Fluke 123B/EU/S Industrial ScopeMeter + SCC 20MHz
- True-rms measurements on voltage and current
- Oscilloscope bandwidth 20 MHz
- Peak detection modes for transient analysis
- Current clamp input with scale factors
- Temperature and decibel measurement capability
- Phase measurement between two inputs
- Power analysis for 125B model
- Secure Purchase
- Fast Delivery
- Genuine Guarantee
- Online Payment
Description
The Fluke 123B/EU/S Industrial ScopeMeter is a versatile handheld oscilloscope designed for field service technicians and engineers who need to troubleshoot complex electrical systems. Combining the functionality of a digital multimeter with the visualization capabilities of a 20 MHz bandwidth oscilloscope, this instrument excels at capturing transient events, validating power quality, and diagnosing intermittent faults in industrial environments. Its rugged, IP40-rated housing ensures durability on the job site, while the large, high-contrast display provides clear readings even in bright conditions.
Fluke 123B/EU/S Key Features
This ScopeMeter delivers comprehensive measurement capabilities across voltage, current, frequency, and beyond. With true-rms accuracy on AC and DC coupled signals, users can trust the readings on non-linear loads. The device features multiple input channels for simultaneous voltage and current monitoring, peak detection modes to capture maximum and minimum values, and frequency oscilloscope bandwidth of DC to 20 MHz (-3 dB). Additional features include temperature decoding, decibel measurements, and phase analysis, making it a comprehensive tool for various electrical maintenance tasks.
- DC voltage ranges: 500 mV, 5 V, 50 V, 500 V, 750 V
- True-rms AC and AC+DC voltage measurements
- Oscilloscope bandwidth: DC to 20 MHz (-3 dB) (123B)
- Peak detection modes: Max, Min, and pk-to-pk
- Current clamp inputs with scale factors from 0.1 mV/A to 10 mV/mA
- Temperature measurement with optional probe
- Decibel measurement referenced to 600 Ω or 50 Ω
- Phase measurement between inputs A and B
Who Needs the Fluke 123B/EU/S?
Field service technicians will appreciate the Fluke 123B/EU/S for its portability and quick setup time when responding to emergency calls. The ability to capture waveform transients and perform true-rms measurements makes it ideal for troubleshooting motor drives, variable frequency drives, and power distribution systems. Maintenance engineers rely on this instrument for routine preventive maintenance, as it simplifies the process of checking voltage waveforms, measuring current with clamps, and verifying frequency stability without needing multiple separate devices.
Electricians working on industrial control panels benefit from the current clamp input options, allowing them to measure branch circuit loads without disconnecting wires. The decibel function is particularly useful for telecommunications and audio-visual installations, while the phase measurement capability aids in troubleshooting three-phase motor operation. Buyers and procurement teams specifying test equipment will find the 123B/EU/S offers a compelling combination of ScopeMeter functionality and multimeter versatility in a single, compact package.
Fluke 123B/EU/S Applications
In industrial settings, the Fluke 123B/EU/S excels at troubleshooting variable frequency drives and motor control circuits, where capturing speed fluctuations and voltage transients is critical. The instrument’s oscilloscope bandwidth of 20 MHz makes it suitable for switching power supply analysis and high-frequency noise diagnosis. For HVAC technicians, the temperature measurement function (with optional probe) simplifies system commissioning and troubleshooting of heating and cooling equipment.
Field service applications include validating solar inverter output, testing battery bank health, and diagnosing intermittent faults in complex machinery. The decibel measurement feature assists audio engineers in verifying signal levels, while the phase analysis helps identify power factor issues in commercial building electrical systems. Its versatility makes it a go-to tool for any professional who needs to see, measure, and verify electrical signals in the field.
Why Buy Fluke 123B/EU/S from Mohammad Mahdi Electronics?
