Fluke 378 FC Voltage AC/DC Clamp Meter
Short Description:
Fluke 378 FC Voltage AC/DC Clamp Meter Key features :
- Measure voltage and current with your clamp jaw
- Faster, safer testing – all without touching a live wire – using FieldSenseâ„¢ technology
- Power quality indicator shows whether equipment or power line is faulty
- Complete 3-phase voltage and current tests in 3 quick steps
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
19
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 378 FC Voltage AC/DC Clamp Meter
The Fluke 378 FC Voltage AC/DC Clamp Meter is an advanced tool designed to enhance safety and efficiency in electrical testing. This high-performance meter allows users to measure both voltage and current directly through the clamp jaw, providing accurate readings without the need for additional testing equipment.
One of the standout features of the Fluke 378 FC is its use of FieldSenseâ„¢ technology. This innovative technology enables faster and safer testing by allowing measurements to be taken without touching live wires. By utilizing FieldSenseâ„¢, the Fluke 378 FC ensures that users can conduct tests with confidence, reducing the risk of electrical shock and improving overall safety.
In addition to its advanced measurement capabilities, the Fluke 378 FC also includes a power quality indicator. This feature helps users quickly identify whether equipment or power lines are faulty, providing valuable insights into the health of the electrical system and facilitating proactive maintenance.
The Fluke 378 FC is also designed to streamline the testing of three-phase systems. It simplifies the process of completing 3-phase voltage and current tests in just three quick steps. To obtain accurate readings, simply clip the black test lead to any electrical ground, place the clamp jaw around the conductor, and view the reliable and precise voltage and current values displayed on the meter.
The 378 FC clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 FC will detect and display power quality issues, relating to current, voltage, power factor, or any combination of the three. MME AE is a renowned importer and distributor of fluke current clamp meter in Dubai and various other countries, providing the most competitive prices in the market.
Fluke 378 FC Voltage AC/DC Clamp Meter Specifications
- AC Current( Jaw) Range : 999.9 A
- AC Current( Flexible Current Probe )Range : 2500 A
- DC Current Range: 999.9 A
- AC Voltage Range: 1000 V
- DC Voltage Range: 600.0 V, 1000 V
- mV dc Range : 500.0 mV
- Amps Frequency ( Jaw ) Range: 5.0 Hz to 500.0 Hz
- Amps Frequency(Flexible Current Probe) Range:5.0 Hz to 500.0 Hz
- Resistance Range : 60.00 kΩ ,6000 Ω,600.0 Ω
- Capacitance Range: 1000 μF
- Size (L x W x H) : 274 mm x 86 mm x 47 mm
- Weight (with Batteries): 463 g
- Operating Temperature: -10 °C to 50 °C
- Storage Temperature: -40 °C to 60 °C
- Frequency Range: 2405 MHz to 2480 MHz
Related Products
Here, we are referring to some products as related products
- Fluke 368 FC
- Fluke 393 FC
Specifications
General Maximum Voltage between any Terminal and Earth Ground | 1000 V |
Battery Type | 2 AA IEC LR6 alkaline |
Battery Life | 200 hours |
Display | Dual readout |
Automatic Power Off | 20 minutes |
Electrical Specifications
AC Current: Jaw | |
---|---|
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2 % ±5 digits (45 Hz to 66 Hz) |
Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2 % for C.F. >2 |
AC Current: Flexible Current Probe | |
---|---|
Range | 2500 A |
Resolution | 1 A (≤2500 A) 0.1 A (≤999.9 A) |
Accuracy | 3 % ±5 digits (5 Hz to 500 Hz) |
Crest Factor (50/60Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. >2 |
DC Current | |
---|---|
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2 % ±5 digits [1]When using the ZERO function to compensate for offsets |
AC Voltage: Field Sense | |
---|---|
Range | 1000 V |
Resolution | 1 V (≤1000V) |
Accuracy | ≤4/0 AWG: 3 % ±5 digits (45 Hz to 66 Hz) ≥4/0 AWG: 5 % ±5 digits (45 Hz to 66 Hz) |
AC Voltage: Test Leads | |
---|---|
Range | 600.0 V 1000 V |
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) |
Accuracy | 1 % ±5 digits (20 Hz to 500 Hz) |
DC Voltage | |
---|---|
Range | 600.0 V 1000 V |
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) |
Accuracy | 1 % ±5 digits |
mV dc | |
---|---|
Range | 500.0 mV |
Resolution | 0.1 mV |
Accuracy | 1 % ±5 digits |
Amps Frequency: Jaw | |
---|---|
Range | 45 Hz to 66 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % ±5 digits |
Trigger Level | 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥ 5 A 100 Hz to 500 Hz, ≥ 10 A |
Amps Frequency: Flexible Current Probe | |
---|---|
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % ±5 digits |
Trigger Level | 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A |
Resistance | |
---|---|
Range | 60.00 kΩ 6000 Ω 600.0 Ω |
Resolution | 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60.00 kΩ) |
Accuracy | 1 % ±5 digits |
Capacitance | |
---|---|
Range | 1000 μF |
Resolution | 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) |
Accuracy | 1 % ±4 digits |
Mechanical Specifications
<tr
Size (L x W x H) | 274 mm x 86 mm x 47 mm |
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0