Eurotron SWG100 BIOGAS-Biogas Analyser
For applications involving installations at Waste Water Treatment Plants (WWTP) or landfill sites, the SWG100 BIOEX, which is ATEX ZONE II certified, is a more suitable solution. If your application is for small-sized farm-based anaerobic digesters and you need only 1-2 sampling points without a continuous monitoring system, the SWG100 BIOcompact is ideal.
The SWG100 BIOGS analyzer continuously measures O2, CO2%, CH4%, and H2S, detecting gas changes in real-time. In certain processes, biogas quality can change rapidly, and CHP’s gas engines need a live signal to adapt to these variations.
The SWG100 BIOGS features an integrated gas cooler, a peristaltic pump, and AUTO CAL functions, ensuring high accuracy, repeatability, and stable readings under all process conditions, even with extremely wet gases, such as biogas sampling before heating treatment. The gas cooler also maximizes sensor protection by preventing moisture buildup in the gas stream.
Eurotron SWG100 BIOGAS Key Features
- Purpose built fixed gas analyser
- Accurately measure 02, CO2%, CH4% as standard
- Additional measurements for H2S, H2, and CO
- H2S sensor protection via solenoid valve and purge pump
- Dual H2S sensors for low and high levels
- 1-10 Sampling points
- Integrated Peltier Gas Cooler and condensate pump for automatic moisture removal
- Continuous monitor as standard
- Auto Calibration function as standard
- User Calibration function
- Up to 40 x 4-20 mA outputs and inputs, individually configurable
- Gas Analyser system alarm and gas alarms/notification
- Up to 20 alarms contact relay outputs
- Standard Modbus RTU digital communication
- Optional Profibus, Profinet and Ethernet industrial interfaces
- Data and event logging on SD card
- Optional Cabinet Heater for cold climate operation
- Exceptional on-site service support from our specialized team of engineers
Eurotron SWG100 BIOGAS Specifications
Sample Points | 1-10 | ||||
Measurements | |||||
Gas | Range | Accuracy∗ | Resolution | Type | Method |
O2% | 0-25 % | ± 0.2% Vol | 0.01% Vol | EC | Continuous |
CH4% | 0-100% | ± 0.3% Vol 0-10 % ± 0.5% Vol 10-65 % ± 1.5% Vol 65-100 % |
0.01% Vol | NDIR | Continuous |
CO2% | 0-100% | ± 0.3% Vol 0-10 % ± 0.5% Vol 10-65 % ± 1.5% Vol 65-100 % |
0.01% Vol | NDIR | Continuous |
H2S | 0-4000 ppm | ± 5 ppm | 1 ppm | EC | Continuous or Sample |
H2S | 0-50 ppm | ± 5 ppm | 1 ppm | EC | Continuous or Sample |
H2S | 0-200 ppm | ± 5 ppm | 1 ppm | EC | Continuous or Sample |
H2S | 0-10.000 ppm | ± 50 ppm | 1 ppm | EC | Continuous or Sample |
H2 | 0-1 % | ± 20 ppm | 1 ppm | EC | Continuous |
CO (H2 compensated) | 0-20000 ppm | ± 20 ppm | 1 ppm | EC | Continuous |
Barometric Pressure | 850-1150 mbar | n/a | 1 mbar | Piezo | Continuous |
Calculated Values | CV gross/net 0-50 MJ3, MJ/Kg | ||||
Display | 3.5″ TFT color display, backlight | ||||
Keyboard | Tactile with password protected menu | ||||
Output communications/Industrial Interfaces | |||||
Analouge | up to 40 x 4-20 mA outputs/input individually configurable | ||||
Alarms | 1 x system alarm and up to 20 alarms relay output , free contact 24 VDC/5A | ||||
Digital | Modbus RTU as standard, optional Ethernet, profinet, profibus DP and wed enable remote access | ||||
Data logging | Internal memory and SD card | ||||
Event Log | Record of Alarm/event to SD card | ||||
Gas Sample | |||||
Gas Inlet | Stainless steel gas gas fittings with 1/8″ ID Thread | ||||
Gas Cooler | Integrated high efficiency gas cooler with condensate pump for moisture removal | ||||
Filter | Teflon Particulate filter, internal housing in Viton | ||||
Flow | 40-60 l/hr | ||||
Pressure | Sample pressure from -100 to 300 mbar | ||||
Safety | |||||
Internal Gas Leak detector ( optional) | |||||