Mohammad Mahdi Electronics is the trusted source for genuine Fluke test and measurement equipment in the UAE. When you purchase the Fluke 123B/EU/S from MME, you receive a factory-backed instrument with the full manufacturer warranty and certification. Our knowledgeable team can provide product demonstrations and application support to ensure you select the right tool for your specific needs. We maintain stock of popular Fluke models and offer prompt delivery across the region, minimizing downtime for your operations.
Choose Mohammad Mahdi Electronics for authentic Fluke products, competitive pricing structures, and dedicated customer service. Our commitment to quality means you can rely on the accuracy and durability of every instrument we supply, supported by technical expertise you can trust.
CTA paragraph varying company name naturally…
Fluke 123B/EU/S Specifications
| Input A and input B | ||
| DC voltage (VDC) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy | ±(0.5% +5 counts) | |
| Common mode rejection (CMRR) | >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz | |
| Full scale reading | 5000 counts | |
| True-rms voltages (V ac and V ac+dc) | ||
| Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
| Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V ac+dc) | ±(1% +10 counts) |
| 1 Hz to 60 Hz (V ac) | ±(1% +10 counts) | |
| Accuracy for 5% to 100% of range (AC or dc coupled) | 60 Hz to 20 kHz | ±(2.5% +15 counts) |
| DC rejection (only VAC) | >50 dB | |
| Common mode rejection (CMRR) | >100 dB @ dc | |
| >60 dB @ 50, 60, or 400 Hz | ||
| Full scale reading | 5000 counts, reading is independent of any signal crest factor. | |
| Peak | ||
| Modes | Max peak, Min peak, or pk-to-pk | |
| Ranges | 500 mV, 5 V, 50 V, 500 V, 2200 V | |
| Accuracy | Accuracy Max peak or Min peak | 5% of full scale |
| Accuracy Peak-to-Peak | 10% of full scale | |
| Full scale reading | 500 counts | |
| Frequency (Hz) | ||
| Ranges | 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz | |
| 124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz | ||
| Frequency range | 15 Hz (1 Hz) to 50 MHz in continuous autoset | |
| Accuracy @1 Hz to 1 MHz | ±(0.5% +2 counts) | |
| Full scale reading | 10,000 counts | |
| RPM | ||
| Max reading | 50.00 kRPM | |
| Accuracy | ±(0.5% +2 counts) | |
| Duty cycle (PULSE) | ||
| Range | 2% to 98% | |
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Pulse width (PULSE) | ||
| Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset | |
| Full scale reading | 1000 counts | |
| Amperes (AMP) | ||
| With current clamp | Ranges | Same as V dc, V ac, V ac+dc, or PEAK |
| Scale factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA | |
| Accuracy | Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty) | |
| Temperature (TEMP) with optional temperature probe | ||
| Range | 200 °C/div (200 °F/div) | |
| Scale factor | 1 mV/°C and 1 mV/°F | |
| Accuracy | As V dc (add temp. probe uncertainty) | |
| Decibel (dB) | ||
| 0 dBV | 1 V | |
| 0 dBm (600 Ω /50 Ω) | 1 mW referenced to 600 Ω or 50 Ω | |
| dB on | V dc, V ac, or Vac+dc | |
| Full scale reading | 1000 counts | |
| Crest factor (CREST) | ||
| Range | 1 to 10 | |
| Full scale reading | 90 Counts | |
| Phase | ||
| Modes | A to B, B to A | |
| Range | 0 to 359 degrees | |
| Resolution | 1 degree | |
| Power (125B only) | ||
| Configurations | 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only) | |
| Power factor (PF) | Ratio between watts and VA range – 0.00 to 1.00 | |
| Watt | RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes) | |
| Full scale reading | 999 counts | |
| VA | Vrms x Arms | |
| Full scale reading | 999 counts | |
| VA reactive (var) | √((VA)2-W2) | |
| Full scale reading | 999 counts | |
| Vpwm | ||
| Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs | |
| Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency | |
| Accuracy | As Vrms for sinewave signals | |
Datasheet
Datasheet
User Manual
User Manual
Reviews (0)
You must be logged in to post a review.