Megger KMK8 BRIDGE TDR

2 Comments
  • Meets IEC 61010 safety standards for high voltage environments
  • Active Bridge mode for precision R and C measurements
  • Time Domain Reflectometer (TDR) for low impedance faults
  • Passive Wheatstone Bridge for high interference voltages
  • Graaf Fault Locator for water-soaked cables
  • Handheld and versatile for telecom industry use
Terms of sending goods ›
  • In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE
  • For out-of-stock items, delivery may take 2 to 4 business weeks.
SKU: 4904 Category:
Brand:Megger

Show Price on WhatsApp

In stockDelivers in 2-3 business days.
Description

Megger KMK8 Bridge TDR

The MEGGER KMK8 Bridge TDR is a comprehensive and versatile instrument designed for the telecommunication industry, facilitating the evaluation and fault location on telecommunication cables. This handheld device integrates multiple technologies, making it highly effective for both qualitative assessment and precise fault localization in varying cable conditions.

Features of the KMK8

  • Active Bridge: This feature enables high precision resistance (R) and capacitance (C) measurements, along with DC and AC fault location. It is particularly effective in environments with low interference voltages, allowing for more accurate fault detection.
  • Passive Wheatstone Bridge: For scenarios where interference voltages are high, the passive Wheatstone bridge configuration comes into play. This setup is designed to handle and accurately locate faults in such challenging environments.
  • Graaf Fault Locator: The KMK8 uses the Graaf method in conjunction with an active slave at the far end for precise fault location, especially effective on cables that are thoroughly water-soaked and exhibit high and intermittent interference voltages.
  • Time Domain Reflectometer (TDR): The TDR component is crucial for identifying low impedance faults and cross-talk issues between pairs, enhancing the ability to pinpoint exact locations of faults.
Data Sheet

Data Sheet

Data Sheet

specifications

specifications

Technical Specifications

Category Specification
Power Supply Internal rechargeable NiMH battery pack
Operating Time Approx. 8 hours (without backlight)
Charging Options From 100 … 240 V mains with the battery pack, mains adapter; from 12 V car battery with car adapter
Charging Time Less than 3 hours (fast charging mode)
Display 320 x 240 dot graphic LCD
Connectors
  • Connector for mains adapter: 2.1 / 5.5mm coax
  • L1 and L2 line connectors: 4 mm banana sockets
  • Ground connector: 4 mm banana socket
  • USB A: USB 1.1 host port for USB stick
  • USB B: USB 1.1 device port to connect PC
Over Voltage Protection
  • Between a and b or ground: 500 V DC, 350 V AC
  • Longitudinal voltage: 60 V AC
Ambient Temperature Ranges
  • Reference: 23 ± 5 °C, Rel. humidity 45% … 75%
  • Normal operation: 0 … +40 °C, Rel. humidity 30% … 75%
  • Limits of operation: -5 … +45 °C, Rel. humidity 5% … 95%
  • Storage and transport: -40 … +70 °C, Rel. humidity 95% at +45 °C
Memory
  • Memory for test results: 50
  • Memory for cable parameters: 50
Dimensions 224 x 160 x 75 mm
Weight Approx. 1.8 kg (including battery pack)