PCE-AQD 50A Environmental Meter
The PCE-AQD 50A Environmental Meter is vital for professionals monitoring air quality. Its multifunctional design and precision make it suitable for various applications. This meter aids technicians and researchers in maintaining optimal conditions and meeting health standards, providing accurate data for better decision-making and improved indoor and outdoor environments.
- CO² measurement range up to: 0 to 40000 ppm
- Relative humidity measurement range up to: 0 to 100 % RH
- Air pressure measurement range up to: 300 to 1250 hPa
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
- For out-of-stock items, delivery may take 2 to 4 business weeks.
Order Via phone number
Buy PCE-AQD 50A
The Environmental Meter PCE-AQD 50A is a versatile and essential instrument designed for professionals monitoring air quality and environmental conditions. This advanced meter is particularly valuable in various industries, including construction, HVAC, and environmental research, where maintaining optimal air quality is crucial. With its comprehensive measurement capabilities, the PCE-AQD 50A enables users to assess multiple environmental parameters effectively.
This meter is engineered to measure key air quality indicators such as particulate matter (PM), temperature, humidity, and carbon dioxide (CO2) levels. The PCE-AQD 50A helps professionals identify potential air quality issues and take corrective actions to ensure a safe and healthy environment by providing real-time data on these parameters. Its user-friendly interface and portable design make it an ideal tool for both fieldwork and laboratory settings.
PCE-AQD 50A Environmental Meter Key Features
The PCE-AQD 50A has several features that make it an ideal tool for battery testing. These include:
- Multifunctional Measurements: The PCE-AQD 50A can measure various environmental parameters, including PM2.5, PM10, temperature, humidity, and CO2 concentration. This multifunctionality allows users to obtain a comprehensive overview of air quality in one device.
- High Precision Sensors: Equipped with advanced sensors, the PCE-AQD 50A delivers accurate and reliable measurements. This precision is essential for professionals who need to monitor air quality closely.
- User-Friendly Display: The device features a clear LCD display that presents measurements in an easy-to-read format. This intuitive interface simplifies operation and enhances user experience.
- Data Logging Capability: The PCE-AQD 50A can store measurement data for later analysis. This feature is particularly useful for long-term monitoring projects or inspections requiring documentation.
- Compact and Portable Design: Weighing just a few kilograms, the meter is lightweight and easy to transport. Its compact design allows for convenient use in various settings, from indoor environments to outdoor locations.
- Durable Construction: Built to withstand the demands of everyday use, the PCE-AQD 50A features a robust casing that protects it from impacts and harsh conditions.
The PCE-AQD 50A Environmental Meter is essential for professionals focused on air quality monitoring. With its multifunctional capabilities, precision, and user-friendly design, it suits various applications. This advanced meter helps technicians and researchers maintain optimal environmental conditions and adhere to health standards, allowing for informed decisions based on accurate data and improving indoor and outdoor environments.
PCE-AQD 50A Specifications
The PCE-AQD 50A can measure CO2 gas concentrations up to 40000 ppm, with an accuracy of ±(40 ppm + 5% of Rd) within the range of 400 to 5000 ppm at 25 ºC / 77 ºF.