Standard Ventilated cabinet with continuos fan monitoring | |||||
Standard Stainless Steel flow orifice restriction | |||||
Sample Gas Shut-down solenoid valve | |||||
Physical | |||||
Dimension | 700x600x210 (H x W x D) wall mounting ( bracket supplied) | ||||
Weight | App: 25 KG | ||||
Case Material | Special coated Aluminium | ||||
IP Protection | IP 54 | ||||
Operating Temperature | +5 to 45 °C ( -10 to 45 °C with optional heater) | ||||
Heater | Optional Cabinet Heater 200 W | ||||
Mains/Power | Universal 100-240 VAC/ 47..63 Hz, 90W -( 300 W with cabinet heater) | ||||
Notes | ∗ After Calibration and do not include calibration gas accuracy ∗∗ Specifications might change due to product improvement with-out prior communication |
Specifications
Eurotron SWG100 BIOGAS Specifications
Sample Points | 1-10 | ||||
Measurements | |||||
Gas | Range | Accuracy∗ | Resolution | Type | Method |
O2% | 0-25 % | ± 0.2% Vol | 0.01% Vol | EC | Continuous |
CH4% | 0-100% | ± 0.3% Vol 0-10 % ± 0.5% Vol 10-65 % ± 1.5% Vol 65-100 % |
0.01% Vol | NDIR | Continuous |
CO2% | 0-100% | ± 0.3% Vol 0-10 % ± 0.5% Vol 10-65 % ± 1.5% Vol 65-100 % |
0.01% Vol | NDIR | Continuous |
H2S | 0-4000 ppm | ± 5 ppm | 1 ppm | EC | Continuous or Sample |
H2S | 0-50 ppm | ± 5 ppm | 1 ppm | EC | Continuous or Sample |
H2S | 0-200 ppm | ± 5 ppm | 1 ppm | EC | Continuous or Sample |
H2S | 0-10.000 ppm | ± 50 ppm | 1 ppm | EC | Continuous or Sample |
H2 | 0-1 % | ± 20 ppm | 1 ppm | EC | Continuous |
CO (H2 compensated) | 0-20000 ppm | ± 20 ppm | 1 ppm | EC | Continuous |
Barometric Pressure | 850-1150 mbar | n/a | 1 mbar | Piezo | Continuous |
Calculated Values | CV gross/net 0-50 MJ3, MJ/Kg | ||||
Display | 3.5″ TFT color display, backlight | ||||
Keyboard | Tactile with password protected menu | ||||
Output communications/Industrial Interfaces | |||||
Analouge | up to 40 x 4-20 mA outputs/input individually configurable | ||||
Alarms | 1 x system alarm and up to 20 alarms relay output , free contact 24 VDC/5A | ||||
Digital | Modbus RTU as standard, optional Ethernet, profinet, profibus DP and wed enable remote access | ||||
Data logging | Internal memory and SD card | ||||
Event Log | Record of Alarm/event to SD card | ||||
Gas Sample | |||||
Gas Inlet | Stainless steel gas gas fittings with 1/8″ ID Thread | ||||
Gas Cooler | Integrated high efficiency gas cooler with condensate pump for moisture removal | ||||
Filter | Teflon Particulate filter, internal housing in Viton | ||||
Flow | 40-60 l/hr | ||||
Pressure | Sample pressure from -100 to 300 mbar | ||||
Safety | |||||
Internal Gas Leak detector ( optional) | |||||
Standard Ventilated cabinet with continuos fan monitoring | |||||
Standard Stainless Steel flow orifice restriction | |||||
Sample Gas Shut-down solenoid valve | |||||
Physical | |||||
Dimension | 700x600x210 (H x W x D) wall mounting ( bracket supplied) | ||||
Weight | App: 25 KG | ||||
Case Material | Special coated Aluminium | ||||
IP Protection | IP 54 | ||||
Operating Temperature | +5 to 45 °C ( -10 to 45 °C with optional heater) | ||||
Heater | Optional Cabinet Heater 200 W | ||||
Mains/Power | Universal 100-240 VAC/ 47..63 Hz, 90W -( 300 W with cabinet heater) | ||||
Notes | ∗ After Calibration and do not include calibration gas accuracy ∗∗ Specifications might change due to product improvement with-out prior communication |
Related Products
Testo 330i Advanced Set -Flue Gas Analyzer Set
Rated 5.00 out of 5
(1)
In stock
AED 8,366 (excl.VAT)
Testo 300 Longlife kit 2 with printer – Flue gas analyzer
Rated 5.00 out of 5
(1)
In stock
AED 8,200 (excl.VAT)
Testo 350 – Analysis Box for Exhaust Gas Analysis Systems
Rated 5.00 out of 5
(1)
In stock
AED 6,125 (excl.VAT)
Testo 315-3 CO and CO2 meter for ambient measurements
Rated 5.00 out of 5
(1)
In stock
AED 4,263 (excl.VAT)