Hioki

(0)
Call for price
  • Connectable instruments: Memory HiLogger LR8450 (Designed for use with plug-in units only), Memory HiLogger LR8450-01 (Wireless LAN model)
  • Operating temperature and humidity: -10°C to 50°C, 80% RH or less (no condensation)
  • Storage temperature and humidity: -20°C to 60°C, 80% RH or less (no condensation)
  • Vibration resistance: JIS D 1601:1995 5.3(1), Class 1A (passenger vehicle) equivalent
  • Included accessories: Instruction manual × 1, mounting screw × 2
  • Input terminals: D-sub 9 pin MALE × 2
  • Operation mode: Supports switching between receive mode and measured value output mode
  • Receive mode: No. of measurement channels: Max. 500 channels (max. 500 signals)
  • Measured values output mode: Convert LR8450 measured values and output them as CAN frames
  • Protocols supported: CAN (ISO11898), CAN FD (ISO11898), CAN FD (non-ISO)
  • Physical layer: ISO11898 (High Speed)
(0)
Call for price
  • STRAIN UNIT U8554 for precise strain measurements
  • Connectable instruments: Memory HiLogger LR8450 and LR8450-01
  • Operating temperature: -10°C to 50°C, 80% RH or less
  • Number of input channels: 5 ch
  • Input terminals: Push-button type terminal block (5 terminals per channel)
  • Measurement target: Voltage, Strain
  • Strain gauge transducer: Balanced differential input, Simultaneous sampling of all channels
(0)
Call for price
  • High-speed voltage measurement with 5 isolated channels
  • Resolution options: 100 mV, 200 mV, 1 V, 2 V, 10 V, 20 V, 100 V, and 1-5 V
  • Operating temperature: -10°C to 50°C, 80% RH or less
  • Connectable instruments: Memory HiLogger LR8450 and LR8450-01
  • Number of input channels: 5 ch (for voltage only)
  • Input terminals: M3 screw-type terminal block (2 terminals per channel)
  • Vibration resistance: JIS D 1601:1995 5.3(1), Class 1A (passenger vehicle) equivalent
  • Accessories: Instruction manual and mounting screw
(0)
Call for price
  • Connectable instruments: Memory HiLogger LR8450 (Designed for use with plug-in units only), Memory HiLogger LR8450-01 (Wireless LAN model)
  • Operating temperature and humidity: -10°C to 50°C, 80% RH or less (no condensation)
  • Number of input channels: 30 ch (Able to set voltage, temperature using the thermocouple, and humidity for each channel)
  • Input terminals: Push-button type terminal block (2 terminals per channel)
  • Measurement target: Voltage, temperature using the thermocouple, and humidity
  • Input type: Scanning by semiconductor relays
  • Voltage measurement (resolution): 10 mV f.s. (500 nV), 20 mV f.s. (1μV), 100 mV f.s. (5μV), 200 mV f.s. (10μV), 1 V f.s. (50μV), 2 V f.s. (100μV), 10 V f.s. (500μV), 20 V f.s. (1 mV), 100 V f.s. (5 mV), 1-5 V f.s. (500μV)
  • Temperature measurement (thermocouple): K: -100.00℃ to 1350.0℃, J: -100.00℃ to 1200.0℃, E: -100.00℃ to 1000.0℃, T: -100.00℃ to 400.0℃, N: -100.00℃ to 1300.0℃, R: 0.00℃ to 1700.0℃, S: 0.00℃ to 1700.0℃, B: 400.0℃ to 1800.0℃, C: 0.00℃ to 2000.0℃
(0)
Call for price
  • Connectable instruments: Memory HiLogger LR8450 (Designed for use with plug-in units only)
  • Memory HiLogger LR8450-01 (Wireless LAN model)
  • Operating temperature and humidity: -10°C to 50°C, 80% RH or less (no condensation)
  • Storage temperature and humidity: -20°C to 60°C, 80% RH or less (no condensation)
  • Vibration resistance: JIS D 1601:1995 5.3(1), Class 1A (passenger vehicle) equivalent
  • Number of input channels: 15 ch (Able to set voltage, temperature using the thermocouple or RTD, humidity, and resistance for each channel)
  • Input terminals: Push-button type terminal block (4 terminals per channel)
(0)
Call for price
  • 15 channels for voltage, temperature, and humidity measurement
  • 10 mV to 100 V voltage measurement resolution
  • Thermocouple temperature measurement from -100.00℃ to 2000.0℃
  • Connectable instruments including Memory HiLogger LR8450 and LR8450-01
  • Compact design with M3 screw-type terminal block
  • Operating temperature from -10°C to 50°C
  • Storage temperature from -20°C to 60°C
(0)
Call for price
  • Upgrade your Hioki ST9000 with the latest discharge detection technology.
  • Enhance your electrical safety standards with our reliable and accurate upgrade.
  • Discover the benefits of the ST9000 discharge detection upgrade.
  • Improve your electrical measurement capabilities with our expert upgrade solution.
  • Get the most out of your Hioki ST9000 with our discharge detection upgrade.
  • Stay ahead of the curve with the latest electrical safety standards.
  • Trust Mohammad Mahdi Electronics for your electrical measurement needs.
  • Experience the difference with our Hioki ST9000 discharge detection upgrade.
(0)
Call for price
  • Leak current measurement for electrical safety testing
  • True rms measurement for accurate current values
  • Compliance with various international standards
  • Automatic test and data storage capabilities
  • Compact design for easy handling
  • Wide range of measurement modes
  • High accuracy and reliability
(0)
Call for price
  • True rms measurement for accurate current values.
  • Leak current measurement for electrical safety standards compliance.
  • Measurement modes for voltage and safety conductor current.