| CO² | |
| Measurement range up to | 0 … 40000 ppm |
| Resolution | 1 ppm |
| Accuracy | ±(40 ppm +5 % of Rd) @ 400 … 5000 ppm @ 25 ºC / 77 ºF |
| Relative humidity | |
| Measurement range up to | 0 … 80 % RH |
| Resolution | 0,1 % RH |
| Accuracy | ±1.5 % RH |
| Relative humidity | |
| Measurement range up to | 80 … 100 % RH |
| Resolution | 0,1 % RH |
| Accuracy | ±2 % RH |
| Air pressure | |
| Measurement range up to | 300 … 1250 hPa |
| Resolution | 0,1 hPa |
| Accuracy | ±50 hPa @ -20 … 75 ºC / 700 … 1100 hPa |
| Temperature | |
| Measurement range up to | 0 … 50 °C |
| Resolution | 0,1 °C |
| Accuracy | 0.15 |
| Temperature | |
| Measurement range up to | 0 … 20 °C |
| Resolution | 0,1 °C |
| Accuracy | ±0.15 ºC |
| Temperature | |
| Measurement range up to | 20 … 50 °C |
| Resolution | 0,1 °C |
| Accuracy | ±0.1 ºC |
| Temperature | |
| Measurement range up to | 32 … 60 °F |
| Resolution | 0,1 °F |
| Accuracy | ±0.15 ºF |
| Temperature | |
| Measurement range up to | 68 … 122 °F |
| Resolution | 0,1 °F |
| Accuracy | ±0.1 °F |
| General technical data | |
| Display type | E-paper |
| Display size | 2,7 Inch |
| Storage medium | Micro SD card |
| Storage capacity | 32 GB |
| Interface | USB-C |
| Operating time | 10 Month(s) |
| Operating time additional information | 10 months when measuring intervals are: |
| -temperature: 24 hours | |
| -ambient humidity: 24 hours | |
| -atmospheric pressure: 24 hours | |
| -CO2: 24 hours | |
| Alarm | optical, Acoustic |
| Menu language | English, Dutch, French, German, Italian, Polish, Spanish, Turkish |
| Protection class (device) | IP30 |
| Power supply | 5 V/1.5 A |
| Weight | 280 g |
| Operating conditions | 0 … 50 °C , 0 … 100 % RH |
| Storage conditions | -20 … 60 °C , 0 … 100 % RH |
Buy the PCE-AQD 50A Environmental Meter, essential for professionals monitoring air quality. With multifunctional features and high precision, it ensures compliance with health and safety standards. This advanced tool enables informed decision-making based on accurate data, promoting healthier indoor and outdoor environments.
Specifications
| CO² | |
| Measurement range up to | 0 … 40000 ppm |
| Resolution | 1 ppm |
| Accuracy | ±(40 ppm +5 % of Rd) @ 400 … 5000 ppm @ 25 ºC / 77 ºF |
| Relative humidity | |
| Measurement range up to | 0 … 80 % RH |
| Resolution | 0,1 % RH |
| Accuracy | ±1.5 % RH |
| Relative humidity | |
| Measurement range up to | 80 … 100 % RH |
| Resolution | 0,1 % RH |
| Accuracy | ±2 % RH |
| Air pressure | |
| Measurement range up to | 300 … 1250 hPa |
| Resolution | 0,1 hPa |
| Accuracy | ±50 hPa @ -20 … 75 ºC / 700 … 1100 hPa |
| Temperature | |
| Measurement range up to | 0 … 50 °C |
| Resolution | 0,1 °C |
| Accuracy | 0.15 |
| Temperature | |
| Measurement range up to | 0 … 20 °C |
| Resolution | 0,1 °C |
| Accuracy | ±0.15 ºC |
| Temperature | |
| Measurement range up to | 20 … 50 °C |
| Resolution | 0,1 °C |
| Accuracy | ±0.1 ºC |
| Temperature | |
| Measurement range up to | 32 … 60 °F |
| Resolution | 0,1 °F |
| Accuracy | ±0.15 ºF |
| Temperature | |
| Measurement range up to | 68 … 122 °F |
| Resolution | 0,1 °F |
| Accuracy | ±0.1 °F |
| General technical data | |
| Display type | E-paper |
| Display size | 2,7 Inch |
| Storage medium | Micro SD card |
| Storage capacity | 32 GB |
| Interface | USB-C |
| Operating time | 10 Month(s) |
| Operating time additional information | 10 months when measuring intervals are: |
| -temperature: 24 hours | |
| -ambient humidity: 24 hours | |
| -atmospheric pressure: 24 hours | |
| -CO2: 24 hours | |
| Alarm | optical, Acoustic |
| Menu language | English, Dutch, French, German, Italian, Polish, Spanish, Turkish |
| Protection class (device) | IP30 |
| Power supply | 5 V/1.5 A |
| Weight | 280 g |
| Operating conditions | 0 … 50 °C, 0 … 100 % RH |
| Storage conditions | -20 … 60 °C, 0 … 100 % RH |