Amprobe RS-3 PRO CAT IV 300 A Analog Clamp Meter
The Amprobe RS-3 PRO is a durable, reliable, and easy-to-use analog clamp meter that is well-suited for demanding electrical work in extreme environments. Its safety rating, measurement capabilities, and user-friendly design make it a popular choice among professionals in the field.
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Amprobe RS 3 PRO
The Amprobe RS-3 PRO is a rugged and reliable analog clamp meter designed for demanding electrical applications. With its CAT IV 600 V safety rating, this meter is suitable for use in high-risk environments where users may be exposed to high voltages.
Key Features
- Measures AC current up to 300 A
- Measures AC voltage up to 600 V
- Measures resistance and continuity
- Pointer lock function to secure the needle during transportation
- Easy-to-read rotary scale
- Operates without batteries for measuring amps and volts
- Works well in extreme temperatures from 5°F to 122°F
Durability and Reliability
The Amprobe RS-3 PRO is known for its durability and longevity. Many users have reported using the same meter for years, with one reviewer mentioning that their father’s old Amprobe meter was handed down to them. This speaks to the robust construction and reliable performance of the RS-3 PRO.
Ease of Use
With its intuitive rotary scale and pointer lock feature, the RS-3 PRO is easy to use for both experienced professionals and novice users. The meter’s ability to operate without batteries for current and voltage measurements is a significant advantage, as it eliminates the need to worry about battery life in the field.
Versatility
The Amprobe RS-3 PRO is suitable for a wide range of electrical applications, from testing generators to troubleshooting street lighting circuits. One reviewer mentioned using the analog meter to follow cable faults, as it can detect spikes in the circuit before the breaker trips, which may not be visible on a digital meter.
specifications
| General | |
| Display | Analog scales with clamping needle |
| Dimension | 243 x 102 x 41 mm (10.3 x 4.0 x 1.6 in.) |
| Weight | 0.455 kg (1.0 lb.) |
| Jaw opening /Conductor diameter | 41mm (1.64″) max |
| Power Supply | |
| Volt/ amp | powered by circuit under test |
| Ohm | 1.5 V AAA battery (ANSI/NEDA-24A, IEC LR03) |
| Low Battery | Below approx. 1.2 V |
| Environmental | Indoor operation; below 2000m (6,562ft) |
| Operating Temperature | -15°C to 50°C (5°F to 122°F) ; < 80% |
| Storage Temperature | -20ºC to 60ºC (-4ºF to 140ºF), < 80% R.H. (with battery removed) |
| Temperature Coefficient | nominal 0.15 x (specified accuracy)/ ºC @ 0ºC – 18ºC or 28ºC – 40ºC (32°F – 64°F or 82°F – 104°F) |
| Safety LVD | Category IV – 600 Volts ac |
| Meets EN60101-1:2001; EN61010-2-032(2002; pollution degree : II; class 2 | |
| EMC | EN 61326-1:2006 |
| Electrical | [23ºC ± 5ºC (73ºC ± 9ºC)] |
| AC Voltage (50/60 Hz) | |
| Ranges | 150 / 300 / 600 Vrms |
| Accuracy | ± 3 % of Full Scale. |
| Input Impedance | 1.5 MΩ |
| OL Protection | 600 V ac rms |
| AC Amp (50/60 Hz) | |
| Ranges | 6 / 15 / 40 / 100 /600 Arms |
| Accuracy | ± 3 % of Full Scale |
| Ohms | |
| Range | 1000 ohms; 25 Ohms mid scale |
| Accuracy | ± 3 degrees of Arc |
| Open Circuit voltage | 1.5v |
| Short circuit Current | xx mA |
| OL Protection | (F 0.5 A / 1000 V, size 6 x 32 mm IR fast blow ceramic) |