Fluke 381 Remote Display AC/DC Clamp Meter with iFlex
Short Description:
Fluke 381 Key features :
- Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement for added flexibility without interference with measurement accuracy
- The removable magnetic display of Fluke 381 meter can be conveniently mounted where it is easily seen
- iFlex® Flexible Current Probe of fluke multimeter 381 expands the measurement range to 2500 A AC
- CAT IV 600 V, CAT III 1000 V
- Integrated low pass filter and state-of-the-art signal processing allow for use in noisy electrical environments while providing stable readings
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing protective equipment
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 381 True RMS Clamp Meter
The Fluke 381 True RMS Clamp Meter is a versatile and advanced tool designed for electricians and technicians to perform a wide range of electrical measurements.
Now, one technician can complete tasks that previously required two. Clamp the Fluke 381 around a conductor, take the display off, and move around the space to handle controls or take off safety gear while keeping an eye on real-time readings. The iFlex® Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward-sized conductors, and disorganized wires.
Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex buy
fluke 381 specifications :
fluke 381 specifications are
AC Current via Jaw | |
---|---|
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) |
Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 |
AC Current via Flexible Current Probe | |
---|---|
Range | 999.9 A / 2500 A (45 Hz – 500 Hz) |
Resolution | 0.1 A / 1 A |
Accuracy | 3% ± 5 digits |
Crest Factor (50/60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
DC Current | |
---|---|
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2% ± 5 digits |
AC Voltage | |
---|---|
Range | 600 V /1000 V |
Resolution | 0.1 V / 1 V |
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) |
DC Voltage | |
---|---|
Range | 600.0 V /1000 V |
Resolution | 0.1 V / 1 V |
Accuracy | 1% ± 5 digits |
Frequency – Via Jaw | |
---|---|
Range | 5.0 – 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5% ± 5 digits |
Trigger Level | 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A |
Frequency via Flexible Current Probe | |
---|---|
Range | 5.0 to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5% ± 5 digits |
Trigger Level | 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A |
Resistance | |
---|---|
Range | 600 Ω/6 kΩ/60 kΩ |
Resolution | 0.1 Ω/1 Ω/10 Ω |
Accuracy | 1% ± 5 digits |
Mechanical Specifications
Size (L x W x H) | 277 x 88 x 43 mm (55 mm for remote unit) |
Weight | 350 g |
Jaw Opening | 34 mm |
Flexible Current Probe Diameter | 7.5 mm |
Flexible Current Probe Cable Length (head to electronics connector) | 1.8 m |
Environmental Specifications
Operating Temperature | -10°C to +50°C |
Storage Temperature | -40°C to +60°C |
Operating Humidity | Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) |
Operating Altitude | 2,000 meters |
Storage Altitude | 12,000 meters |
EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
Wireless Frequency | 2.4 GHz ISM Band 10 meter range |
Safety Compliance
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. Double Insulation Clearance: Per IEC 61010-2-032 Double Insulation Creepage: Per IEC 61010-1 |
for more information and buy fluke clamp amp meter visit mme-ae website.
AC voltage range/resolution/accuracy | |
---|---|
DC voltage range/resolution/Accuracy | |
AC current range/resolution/Accuracy | |
DC current range/resolution/Accuracy |
999.9 A/0.1 A/2 % ± 5 digits |
Resistance Range/resolution/Accuracy |
60,000 Ω/0.1 Ω/ % ± 5 digits |
Frequency range/resolution/Accuracy |
500 Hz/0.1 Hz/ 0.5 % ± 5 digits |
Dimensions |
277 mm x 88 mm x 43 mm |
Weight |
350 g |
Operating temperature |
-10 °C to 50 °C |
Storage temperature |
-20 … 60 °C |
Continuity test |
√ |
Data Hold |
√ |
Diode test |
√ |
MIN - MAX |
√ |
True RMS |
√ |
low pass filter |
√ |
Backlight |
√ |
datasheet
Access Fluke 381 user manual,datasheet and safetysheet to get detailed information on how to set up, operate, and maintain your device efficiently.
specifications
AC Current via Jaw | |
---|---|
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) |
Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 |
AC Current via Flexible Current Probe | |
---|---|
Range | 999.9 A / 2500 A (45 Hz – 500 Hz) |
Resolution | 0.1 A / 1 A |
Accuracy | 3% ± 5 digits |
Crest Factor (50/60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
DC Current | |
---|---|
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2% ± 5 digits |
AC Voltage | |
---|---|
Range | 600 V /1000 V |
Resolution | 0.1 V / 1 V |
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) |
DC Voltage | |
---|---|
Range | 600.0 V /1000 V |
Resolution | 0.1 V / 1 V |
Accuracy | 1% ± 5 digits |
Frequency – Via Jaw | |
---|---|
Range | 5.0 – 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5% ± 5 digits |
Trigger Level | 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A |
Frequency via Flexible Current Probe | |
---|---|
Range | 5.0 to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5% ± 5 digits |
Trigger Level | 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A |
Resistance | |
---|---|
Range | 600 Ω/6 kΩ/60 kΩ |
Resolution | 0.1 Ω/1 Ω/10 Ω |
Accuracy | 1% ± 5 digits |
Mechanical Specifications
Size (L x W x H) | 277 x 88 x 43 mm (55 mm for remote unit) |
Weight | 350 g |
Jaw Opening | 34 mm |
Flexible Current Probe Diameter | 7.5 mm |
Flexible Current Probe Cable Length (head to electronics connector) | 1.8 m |
Environmental Specifications
Operating Temperature | -10°C to +50°C |
Storage Temperature | -40°C to +60°C |
Operating Humidity | Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) |
Operating Altitude | 2,000 meters |
Storage Altitude | 12,000 meters |
EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
Wireless Frequency | 2.4 GHz ISM Band 10 meter range |
Safety Compliance
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. Double Insulation Clearance: Per IEC 61010-2-032 Double Insulation Creepage: Per IEC 61010-1 |
2 reviews for Fluke 381 Remote Display AC/DC Clamp Meter with iFlex
Clear filtersYou must be logged in to post a review.
Related Products
In stock
Samuel –
Very nice meter, good quality as expected by Fluke
James Adams –
The cables I purchased are durable and handle high loads without any issues.