capabilities
  • Pass/Faile judge and Photo/Drawing with Values Measurement
  • Waveform display for CM/DT series
(0)
Call for price
  • Real-time data logging and monitoring of electrical parameters.
  • Supports up to 512 items for monitoring and logging.
  • Continuous measurement and set time recording options.
  • File segmentation for efficient data storage.
  • Max. 30 units connection capability.
  • Supports various measurement items such as temperature, analog input, etc.
  • Calculation between channels for advanced analysis.
(0)
Call for price
  • Read-compatible model: PW3360 series, PW3365 series, 3169 series
  • Supported computer OS: Computer running under Windows 10 (32bit/64bit), Windows 8/8.1 (32bit/64bit), Windows 7 SP1 or later (32bit/64bit)
  • Trend graph display function: Display item: Voltage, current, active power, reactive power, apparent power, power factor, frequency, integrated active power, integrated reactive power, demand volume, demand value, voltage disequilibrium factor, Pulse, Harmonics (level, content, phase angle, total value, THD)
  • Summary Display Function: Displayed items are the same as for Trend Graph Display
  • Daily, weekly and monthly report displays: Accumulates and displays daily, weekly and monthly reports over specified period
  • Load factor calculation display: Calculates and displays load factor and demand factor results with daily, weekly and monthly reports
  • Time span aggregation: Aggregates data into up to four specified time spans
  • Waveform display: Displays waveform data at specified date
  • Harmonic display: List display: Displays a list of harmonic data at specified date, Graph display: Displays a bar graph of harmonic data at specified date, Cursor calculation: Calculates measurement data at cursors in waveform and graph displays
  • Copy function: Captures any display image to the clipboard
  • Print Function: Preview and print content shown on the trend graph, report, harmonic graph and settings displays
(0)
Call for price
  • Accurate and reliable resistance measurements
  • Wide range of applications in electrical testing and measurement
  • High-quality construction for durability and longevity
  • Easy-to-use interface for simplified operation
  • Compact design for convenient portability
  • Meets or exceeds industry standards for safety and performance
  • Long-lasting battery life for extended use
(0)
Call for price
  • Resistance range: 10 mΩ to 1000 MΩ
  • Measurement accuracy: ±0.006 % rdg. ±0.001 % f.s.
  • Testing current: 1 A DC to 1 µA or less
  • Temperature measurement: -10.0°C to 99.9°C
  • Measurement speed: FAST (2.2 ms) to SLOW2 (202 ms)
  • Functions: Temperature correction, temperature conversion, offset voltage compensation (OVC), comparator (ABS/ REF%), BIN, key-lock (OFF, menu lock, all lock)
(0)
Call for price
  • Resistance range: 30 mΩ to 3 MΩ
  • Measurement accuracy: ±0.020 % rdg. ±0.007 % f.s.
  • Testing current: 300 mA DC to 500 nA DC
  • Open-terminal voltage: 5.5 V DC max.
  • Temperature measurement: -10.0 °C to 99.9°C
  • Measurement speed: FAST, MED, SLOW
  • Display refresh rate: N/A
  • Functions: Temperature correction, comparator, key-lock, display digit count selection
(0)
Call for price
  • Four-terminal, constant-current DC measurement method
  • Resistance range: 10 mΩ to 1000 Ω
  • Monochrome graphic LCD display with white LED backlight
  • Measurement accuracy: ±0.060 % rdg. ±0.001 % f.s.
  • Testing current: 1 A DC to 1 mA DC
  • Open-terminal voltage: 20 V DC max.
  • Sampling rate: FAST, MEDIUM, SLOW, 3 settings
  • Integration time: 0.1 ms to 100.0 ms
  • Other functions: Comparator, Delay, OVC, Average, Measurement fault detection, etc.
(0)
Call for price
  • Resistance range: 100 mΩ to 100 MΩ, 10 steps
  • Display: Monochrome graphic LCD 240 × 64 dot, white LED backlight
  • Measurement accuracy: ±0.015 % rdg. ±0.002 % f.s.
  • Testing current: 100 mA DC to 100 nA DC
  • Open-terminal voltage: 20 V DC max.
  • Sampling rate: FAST, MEDIUM, SLOW, 3 settings
  • Measurement times: 0.9 ms to 17 ms
  • Integration time: 0.1 ms to 100.0 ms
(0)
Call for price
  • Resistance range: 100 mΩ to 100 MΩ, 10 steps
  • Measurement accuracy: ±0.015 % rdg. ±0.002 % f.s.
  • Testing current: 100 mA DC to 100 nA DC
  • Display: Monochrome graphic LCD 240 × 64 dot, white LED backlight
  • Power supply: 100 to 240 V AC, 50/60 Hz, 30 VA max.
  • Dimensions: 260 mm W × 88 mm H × 300 mm D, 2.9 kg
(0)
Call for price
  • Resistance range: 100 mΩ to 100 MΩ, 10 steps
  • Measurement accuracy: ±0.015 % rdg. ±0.002 % f.s.
  • Testing current: 100 mA DC to 100 nA DC
  • Open-terminal voltage: 20 V DC max.
  • Sampling rate: FAST, MEDIUM, SLOW, 3 settings
  • Measurement times: 0.9 ms to 17 ms
  • Integration time: 0.1 ms to 100.0 ms
  • Other functions: Comparator, Delay, OVC, Measurement fault detection, etc.
(0)
Call for price
  • Power Quality Analyzers (PQA) from Hioki
  • Monitor and analyze power quality issues
  • Improve power efficiency and reliability
  • Compliant with international standards
  • Wide range of applications
  • Reliable and accurate measurements
  • Easy to use and maintain
(0)
Call for price
  • Accurate power measurement for various applications
  • Reliable data logging for energy analysis
  • Compact and durable design for easy installation
  • Wide range of measurement options for diverse power monitoring
  • Easy data transfer for efficient analysis
  • Long battery life for extended monitoring
  • Robust software for data analysis and visualization
(0)
Call for price
  • Isolated input, DCCT input for safe and accurate measurements.
  • 3 channels for simultaneous measurement of AC/DC currents.
  • 60 A maximum input current with derating, and up to ±200 A peak within 20 ms.
  • 2 V/50 A output voltage for easy measurement.
  • Terminal block with safety cover for secure connections.
  • Operating temperature range of 0°C to 40°C and humidity of 80% RH or less.
  • Power supply from Power Analyzers for reliable operation.
(0)
Call for price
  • High-accuracy power measurement for a wide range of applications.
  • IEC-compliant harmonic measurement and flicker analysis.
  • Supports up to 8 input units for flexible measurement configurations.
  • Wide measurement frequency band from DC to 5 MHz.
  • Fast data update rate of 1 ms, 10 ms, 50 ms, or 200 ms.
  • Accurate measurement with high-resolution sampling and low error rates.
  • Compact and rugged design for reliable operation in harsh environments.