  • Standards compliance for medical and electrical equipment.
  • Measurement ranges for DC, AC, and AC+DC modes.
  • Measurement accuracy for current measurement.
  • Interfaces for external I/O, medical device relay output, and USB 1.1.
(0)
Call for price
  • Insulation resistance testing with DC voltage method
  • Measurement range from 25 V to 1000 V
  • Basic accuracy of ±2 % rdg. ±5 dgt.
  • Fast and slow measurement speeds available
  • Internal memory for up to 10 saved items
  • Comparator setting for upper and lower limit values
  • RS-232C interface for external control and judgment result
(0)
Call for price
  • High-precision DC signal source for a wide range of applications
  • Constant voltage and current output for precise testing
  • Thermoelectric power generation for accurate temperature measurements
  • 20-step automatic generation for efficient testing
  • Compact and durable design for reliable performance
  • Wide range of output options for versatility
  • Easy-to-use interface for simplified testing
  • High-quality construction for long-lasting performance
(0)
Call for price
  • Max. voltage: 1,000 V DC
  • Resistor value: 1 M to 10,000 MΩ in 24 points
  • Dimensions: 270mm (10.63in) W × 90mm (3.54in)H × 195mm (7.68in)D
(0)
Call for price
  • Non-contact CAN sensor for detecting CAN signals without physical contact.
  • Capacitive-coupled signal detection method for reliable signal detection.
  • AVS/AVSS-compliant cables for secure signal transmission.
  • Compact design for easy integration into various applications.
  • Wide operating temperature range for use in harsh environments.
  • USB bus power for convenient power supply.
  • High-speed signal detection for fast and accurate data acquisition.
(0)
Call for price
  • Dimensions: 215 mm (8.46 in) W × 78 mm (3.07 in)H × 165 mm (6.50 in)D
  • Lead length: 75 cm (2.46 ft)
(0)
Call for price
  • Dimensions: 215 mm (8.46 in) W × 78 mm (3.07 in)H × 165 mm (6.50 in)D
  • Lead length: 75 cm (2.46 ft)
(0)
Call for price
  • Dimensions: 215 mm (8.46 in) W × 78 mm (3.07 in)H × 165 mm (6.50 in)D
  • Lead length: 75 cm (2.46 ft)
(0)
Call for price
  • Dimensions: 215 mm (8.46 in) W × 78 mm (3.07 in)H × 165 mm (6.50 in)D
  • Lead length: 75 cm (2.46 ft)
(0)
Call for price
  • Measures surface and volume resistance with high accuracy.
  • φ 100 mm (3.94 in) × 223 mm (8.78 in) compact design for easy handling.
  • 2.5 kg (88.2 oz) lightweight and portable.
  • 1 m (3.28 ft) cable length for convenient use.
  • Comes with instruction manual, counter-electrode with integrated stand, protective stand, carrying case, short bar, and counter-electrode connection cable.
  • Perfect for electrical safety testing and maintenance.
(0)
Call for price
  • Hioki SM7860-68 is a POWER SOURCE UNIT designed for use with the Super MΩ HiTester SM7810.
  • It applies voltage to an MLCC (Multilayer Ceramic Capacitor).
  • The unit features generation accuracy and output voltage accuracy of ±2% of set value ± 0.5 V (with no load).
  • Inter-channel error is ± 0.01 V or less (between outputs on the same line with no load).
  • The unit supports GP-IB, RS-232C, and EXT I/O interfaces.
  • It is powered by 100 V AC (SM7860-51 to -58) or 220 V AC, 50/60 Hz, 860 VA (SM7860-61 to -68).
  • The unit measures 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D and weighs 47 kg (1657.9 oz).
  • Accessories include a power cable, instruction manual, and operating precautions.
(0)
Call for price
  • Supported device: Super MΩ HiTester SM7810
  • Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
  • Generation accuracy: High precision
  • Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
  • Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
  • Interfaces: GP-IB, RS-232C, EXT I/O
  • Power supply: 100 V AC or 220 V AC, 50/60 Hz, 860 VA
  • Dimensions and mass: 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 47 kg (1657.9 oz)
(0)
Call for price
  • Supported device: Super MΩ HiTester SM7810
  • Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
  • Generation accuracy: High-precision power source unit
  • Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
  • Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
  • Interfaces: GP-IB, RS-232C, EXT I/O
  • Power supply: 100 V AC or 220 V AC, 50/60 Hz, 860 VA
  • Dimensions and mass: 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 47 kg (1657.9 oz)
(0)
Call for price
  • Power Supply Unit for Hioki SM7810
  • Super MΩ HiTester compatible
  • ±2% output voltage accuracy
  • ±0.01 V inter-channel error
  • GP-IB, RS-232C, EXT I/O interfaces
  • 100 V AC or 220 V AC power supply
  • 860 VA power supply capacity
  • Dimensions: 425 mm W × 249 mm H × 581 mm D
  • Weight: 47 kg
(0)
Call for price
  • Supported device: Super MΩ HiTester SM7810
  • Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
  • Generation accuracy: High-precision power source unit
  • Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
  • Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
  • Interfaces: GP-IB, RS-232C, EXT I/O
  • Power supply: 100 V AC or 220 V AC, 50/60 Hz, 860 VA
  • Dimensions and mass: 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 47 kg (1657.9 oz)
(0)
Call for price
  • Supported device: Super MΩ HiTester SM7810
  • Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
  • Generation accuracy: High-precision power source unit
  • Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
  • Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
  • Interfaces: GP-IB, RS-232C, EXT I/O
  • Power supply: 100 V AC or 220 V AC, 50/60 Hz, 860 VA
  • Dimensions and mass: 425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 47 kg (1657.9 oz)