Megger TDR2000-3 time domain reflectometer

Short Description:

Megger TDR2000-3 and TDR2010-ADVANCED DUAL CHANNEL TDR designed for the location of faults communication and pilot cables and some power supplies the TDR2000/3 and TDR2010 are tough.

Product purchase
SKU: 4917 Category:
Brand:Megger

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

10 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE

Megger TDR2000-3 and TDR2010-ADVANCED DUAL CHANNEL TDR

Megger TDR2000-3 is designed to locate faults in communication cables and drivers as well as certain power supplies, the TDR2000/3 and TDR2010 are powerful. They’re CAT IV 150V rated and IP54 dust and weather-resistant, so they’re ready to go in the real world.

The Megger TDR2000/3 and TDR2010 dual-channel enhanced time-domain reflectometers have been designed to locate faults in communications and guide cables as well as certain power sources. They are rugged, CAT IV rated up to 150V, and IP54 dust and weather-resistant making them ideal for fieldwork.

Features such as Auto setup assist the novice in getting useful traces fast while the AUTO Find function assists in the interpretation of the traces. For the more expert user, there is the ability to manually override the auto function permitting fine tuning to enable the identification of hard-to-determine faults.

  • IP54 rating for working in the field
  • ‘Auto setup’ mode for an instant, easy use
  • ‘AutoFind’ and ‘FindEnd’ functions help you find the fault fast
  • Trace tagging allows a name to be saved with the trace
  • Distance-dependent gain counteracts signal attenuation
  • Step function improves the detection of near-end faults

fault locator time domain reflectometer:

Megger’s built-in AutoFind mode enables quick fault identification. Pressing the AutoFind key automatically adjusts the range and gain, and positions the cursor to the first major event on the cable. Press the AutoFind key again and the cursor will move to the next detected noise.

megger tdr2000/3 user manual:  please check the datasheet.

related products

MEGGER KMK8 ,Megger TDR2050,megger tdr2050 user manual,  megger tdr1000/3p, megger cfl535g user manual, megger 2003 507

Megger TDR2000-3 and TDR2010-ADVANCED DUAL CHANNEL TDR specifications:

  • GENERAL
  • Range
    Up to 20000 m with a minimum resolution of 0.1 m
    (Maximum range dependent on cable type)
    m                   ft                           ns
    10                 30                          125
    25                 80                          250
    50                 160                        500
    100               320                        100
    250               800                       2500
    500             1600                       5000
    1000           3200                      10000
    2500          8000                      25000
    5000          16000                    50000
    10000        32500                    100000
    20000       65000                    200000
  • Resolution: 1% of the range
  • Input protection: This instrument complies with IEC61010- 1 to protect the user in the event of connection to living systems. TDR2050 is rated at 600 V CAT IV whilst all other models are rated at 150 V CAT IV. TDR2050 is specifically designed to allow use on energized systems up to the rated voltage. All models are designed for use on de-energized systems and Megger fused leads must be used on power cables and fused leads must be used if the potential voltage between terminals could exceed 300 V or when connected to CATIV systems.
  • Output pulse: Up to 20 volts peak to peak into the open circuit. Pulse widths are determined by range, cable, and model used.
  • Power down: User programmable auto power off timer 1, 5, 10 mins or never
  • Battery: Li-ion rechargeable battery
  • Battery charge time: 6 hours at 0 °C to 40 °C
  • Battery life: 12 hours typical
  • Safety: These instruments comply with IEC61010-1 for connections to live systems up to 150 V CAT IV or 300 V CAT III (TDR2000/3 and 2010 only). TDR2050 is rated at 600 V CAT IV. Fused leads must be used if the voltage between terminals exceeds 300 V. Compliant with EN60950-1, EN61010-1, UN38.3, and EN62133.
  • Velocity factor:  Variable from 0.2 to 0.99 in steps of 0.01.
  • MECHANICAL
  • IP rating: The instrument is designed for use indoors or outdoors and is rated to IP54.
  • Case: ABS
  • Dimensions: 290 mm (11.4 in) x 190 mm (7.5 inches) x 55 mm (2.2 inches)
  • Weight: 1.7kg (3.8lbs)
  • Connectors: Four 4mm-safety terminals and two F connectors. Other standard pushon adapters will fit. F connectors not available on TDR2050

datasheet

Data Sheet

specifications

Technical Specifications

Category Details
Range Up to 20000 m with a minimum resolution of 0.1 m (Maximum range dependent on cable type)
Range Measurement
  • 10 m (30 ft, 125 ns)
  • 25 m (80 ft, 250 ns)
  • 50 m (160 ft, 500 ns)
  • 100 m (320 ft, 100 ns)
  • 250 m (800 ft, 2500 ns)
  • 500 m (1600 ft, 5000 ns)
  • 1000 m (3200 ft, 10000 ns)
  • 2500 m (8000 ft, 25000 ns)
  • 5000 m (16000 ft, 50000 ns)
  • 10000 m (32500 ft, 100000 ns)
  • 20000 m (65000 ft, 200000 ns)
Resolution 1% of the range
Input Protection This instrument complies with IEC61010-1, rated at 150 V CAT IV (600 V CAT IV for TDR2050). Designed for use on energized systems up to the rated voltage.
Output Pulse Up to 20 volts peak to peak into open circuit. Pulse widths vary by range, cable, and model.
Power Down User programmable auto power off timer (1, 5, 10 mins or never)
Battery Li-ion rechargeable battery, 6 hours charge time, 12 hours typical battery life
Velocity Factor Variable from 0.2 to 0.99 in steps of 0.01
IP Rating IP54, suitable for indoor and outdoor use
Case ABS
Dimensions 290 mm x 190 mm x 55 mm
Weight 1.7 kg (3.8 lbs)
Connectors Four 4mm safety terminals, two F connectors (not available on TDR2050)