Megger VLF Sine Wave 62 kV- Test And Diagnostic System

(1 customer review)

Short Description:

MEGGER VLF Key Features :

  • Performs cable withstand testing, cable diagnosis, and sheath fault pinpointing
  • Smallest and lightest unit on the market in its class
  • Automatic result interpretation as per the latest IEEE 400.2 standard
  • Easy field operation with no need for an external computer
Product purchase
SKU: 4842
Brand:Megger

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

19 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
Description

The Megger VLF Sine Wave 62 kV Test and Diagnostic System is a state-of-the-art solution for the testing and analysis of medium voltage cables. This system is designed to offer not only robustness and portability but also high performance with its integrated tan delta diagnostic feature. The compact design makes it ideal for use in various field conditions, ensuring reliability and ease of transport.

The multifunctionality of the 62 kV tester is one of its standout features. It supports both Very Low Frequency (VLF) and Direct Current (DC) testing methodologies. Moreover, this system is equipped to handle sheath testing and fault pinpointing effectively when paired with the step voltage probe ESG NT/NT2. This capability is particularly valuable for locating faults in cable sheaths, which is critical for maintaining the integrity and functionality of underground cables.

An optional internal tan delta feature further enhances the tester’s utility by allowing it to evaluate both the integrity and condition of the cables. This is crucial for preventative maintenance and ensuring the longevity of cable infrastructure. The smart VLF system is designed to automatically adjust the test frequency according to the cable length, which facilitates reliable testing of cables up to 25 km in length, even for those rated at 35 kV.

One of the key advantages of the VLF Sine Wave 62 kV system is its independence from external computers for field operations. It comes equipped with intuitive operating software and substantial internal memory, which allows for the automatic evaluation and storage of all test data. This feature simplifies the testing process and enhances productivity on-site.

Data transfer and report generation are streamlined with the system’s connectivity options. Whether through a USB port or an upcoming wireless connection to mobile devices, transferring datasets is straightforward. The included PC software, MeggerBook Lite, assists in processing these datasets into comprehensive reports. Additionally, the device itself provides options for reviewing all measurements either immediately after testing or at a later time, offering flexibility in data management and analysis.

MEGGER VLF Specifications:

  • VLF sine wave :0 … 44 kVRMS / 0 … 62 kVp
  • DC voltage: ± 0 … 62 kV
  • VLF rectangular voltage: 0 … 62 kV
  • Accuracy :± 1 %
  • Resolution:0.1 kV
  • Source output current :0 … 40 mA
  • Accuracy :± 1 %
  • Resolution:10 μA
  • Frequency range:0.01 Hz … 0.1 Hz autom. frequency adjustment
  • Output load: 1 μF @ 0,1 Hz at 44 kVRMS 10 μF maximum test capacity
  • Measuring frequency: 0.01 … 0.1Hz
  • Measuring range: 10-4…100
  • Accuracy: 10-4
  • Resolution:10-5
  • Sheath testing :0 … 5 kV, 0 … 10 kV, 0 … 20 kV DC 0 … 5 kV, 0 … 10 kV, 0 … 20 kV DC
  • Sheath fault pinpointing:Pulse rate 0.5:1, 1:2, 1:3, 1:4 and 1.5:0.5
  • Safety: autom. discharging of the test object
  • Input voltage:100 V … 264 V, 50/60 Hz, 2000 VA
  • Duty cycle: continuous
  • Internal memory: For at least 1000 measurements
  • Dimensions (W x H x D): 544 x 520 x 416 mm
  • Weight: 59 kg
  • Protection class:IP 21
  • Operating temperature: – 20 °C … + 55 °C
  • Storage temperature: – 20 °C … + 70 °C
datasheet

datasheet

Data Sheet

Specifications

Specifications

Specification Value
VLF Sine Wave 0 … 44 kVRMS / 0 … 62 kVp
DC Voltage ± 0 … 62 kV
VLF Rectangular Voltage 0 … 62 kV
Accuracy ± 1 %
Resolution 0.1 kV
Source Output Current 0 … 40 mA
Frequency Range 0.01 Hz … 0.1 Hz automatic frequency adjustment
Output Load 1 μF @ 0.1 Hz at 44 kVRMS 10 μF maximum test capacity
Measuring Frequency 0.01 … 0.1Hz
Measuring Range 10-4…100
Sheath Testing 0 … 5 kV, 0 … 10 kV, 0 … 20 kV DC
Sheath Fault Pinpointing Pulse rate 0.5:1, 1:2, 1:3, 1:4 and 1.5:0.5
Safety Automatic discharging of the test object
Input Voltage 100 V … 264 V, 50/60 Hz, 2000 VA
Duty Cycle Continuous
Internal Memory For at least 1000 measurements
Dimensions (W x H x D) 544 x 520 x 416 mm
Weight 59 kg
Protection Class IP 21
Operating Temperature – 20 °C … + 55 °C
Storage Temperature – 20 °C … + 70 °C
Reviews (1)
5
1 review
1
0
0
0
0

1 review for Megger VLF Sine Wave 62 kV- Test And Diagnostic System

Clear filters
  1. Silas

    It has high accuracy

Add a review